Literature DB >> 18219115

Protein crystallography with a micrometre-sized synchrotron-radiation beam.

Rouslan Moukhametzianov1, Manfred Burghammer, Patricia C Edwards, Sebastien Petitdemange, Dimitri Popov, Maikel Fransen, Gregory McMullan, Gebhard F X Schertler, Christian Riekel.   

Abstract

For the first time, protein microcrystallography has been performed with a focused synchrotron-radiation beam of 1 microm using a goniometer with a sub-micrometre sphere of confusion. The crystal structure of xylanase II has been determined with a flux density of about 3 x 10(10) photons s(-1) microm(-2) at the sample. Two sets of diffraction images collected from different sized crystals were shown to comprise data of good quality, which allowed a 1.5 A resolution xylanase II structure to be obtained. The main conclusion of this experiment is that a high-resolution diffraction pattern can be obtained from 20 microm(3) crystal volume, corresponding to about 2 x 10(8) unit cells. Despite the high irradiation dose in this case, it was possible to obtain an excellent high-resolution map and it could be concluded from the individual atomic B-factor patterns that there was no evidence of significant radiation damage. The photoelectron escape from a narrow diffraction channel is a possible reason for reduced radiation damage as indicated by Monte Carlo simulations. These results open many new opportunities in scanning protein microcrystallography and make random data collection from microcrystals a real possibility, therefore enabling structures to be solved from much smaller crystals than previously anticipated as long as the crystallites are well ordered.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18219115      PMCID: PMC2467531          DOI: 10.1107/S090744490705812X

Source DB:  PubMed          Journal:  Acta Crystallogr D Biol Crystallogr        ISSN: 0907-4449


Introduction

Protein microdiffraction using monochromatic beams has become a routine tool at third-generation synchrotron-radiation sources (Cusack et al., 1998 ▶; Perrakis, Cipriani et al., 1999 ▶; Riekel, 2004 ▶; Riekel et al., 2005 ▶). Several protein structures have been solved using a 10 or 30 µm beam on much larger crystals and improved diffraction was obtained this way, most likely owing to a lack of long-range order in the large crystals (Dutzler et al., 2002 ▶; Xiao et al., 2003 ▶). A polyhedron-like protein structure was solved from 125 µm3 crystals by merging data from several crystals (Coulibaly et al., 2007 ▶). Beam sizes have reached the 5 µm scale using a combination of focusing and collimation optics, with illuminated crystal volumes per single exposure of less than 400 µm3, as shown for the case of bovine rhodopsin, which was refined to a resolution of 2.6 Å (Li et al., 2004 ▶). More recently, the structure of a thermally stabilized recombinant rhodopsin was solved using a 5 µm thick needle crystal using a diffraction volume of 125 µm3 per pattern (Standfuss et al., 2007 ▶). The same beam size allowed the solution of an amyloid fibre structure (eight amino acids) using a diffraction volume of about 40 µm3 (Riekel, 2004 ▶; Nelson et al., 2005 ▶). It has recently been suggested that a reduction of the dimension of a crystal in the horizontal scattering plane to a few micrometres should result in a reduction in secondary radiation damage owing to the high escape probability of the photoelectrons (Nave & Hill, 2005 ▶). The use of small crystals is an interesting and desirable avenue to explore in order to extend the lower limit of accessible crystal volumes, but has several consequences for beamline instrumentation. The beam size has to be reduced by focusing to the micrometre scale in order to increase the flux density. The sphere of confusion of the rotation axis at the sample position should be less than the beam size in order to keep the sample in the beam during data collection. Owing to the limiting radiation dose of crystals (Henderson, 1990 ▶), one also has to be able to distribute the overall dose by multiple exposures across a crystal or a number of small crystals by a combination of mapping and rotation (Riekel et al., 2005 ▶; Nave & Hill, 2005 ▶). In the extreme case, a random orientational distribution of crystallites could be exploited instead of an active rotation. In addition, the instrument has to be optimized for a low scattering background in order to maximize the signal-to-noise ratio of reflections as far as possible. However, the collimating system of the current generation of microgoniometers is not fully optimized for background reduction and has limited possibilities for scanning a sample through the beam (Riekel et al., 2005 ▶). The aim of this paper is to report on progress in using a focused micrometre-sized beam in combination with an optimized micro-collimating system developed for scanning micro-SAXS/WAXS experiments (Fig. 1 ▶; Riekel, 2000 ▶). Here, we demonstrate for the first time that it is possible to determine a high-resolution structure using diffraction patterns obtained from a 20 µm3 protein crystal volume for each pattern. A piezo-micromanipulator combined with an air-bearing rotation axis provided the precision required to centre the crystal in the micrometre-sized X-ray beam (Fig. 2 ▶).
Figure 1

Schematic design and distance indications of the undulator source and optics. A, low-β undulator source; B, primary slits; C, double Si(111) monochromator; D, secondary slits in front of a Kirkpatrick–Baez (KB) mirror; E1 and E2, KB mirrors; F: micromanipulator and goniometer. The size and divergence of the beam at the undulator source point and at the focal spot are symbolized by squares. The distance from the source and the beam divergence are indicated.

Figure 2

Schematic design of the goniometer setup during sample alignment. (a) Overall view; (b) close-up of the sample environment. Components: A, mirror chamber; B1, ionization chamber; B2, guard aperture support; B3, beam stop; C, cryoflow; D, microscope objectives; E, MAR 165 CCD; F, sample support; G, micromanipulator; H, xy sample stage; I1–I3, xyz sample positioner. For data collection the microscope is translated vertically into a home position and the MAR CCD is translated to a chosen distance from the sample.

In the current study, xylanase II crystals were selected to assess the applicability of a micrometre-sized beam to protein crystallography (Fig. 3 ▶). Xylanase depolymerizes xylan molecules into monomeric units that are used by bacteria and fungi, and xylanase producers are typically found in environments in which plant material is deposited (Torronen, Harkki et al., 1994 ▶; Torronen, Rouvinen et al., 1994 ▶). Recently, there has been interest in xylanases for the development of environmentally friendly technologies in the paper and pulp industry (Kulkarni et al., 1999 ▶; Polizeli et al., 2005 ▶). Bleaching paper pulps with xylanases is a commercial application for these enzymes (Clarke et al., 2000 ▶).
Figure 3

Crystal/beam relationship. (a) Large and small crystals used for data collection with dimensions of 180 × 180 × 30 and 20 × 20 × 70 µm, respectively; 1 µm beam spot. (b) Strategy for data acquisition. After every rotation, new material is present in the narrow beam channel. A small intentional misset (2–5 µm) of the rotation axis was introduced. During data collection this creates a cylinder around the rotation centre, with the multiply illuminated area lying on the surface of the cylinder. Consequently, this minimizes the inclusion of damaged crystal volume contributing to individual diffraction patterns during total exposure.

Xylanase II from the fungus Trichoderma reesei is readily available and can be crystallized rapidly, producing very well diffracting crystals. In this study, we show that a well defined high-resolution structure from xylanase II can be obtained with the 1 µm setup at the ESRF and we discuss how the beam geometry could be responsible for a possible reduction in radiation damage.

Methods

Microfocus setup

Experiments were performed at the ESRF ID13 beamline using an in-vacuum low-β undulator optimized for X-ray energies of about 13 keV (Fig. 1 ▶). The beam is shaped by water-cooled primary slits, monochromated to λ = 0.976 Å by a liquid-N2-cooled Si(111) double crystal and focused by crossed Pt-covered Si mirrors. While practically the full vertical beam was accepted, the horizontal beam size was reduced by about a factor of three using slits at the entrance of the Kirkpatrick–Baez (KB) mirror system in order to obtain an approximate matching of horizontal and vertical size and divergence at the focal spot. The beam intensity was monitored with a micro-ionization chamber in front of the sample. The exit of the ionization chamber is fitted with a 20 µm guard aperture, which removes stray radiation generated by the KB mirror. An additional 200 µm lead aperture is placed between the crystal and the exit of the ionization chamber to further improve the background on the detector. A combination of micro-apertures is also used for micro-small-angle scattering experiments (Riekel, 2000 ▶). An effective beam size of about 1 × 1 µm (measured at half-maximum) was determined by a knife-edge scan of the guard aperture at the focal spot position with a beam divergence of about 1hor × 0.35vert mrad (Fig. 1 ▶). Focusing by highly demagnifying KB mirrors is known to generate diffuse tails. However, we found no evidence for additional scattering in the diffraction patterns. However, the possible generation of consequences arising from such diffuse tails will have to be studied in the future in more detail. After the crystal, a micro-beamstop of lead is placed just outside the cryostream as close as possible to the crystal in order to reduce the background from air scattering of the primary beam. In such a setup the flux density at the sample within an ∼1 × 1 µm beam reaches up to 3 × 1010 photons s−1 µm−2. In view of the small beam size, a microgoniometer setup with a sphere of confusion smaller than the beam size and optimum sample observation was required (Fig. 2 ▶). We used a vertically oriented MICOS UPR160 air-bearing spindle (company specifications: 100 nm eccentricity; about 2.5 µrad wobble at the level of the rotation axis), a MICOS MT55 xy microstage and a Kleindiek MM3A micromanipulator carrying a Hampton Research magnetic base. The sample was located about 110 mm above the rotation-axis bearings, which introduces a rotational eccentricity of about 0.3 µm at the sample position. The microgoniometer setup was positioned by a large-stroke xyz stage. An Olympus microscope with motorized rotating turret looking upstream along the beam path on the focus position was used for sample alignment in the focal spot. The microscope was translated out of the beam for data collection by a vertical motorized stage. Alignment of the air-bearing spindle axis with the microbeam was achieved with a precision of about 1 µm by using fibre-diffraction patterns from the 20 µm nylon loop. The marked beam position was stable for the duration of the experiment. Beam and optical alignments of the crystal were carried out with a new software interface specifically designed for the scanning microgoniometer.

Crystallization

Xylanase (21 kDa) from T. longibrachiatum (previously known as T. reesei) was purchased from Hampton Research (HR7-106). The sample was diluted to 10 mg ml−1 in sterile-filtered deionized water, clarified by centrifugation at 12 000g for 15 min at 277 K and used immediately after preparation. 100 nl sitting-drop crystallizations were set up in an MRC UV transparent 96-well plate (Wilden; Molecular Dimensions) using an Innovadyne dispensing robot and incubated at 291 K. Plates were monitored for crystal formation with the MRC multiwavelength imaging system at 380 and 280 nm (Fig. 3 ▶ a). The crystal image at 280 nm showed strong UV absorption, but UV inspection did not affect diffraction quality. Crystals formed across a range of ammonium sulfate concentrations and varying pH values. The crystals used for this data collection were grown in 2 M ammonium sulfate, 100 mM MES pH 5.5 and 0.5 M MgCl2. Two different sized crystals were chosen from the same crystallization drop and frozen in liquid nitrogen with the addition of 20% glycerol in nylon loops (Hampton Research, HR8-126). The 180 × 180 × 30 µm (9.7 × 105 µm3) size of the larger crystal is very common for X-ray protein crystallography and the 20 × 20 × 70 µm (= 2.8 × 104 µm3) size of the smaller crystal is in the upper volume range of crystals typically used for microcrystallography at present (Riekel et al., 2005 ▶).

Diffraction data collection

Data were collected with exposure times of 1 s per image with 0.5° oscillations using a 1 µm beam with a beam divergence of 1 mrad horizontally and 0.35 mrad vertically (Fig. 1 ▶). Diffraction patterns were recorded on a MAR CCD 165 detector while the crystal was kept in a 100 K cryostream flow. The crystal-to-detector distance was determined to be 99.8 mm by calibration using Al2O3 powder. The large crystal diffracted well beyond 1.5 Å, but the actual resolution limit was not determined. For the small crystal, we set the limit to 1.5 Å, where there was a good signal-to-noise ratio for the outer reflections [I/σ(I) = 2.5]. 180° of data were collected from the large crystal. However, there was only enough time to collect 90° of data from the smaller crystal. The 1 µm beam (see §2.1) illuminates crystal volumes of 20–30 µm3. Accordingly, a high flux of about 3 × 1010 photons s−1 is needed to record a single diffraction image to high resolution. If conventional measurements were performed at such a high flux an accumulation of radiation damage would quickly occur within the illuminated volume, which in this case would be used for the recording of many images. In our case, however, each oscillation image measured with the microbeam exposes a fresh narrow channel of the crystal and therefore a high-quality pattern is obtained each time. Overlap was minimized by an intentional misset of the rotation axis (2–­5 µm). A cylinder around the rotation centre is created during data collection, with the multiply illuminated areas lying on the surface of the cylinder (Fig. 3 ▶ b). It is only important that the illuminated volume contributing to a single image does not suffer from too extensive a dose of X-rays. Excellent high-resolution diffraction patterns from both crystals were acquired with diffraction spots clearly visible at 1.5 Å using the unattentuated beam (Fig. 4 ▶).
Figure 4

Diffraction pattern of xylanase II. (a), (b), (c): Spot shapes for reflections of high, medium and low resolution, respectively, with different magnitude of counts. (d), (e), (f): Normalized standard profiles (background pixels, 0; peak pixels are shown as a histogram within the range {1–9, A–Z}) accumulated in MOSFLM from spots of several adjacent images within a certain detector area. The detector pixel size is 78.94 × 78.94 µm. The shape of low- and medium-resolution spots is mainly defined by the detector point-spread function. Average profiles do not adequately fit the individual spot shape for strong spots at low resolution, therefore in this resolution range integration by summation of pixels is superior to profile fitting. A weighted integration scheme described in the text was used to find the best compromise.

Results

Data processing

We collected complete data from the large crystal (>180°) with a completeness that was well within the recommended range at 99.9%; however, some reflections in the low-resolution range were overloaded and rejected. We decided to collect a large wedge of data from the much smaller crystal (Fig. 3 ▶ a) in order to compare data statistics. Because of time pressure, we were only able to collect 90° of data from the smaller crystal, but we did not intend to solve the structure from this data. The completeness for the small crystal was 86% for the inner and outer shell, which indicates that a full data set would have had excellent completeness. Finally, we combined the two data sets and obtained an exceptionally good completeness for all resolution shells. Data were processed with MOSFLM and SCALA (Collaborative Computational Project, Number 4, 1994 ▶). DPS autoindexing (Steller et al., 1997 ▶) in MOSFLM (Leslie, 1992 ▶) using data from single images as well as from several images clearly indicated a monoclinic Laue group for the crystals, with unit-cell parameters a = 40.57, b = 38.96, c = 57.46 Å, β = 110.75° for the smaller crystal and a = 40.57, b = 38.83, c = 57.34 Å, β = 110.61° for the larger crystal after cell-parameter refinement using two segments of data separated by 90°. The mosaic spread for both crystals was estimated to be 0.3°. Data were successfully integrated in MOSFLM while refining crystal, beam and detector parameters using the least-squares procedure for each image. Refined beam and detector parameters showed no significant variation within the whole data collection, demonstrating the stability of the position of the micrometre-sized beam at the detector. A slight gradual sliding of the crystal indicated by a change in crystal missetting angles during orientation refinement reached about 0.7° for a total ϕ range of 180°. This could well arise from small gradual shifts of the crystal mounting loop during crystal rotation owing to the magnetic junction to the goniometer or could be a consequence of a very small deviation of the angle between the spindle and beam from 90°, but is irrelevant for data processing. The extremely small beam size allows very sharp diffraction spots to be recorded; under experimental conditions, the spot shape on the image is mainly defined by the detector point-spread function. The actual spot size for low- and medium-resolution reflections, as estimated from the value of the mosaic spread, is well within the pixel size of the detector (79 µm) and therefore the profile of these spots is very similar over a wide range of resolution (Fig. 4 ▶). Only the profile of weaker high-resolution spots differs through the diffraction image and contains information about the mosaicity of the crystal and the degree of reflection partiality, which could be useful if the detector point-spread function was low and the pixel size was small. The average spot profiles accumulated from spots of several successive images in MOSFLM are very much the same for different detector regions. Taking these observations into account, we used a weighted integration scheme to optimally integrate the reflections. For strong reflections with insignificant random noise the use of average spot profiles for integration of reflection intensities (I prof) becomes slightly worse than summation integration (I sum), as indicated by R merge, which follows from the fact that the peak area spreads over only very few detector pixels (Figs. 4 ▶ c and 4 ▶ f). For weak reflections, the use of profile fitting is preferred since it is significantly better than summation integration with respect to the reduction of random noise (Figs. 4 ▶ a and 4 ▶ d). Finally, the intensity of reflection was set to the weighted sum of the profile-fitted intensity and summation-integration intensity in SCALA as followswhere the weight w = 1/[1 + (I sum/I mid)3] and I mid is the average intensity of all reflections. Comparison of scaling and merging in SCALA for two crystals shows that in the case of the larger crystal there is a substantial difference in diffraction strength between ‘face-on’ and ‘edge-on’ orientations of the crystal (up to a factor of ten); this is primarily a consequence of the plate-like crystal shape, which causes a large change in the X-ray channel volume irradiated by the microbeam. The same difference in diffraction strength would occur for a conventional beam roughly matching the crystal size. However, for the conventional beam the reason is the change in the cross-section of the X-ray beam contributing to the diffraction. Merging of scaled strong signal-to-noise reflections in the low-resolution range shows less agreement between symmetry-related reflections for the larger crystal (R merge = 0.057, 10–4 Å) than for the smaller one (R merge = 0.040, 10–4 Å). The data from both the large and the small crystals could be satisfactorily merged with improved completeness, especially at low resolution, and good multiplicity, because some overloaded reflections from the large crystal were measured correctly for the smaller crystal. A slight increase in R merge, which could arise from more data being merged or be a consequence of non-isomorphism, was observed. The final merging statistics, data redundancy and completeness for three data sets are shown in Table 1 ▶. The overall Wilson B factor is not changed, indicating no significant radiation damage.
Table 1

Data-collection and refinement statistics

Values in parentheses are for the highest resolution shell.

 Large crystalSmall crystalMerged data
Data collection
 Space groupP21P21P21
 Unit-cell parameters
   a (Å)40.5740.5740.57
   b (Å)38.8338.9638.89
   c (Å)57.3457.4657.40
  α (°)90.090.090.0
  β (°)110.61110.75110.75
  γ (°)90.090.090.0
 Resolution (Å)1.50 (1.50–1.54)1.50 (1.50–1.54)1.50 (1.50–1.54)
Rmerge0.066 (0.162)0.064 (0.354)0.084 (0.265)
I/σ(I)14.3 (7.1)10.1 (2.5)16.8 (6.8)
 Completeness (%)99.7 (99.9)86.8 (86.8)99.9 (100.0)
 Redundancy3.6 (3.4)2.2 (2.0)5.5 (5.3)
Refinement
 Resolution (Å)1.51.51.5
 No. of reflections267482233826925
Rwork/Rfree0.181/0.2030.185/0.1980.192/0.215
 No. of atoms
  Protein147214721472
  Water122122122
B factors (Å2)
  Protein11.411.511.5
  Water21.421.421.4
 Overall anisotropic B2)
   B11  1.34
   B22  0.27
   B33  −1.62
   B13  0.76
 R.m.s. deviations
  Bond lengths (Å)0.0050.0050.005
  Bond angles (°)1.41.41.4
Statistical analysis of the intensity distribution of diffraction data was performed with TRUNCATE (CCP4 suite) and showed no deviations from expected intensity distributions.

Refinement

The structure of xylanase II was solved by molecular replacement. Several structures of xylanase II from crystals belonging to different space groups have been deposited in the Protein Data Bank (Moiseeva & Allaire, 2004 ▶; Watanabe et al., 2006 ▶). The model selected for molecular replacement was a 2 Å resolution X-ray structure solved from a crystal form identical to that in the present work (Miyatake et al., 2006 ▶). Molecular replacement was performed using MOLREP (Collaborative Computational Project, Number 4, 1994 ▶; Vagin & Teplyakov, 1997 ▶). The structure from the PDB (entry 2d97) was reduced to a polyalanine model in order to decrease model bias and was used as a search model. Diffraction data in the resolution range 10–3 Å were used in the rotation and translation functions. A single distinct rotation-function peak was found and after a translation-function search the solution with the highest score, which was well above the others, was selected. Since xylanase II consists of 190 amino acids, there is only one molecule in the asymmetric unit, with 54% solvent content. The molecular-replacement solution for the polyalanine search model had an R factor of 0.461 for the larger crystal and 0.441 for the smaller one. Having data to 1.5 Å allowed us to successfully complete the molecular-replacement polyalanine model using the ARP/wARP suite in a mode alternating iterative building and refinement steps (Perrakis, Morris et al., 1999 ▶). Maximum-likelihood refinement cycles were performed in REFMAC and were combined with addition and deletion of atoms, updating the starting model in ARP (Murshudov et al., 1997 ▶). The initial polyalanine model was retraced and used only for guiding the autobuilding; therefore, model bias was under control. 5% of the data set was randomly chosen and used for cross-validation using R free. After only 20 refinement cycles in ARP/wARP a fairly complete model consisting of 176 residues with side chains for the larger crystal and R = 0.190, R free = 0.216 (175 residues, R = 0.195, R free = 0.239 for the smaller crystal) was obtained. The ARP/wARP model was completed using the graphics program O (Jones et al., 1991 ▶). Solvent molecules with displacement parameters lower than 35 Å2 were picked up from the difference density map. The structure was finally refined in CNS (Brünger et al., 1998 ▶). Several rounds of energy minimization were performed followed by individual temperature-factor refinement. Refinement statistics and geometry parameters of the model are presented in Table 1 ▶. The final model consists of 190 residues and 120 water molecules. All the residues are within allowed regions in the Ramachandran plot.

Discussion

In this study, we have used a 1 µm beam setup for the first time (Figs. 1 ▶ and 2 ▶) and have determined the structure of a well diffracting crystal of xylanase II (Fig. 3 ▶ a) to a resolution of 1.5 Å (Table 1 ▶). We studied the diffraction from an average-sized and a small crystal. The final electron-density maps after refinement against a combined data set (Table 1 ▶) showed excellent densities for all residues, with the exception of a few that are not ordered and are located on the protein surface. In particular, those residues that are highly susceptible to radiation damage showed clear density (Fig. 5 ▶). Increasing irradiation of protein crystals results in structural damage as follows: disulfide bridges break, glutamates and aspartates decarboxylate, tyrosine residues lose their hydroxyl group and methionines lose their C—S bond (Burmeister, 2000 ▶; Weik et al., 2000 ▶). However, there was no indication of specific radiation damage from our electron-density maps for these residues, as shown in Fig. 5 ▶. Furthermore, for the smaller crystal the temperature factors for the atoms of aspartate side chains were 12.50 Å2 on average and those for buried glutamates were 10.4 Å2 on average, which is not substantially different from the overall average B factor of 11.4 Å2 for protein side chains. Very similar B factors are observed for glutamates and aspartates in the larger crystal. No radiation damage is indicated for tyrosines and methionine. We did not intend to study radiation damage in detail or try to find the limiting dose; for this we would need to collect several data sets (Diederichs, 2006 ▶). We have demonstrated that with a high-brilliance 1 µm beam we can obtain a good high-resolution structure of a medium-sized protein.
Figure 5

Xylanase II structure. Left, secondary structure with selected residues; right, selected residues with 1.5 Å resolution σA-weighted 2F o − F c electron-density map contoured at 0.7 e Å−3 level. The excellent densities for beam-sensitive residues, for example glutamic acids, tyrosines and methionine, provide no evidence of radiation damage.

The experiments show that one can collect a diffraction pattern from an irradiated crystal volume of about 20 µm3 using an approximately 1 µm2 focused beam (∼3 × 1010 photons s−1 µm−2). As a consequence of rotation, new material will be constantly swept into the beam (Fig. 3 ▶ b), allowing the collection of a complete data set without significant radiation damage (as evident from the data statistics). In spite of the high irradiation dose, it was possible to obtain an excellent high-resolution map. The irradiated volume of a single exposure corresponds to about 2 × 108 unit cells and is therefore a factor of 5–15 smaller than the previously estimated limiting number of unit cells required to record a high-resolution diffraction pattern for 1° of rotation (Glaeser et al., 2000 ▶; Teng & Moffat, 2000 ▶, 2002 ▶). A comparison with selected other microdiffraction studies is shown in Fig. 6 ▶. Data from inorganic crystals have been added in order to demonstrate that crystals with smaller scattering power can be refined if radiation-damage problems can be neglected. The results on xylanase II suggest that the minimum crystal volumes and scattering power required to collect a high-resolution pattern have been overestimated in previous studies (Glaeser et al., 2000 ▶; Teng & Moffat, 2000 ▶, 2002 ▶). Crystals of lysozyme and bacteriorhodopsin of dimensions 100 × 100 × 20–40 µm diffracting to 1.5 and 2.1 Å with overall B factors comparable to that of xylanase and significantly higher were studied by Teng and coworkers and Glaeser and coworkers, respectively, at conventional synchrotron beamlines (Glaeser et al., 2000 ▶; Teng & Moffat, 2000 ▶, 2002 ▶).
Figure 6

Irradiated crystal volume (V cryst) scaled against scattering power (S) for a selected high-resolution single-crystal microdiffraction experiment (adapted from Riekel et al., 2005 ▶). The scattering power has been scaled to an average electron density: S = (F 000/V cell)2 × λ3 × V 32 cryst, where F 000 is the zero-order structure factor, V cell is the unit-cell volume, λ is the wavelength and V cryst is the crystal volume. For experiments with a beam size smaller than the crystal size, V cryst corresponds to the irradiated volume during a single exposure. The shaded zone indicates the previously predicted crystal-volume limit for protein crystallography. Open squares represent inorganic structures: 1, CaF2 (Burghammer, 1997 ▶); 2, kaolimite (Neder et al., 1996 ▶); 3, birnessite (Gaillot et al., 2003 ▶). Filled diamonds represent protein crystals: X, xylanase II; 4, rhodopsin (Li et al., 2004 ▶); 5, α-amylose (Popov et al., 2006 ▶); 6, amyloid-like fibrils (Nelson et al., 2005 ▶); 7, sensory rhodopsin II (Luecke et al., 2001 ▶); 8, bacteriorhodopsin (Pebay-Peyroula et al., 1997 ▶); 9, HIV-1 capsid protein (p24; Berthet-Colominas et al., 1999 ▶); 10: integrin α2β1-binding collagen peptide (Emsley et al., 2004 ▶).

The diameter of the beam used in the present study is sufficiently small that in calculating expected radiation damage the escape of photoelectrons from the scattering volume has to be taken into account (Nave & Hill, 2005 ▶). In the absence of radiation damage, the diffraction signal is expected to be proportional to the total number of incident photons and hence the number of photoelectrons generated in a given volume. Any reduction in radiation damage with decreasing beam diameter should be reflected by an increasing proportion of photoelectron energy being deposited outside the illuminated volume. To investigate, this a standard Monte Carlo program similar to that described by Joy (1995 ▶) was used to generate trajectories and associated energy-loss distributions. In the program, directional changes are given by elastic Rutherford scattering and energy loss is calculated using the continuous slowing-down approximation. For simplicity, averaged density, atomic charge and effective mean ionization potential were used. Photoelectrons are assumed to be generated randomly within a cylinder of length 20 µm. For simplicity, the initial energy was taken to be that of the incident photon, while the initial direction was generated either totally randomly or taking into account the polarization of the incident beam. The results of these calculations are summarized in Fig. 7 ▶, where a small beam-enhancement factor, given by the ratio of energy deposited in the illuminated volume for a effectively infinite-diameter beam to that of finite diameter but with the same total number of photoelectrons, is plotted as a function of beam diameter and initial energies of 8.1, 12.7 and 20 keV. For a given signal, it is therefore possible to deposit less total energy in the illuminated volume by using a smaller beam diameter or higher energy photon.
Figure 7

Calculated small beam enhancement, defined as the ratio of the total energy deposited in the crystal relative to that actually deposited in the beam volume, as a function of the beam diameter for incident X-ray energies of 8.1 keV (dashed line), 12.7 keV (unbroken line) and 15 keV (dotted line). The inset shows the calculated deposited energy density per generated 12.7 keV photoelectron as a function of radius for a 20 µm thick sample illuminated by a 1 µm diameter beam. On average, 12.1 keV is deposited in the whole crystal but only 1.4 keV of this is contained within the illuminated volume (indicated by the shading).

A further gain in durability is expected for even smaller beams. One can still expect some further reductions in the scattering power necessary for data collection in experiments with micrometre- or submicrometre-sized beams applied to protein microcrystals (Fig. 6 ▶). Electron escape from the illuminated volume could explain the remarkable stability of xylanase during data collection and also the discrepancy with previously predicted smallest crystal volumes for diffraction (Fig. 6 ▶). The presence of electron escape introduces the influence of neighbouring diffracting volumes of consequent images to each other. However, the assumption of a fresh crystal volume for the next diffraction image roughly remains true because only a small fraction of electrons will escape in the next illuminated volume, with the majority of electrons escaping out of the crystal slice selected by the beam during data collection. Our current study anticipates that protein crystals with volumes as small as 20 µm3 could be used for structure solution. This indicates that random data collection on micrometre-size crystals presents a real opportunity. Data-collection strategies with random crystal orientation are successfully used in electron crystallography of two-dimensional crystals and in the crystallography of viruses. We propose a similar strategy. Data from multiple microcrystals with random orientations could be collected using a microbeam and complete data sets merged from all of these. However, an improved microdiffraction setup and dedicated software need to be developed. For scanning crystallography to be successful, we have to assume that the crystal powder contains at least a large fraction of well diffracting but very small crystals that are isomorphous. High mosaicity will reduce the signal-to-noise ratio and lead to lower resolution. At present, we propose a scanning method that will use at least half a degree rotation per frame in order to reduce the problem with partial recorded reflections. A consequence of partial reflections is that we will need to record many more frames than in a conventional single-crystal experiment to reach an acceptable level of completeness. It is also very likely that the present indexing and scaling procedures will need to be further improved to process randomly collected data efficiently. Pixel detectors with small pixel size and reduced point-spread function will provide fast and sensitive readout of diffraction data, which will be necessary for successful scanning and random data-collection strategies. Furthermore, more detailed experimental studies on limiting factors to microcrystal diffraction making use of instrumental and X-ray optical advances are required. To this end, an advanced microgoniometer is currently under construction at the ID13 beamline nanofocus extension. With this setup, we will be able to verify if very small beams will significantly reduce the radiation-damage problem. PDB reference: xylanase II, 2jic, r2jicsf
  34 in total

1.  Characterization of conditions required for X-Ray diffraction experiments with protein microcrystals.

Authors:  R Glaeser; M Facciotti; P Walian; S Rouhani; J Holton; A MacDowell; R Celestre; D Cambie; H Padmore
Journal:  Biophys J       Date:  2000-06       Impact factor: 4.033

2.  A comparison of enzyme-aided bleaching of softwood paper pulp using combinations of xylanase, mannanase and alpha-galactosidase.

Authors:  J H Clarke; K Davidson; J E Rixon; J R Halstead; M P Fransen; H J Gilbert; G P Hazlewood
Journal:  Appl Microbiol Biotechnol       Date:  2000-06       Impact factor: 4.813

3.  Structural changes in a cryo-cooled protein crystal owing to radiation damage.

Authors:  W P Burmeister
Journal:  Acta Crystallogr D Biol Crystallogr       Date:  2000-03

4.  Specific chemical and structural damage to proteins produced by synchrotron radiation.

Authors:  M Weik; R B Ravelli; G Kryger; S McSweeney; M L Raves; M Harel; P Gros; I Silman; J Kroon; J L Sussman
Journal:  Proc Natl Acad Sci U S A       Date:  2000-01-18       Impact factor: 11.205

5.  Crystallography & NMR system: A new software suite for macromolecular structure determination.

Authors:  A T Brünger; P D Adams; G M Clore; W L DeLano; P Gros; R W Grosse-Kunstleve; J S Jiang; J Kuszewski; M Nilges; N S Pannu; R J Read; L M Rice; T Simonson; G L Warren
Journal:  Acta Crystallogr D Biol Crystallogr       Date:  1998-09-01

Review 6.  Small is beautiful: protein micro-crystallography.

Authors:  S Cusack; H Belrhali; A Bram; M Burghammer; A Perrakis; C Riekel
Journal:  Nat Struct Biol       Date:  1998-08

7.  Primary radiation damage of protein crystals by an intense synchrotron X-ray beam.

Authors:  T Y Teng; K Moffat
Journal:  J Synchrotron Radiat       Date:  2000-09-01       Impact factor: 2.616

8.  Crystals of family 11 xylanase II from Trichoderma longibrachiatum that diffract to atomic resolution.

Authors:  Natalia Moiseeva; Marc Allaire
Journal:  Acta Crystallogr D Biol Crystallogr       Date:  2004-06-22

9.  Structure of the integrin alpha2beta1-binding collagen peptide.

Authors:  Jonas Emsley; C Graham Knight; Richard W Farndale; Michael J Barnes
Journal:  J Mol Biol       Date:  2004-01-23       Impact factor: 5.469

10.  Will reduced radiation damage occur with very small crystals?

Authors:  Colin Nave; Mark A Hill
Journal:  J Synchrotron Radiat       Date:  2005-04-14       Impact factor: 2.616

View more
  39 in total

1.  Biocrystallography: past, present, future.

Authors:  Richard Giegé; Claude Sauter
Journal:  HFSP J       Date:  2010-04-22

2.  Multi-crystal anomalous diffraction for low-resolution macromolecular phasing.

Authors:  Qun Liu; Zhen Zhang; Wayne A Hendrickson
Journal:  Acta Crystallogr D Biol Crystallogr       Date:  2010-12-16

3.  Mini-beam collimator enables microcrystallography experiments on standard beamlines.

Authors:  Robert F Fischetti; Shenglan Xu; Derek W Yoder; Michael Becker; Venugopalan Nagarajan; Ruslan Sanishvili; Mark C Hilgart; Sergey Stepanov; Oleg Makarov; Janet L Smith
Journal:  J Synchrotron Radiat       Date:  2009-01-10       Impact factor: 2.616

4.  Phasing statistics for alpha helical membrane protein structures.

Authors:  Joanne L Parker; Simon Newstead
Journal:  Protein Sci       Date:  2013-09-17       Impact factor: 6.725

5.  Feasibility of one-shot-per-crystal structure determination using Laue diffraction.

Authors:  Sterling Cornaby; Doletha M E Szebenyi; Detlef-M Smilgies; David J Schuller; Richard Gillilan; Quan Hao; Donald H Bilderback
Journal:  Acta Crystallogr D Biol Crystallogr       Date:  2009-12-21

Review 6.  Rastering strategy for screening and centring of microcrystal samples of human membrane proteins with a sub-10 microm size X-ray synchrotron beam.

Authors:  Vadim Cherezov; Michael A Hanson; Mark T Griffith; Mark C Hilgart; Ruslan Sanishvili; Venugopalan Nagarajan; Sergey Stepanov; Robert F Fischetti; Peter Kuhn; Raymond C Stevens
Journal:  J R Soc Interface       Date:  2009-06-17       Impact factor: 4.118

7.  Microcrystallography using single-bounce monocapillary optics.

Authors:  R E Gillilan; M J Cook; S W Cornaby; D H Bilderback
Journal:  J Synchrotron Radiat       Date:  2010-01-19       Impact factor: 2.616

8.  Fast fluorescence techniques for crystallography beamlines.

Authors:  Sergey Stepanov; Mark Hilgart; Derek W Yoder; Oleg Makarov; Michael Becker; Ruslan Sanishvili; Craig M Ogata; Nagarajan Venugopalan; David Aragão; Martin Caffrey; Janet L Smith; Robert F Fischetti
Journal:  J Appl Crystallogr       Date:  2011-06-08       Impact factor: 3.304

9.  Optimization of data collection taking radiation damage into account.

Authors:  Gleb P Bourenkov; Alexander N Popov