Literature DB >> 11283982

Myocardial wall tagging with undersampled projection reconstruction.

D C Peters1, F H Epstein, E R McVeigh.   

Abstract

Azimuthally undersampled projection reconstruction (PR) acquisition is investigated for use in myocardial wall tagging with MR using grid tags to provide increased temporal and spatial resolution. PR can provide the high-resolution images required for tagging with very few projections, at the expense of artifact. Insight is provided into the PR undersampling artifact, in the context of measuring myocardial motion with tags. For Fourier transform imaging, at least 112 phase-encodings must be collected to image tagging grids spaced 7 pixels apart. PR requires about 80 projections, a 1.4-fold reduction in scan time. Magn Reson Med 45:562-567, 2001. Published 2001 Wiley-Liss, Inc.

Mesh:

Year:  2001        PMID: 11283982      PMCID: PMC2396261          DOI: 10.1002/mrm.1076

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  Unaliasing by fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI.

Authors:  B Madore; G H Glover; N J Pelc
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Signal-to-noise ratio and signal-to-noise efficiency in SMASH imaging.

Authors:  D K Sodickson; M A Griswold; P M Jakob; R R Edelman; W J Manning
Journal:  Magn Reson Med       Date:  1999-05       Impact factor: 4.668

3.  Optimization of tag thickness for measuring position with magnetic resonance imaging.

Authors:  E Atalar; E R McVeigh
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

4.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

Authors:  J I Jackson; C H Meyer; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

Review 5.  Regional myocardial function.

Authors:  E McVeigh
Journal:  Cardiol Clin       Date:  1998-05       Impact factor: 2.213

6.  Common k-space acquisition: a method to improve myocardial grid-tag contrast.

Authors:  M Doyle; E G Walsh; R E Foster; G M Pohost
Journal:  Magn Reson Med       Date:  1997-05       Impact factor: 4.668

7.  Two-dimensional left ventricular deformation during systole using magnetic resonance imaging with spatial modulation of magnetization.

Authors:  A A Young; H Imai; C N Chang; L Axel
Journal:  Circulation       Date:  1994-02       Impact factor: 29.690

8.  Improved myocardial tagging contrast.

Authors:  S E Fischer; G C McKinnon; S E Maier; P Boesiger
Journal:  Magn Reson Med       Date:  1993-08       Impact factor: 4.668

9.  View sampling requirements in fan beam computed tomography.

Authors:  P M Joseph; R A Schulz
Journal:  Med Phys       Date:  1980 Nov-Dec       Impact factor: 4.071

10.  Quantitative assessment of myocardial viability after infarction by dobutamine magnetic resonance tagging.

Authors:  G Geskin; C M Kramer; W J Rogers; T M Theobald; D Pakstis; Y L Hu; N Reichek
Journal:  Circulation       Date:  1998-07-21       Impact factor: 29.690

View more
  16 in total

1.  High-resolution MRI of cardiac function with projection reconstruction and steady-state free precession.

Authors:  Dana C Peters; Daniel B Ennis; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

2.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

3.  Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views.

Authors:  Dana C Peters; Robert J Lederman; Alexander J Dick; Venkatesh K Raman; Michael A Guttman; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

4.  3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI.

Authors:  Dana C Peters; Daniel B Ennis; Pratik Rohatgi; Mushabbar A Syed; Elliot R McVeigh; Andrew E Arai
Journal:  J Magn Reson Imaging       Date:  2004-09       Impact factor: 4.813

5.  Reduced field of view and undersampled PR combined for interventional imaging of a fully dynamic field of view.

Authors:  Dana C Peters; Michael A Guttman; Alexander J Dick; Venkatesh K Raman; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

Review 6.  Advances in MRI tagging techniques for determining regional myocardial strain.

Authors:  Vinay M Pai; Leon Axel
Journal:  Curr Cardiol Rep       Date:  2006-02       Impact factor: 2.931

7.  Myocardial tagging with steady state free precession techniques and semi-automatic postprocessing--impact on diagnostic value.

Authors:  Thorsten R C Johnson; Nicole Bayrhof; Armin Huber; Joost P A Kuijer; Roger Luechinger; Olaf Dietrich; Dietrich Stoevesandt; Dorthe Pedersen; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2007-04-19       Impact factor: 5.315

Review 8.  Myocardial tagging by cardiovascular magnetic resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications.

Authors:  El-Sayed H Ibrahim
Journal:  J Cardiovasc Magn Reson       Date:  2011-07-28       Impact factor: 5.364

9.  Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: application to cardiac cine.

Authors:  Shu Li; Cheong Chan; Jason P Stockmann; Hemant Tagare; Ganesh Adluru; Leo K Tam; Gigi Galiana; R Todd Constable; Sebastian Kozerke; Dana C Peters
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

Review 10.  Quantification of regional myocardial wall motion by cardiovascular magnetic resonance.

Authors:  Kai Jiang; Xin Yu
Journal:  Quant Imaging Med Surg       Date:  2014-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.