Literature DB >> 12695883

Dynamic magnetic resonance imaging paragraph sign with radial scanning: a post-acquisition paragraph sign keyhole approach.

R Lethmate1, H Ratiney, F T A W Wajer, Y Crémillieux, D van Ormondt, D Graveron-Demilly.   

Abstract

A method - PA-keyhole - for 2D/3D dynamic magnetic resonance imaging with radial scanning is proposed. PA-keyhole exploits the inherent strong oversampling in the center of k-space, which contains crucial temporal information regarding contrast evolution. The method is based on: (1). a rearrangement of the temporal order of 2D/3D isotropic distributions of trajectories during the scan into subdistributions according to the desired time resolution, (2). a new post-acquisition keyhole approach based on the replacement of the central disk/sphere in k-space using data solely from a subdistribution, and (3). reconstruction of 2D/3D dynamic (time-resolved) images using 2D/3D-gridding with Pipe's approach to the sampling density compensation and 2D/3D-IFFT. The scan time is not increased with respect to a conventional 2D/3D radial scan of the same spatial resolution; in addition, one benefits from the dynamic information. The abilities of PA-keyhole and the sliding window techniques to restore simulated dynamic contrast changes are compared. Results are shown both for 2D and 3D dynamic imaging using experimental data. An application to in-vivo ventilation of rat lungs using hyperpolarized helium is demonstrated.

Entities:  

Mesh:

Year:  2003        PMID: 12695883     DOI: 10.1007/s10334-003-0003-y

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  23 in total

1.  A flexible view ordering technique for high-quality real-time 2DFT MR fluoroscopy.

Authors:  R F Busse; D G Kruger; J P Debbins; S B Fain; S J Riederer
Journal:  Magn Reson Med       Date:  1999-07       Impact factor: 4.668

2.  Dynamic imaging of hyperpolarized (3)He distribution in rat lungs using interleaved-spiral scans.

Authors:  M Viallon; Y Berthezène; V Callot; M Bourgeois; H Humblot; A Briguet; Y Crémillieux
Journal:  NMR Biomed       Date:  2000-06       Impact factor: 4.044

3.  Reconstructing MR images from undersampled data: data-weighting considerations.

Authors:  J G Pipe
Journal:  Magn Reson Med       Date:  2000-06       Impact factor: 4.668

4.  Sampling density compensation in MRI: rationale and an iterative numerical solution.

Authors:  J G Pipe; P Menon
Journal:  Magn Reson Med       Date:  1999-01       Impact factor: 4.668

5.  Lung air spaces: MR imaging evaluation with hyperpolarized 3He gas.

Authors:  E E de Lange; J P Mugler; J R Brookeman; J Knight-Scott; J D Truwit; C D Teates; T M Daniel; P L Bogorad; G D Cates
Journal:  Radiology       Date:  1999-03       Impact factor: 11.105

6.  Laser-polarized (3)He as a probe for dynamic regional measurements of lung perfusion and ventilation using magnetic resonance imaging.

Authors:  M Viallon; Y Berthezène; M Décorps; M Wiart; V Callot; M Bourgeois; H Humblot; A Briguet; Y Crémillieux
Journal:  Magn Reson Med       Date:  2000-07       Impact factor: 4.668

7.  Unifying linear prior-information-driven methods for accelerated image acquisition.

Authors:  J Tsao; B Behnia; A G Webb
Journal:  Magn Reson Med       Date:  2001-10       Impact factor: 4.668

8.  The gridding method for image reconstruction by Fourier transformation.

Authors:  H Schomberg; J Timmer
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

9.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

Authors:  J I Jackson; C H Meyer; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

10.  Spiral scanning with anisotropic field of view.

Authors:  K F King
Journal:  Magn Reson Med       Date:  1998-03       Impact factor: 4.668

View more
  3 in total

1.  Mapping and correcting hyperpolarized magnetization decay with radial keyhole imaging.

Authors:  Peter J Niedbalski; Matthew M Willmering; Scott H Robertson; Matthew S Freeman; Wolfgang Loew; Randy O Giaquinto; Christopher Ireland; Ronald G Pratt; Charles L Dumoulin; Jason C Woods; Zackary I Cleveland
Journal:  Magn Reson Med       Date:  2019-03-07       Impact factor: 4.668

2.  A comparison of radial keyhole strategies for high spatial and temporal resolution 4D contrast-enhanced MRI in small animal tumor models.

Authors:  Ergys Subashi; Everett J Moding; Gary P Cofer; James R MacFall; David G Kirsch; Yi Qi; G Allan Johnson
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

3.  Pulmonary perfusion imaging in the rodent lung using dynamic contrast-enhanced MRI.

Authors:  Nilesh N Mistry; James Pollaro; Jiayu Song; Ming De Lin; G Allan Johnson
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.