Literature DB >> 18214413

[A-mode ultrasonic pointer for navigated pelvic surgery].

M Oszwald1, M Citak, J Kowal, C Amstutz, D Kendoff, T Kirchhoff, L P Nolte, C Krettek, T Hüfner.   

Abstract

Surgical navigation has proven to be a minimally invasive procedure that enables precise surgical interventions with reduced exposure to irradiation for patient and personnel. Fluoroscopy-based modules have prevailed on the market. For certain operations of the pelvis computed tomography is necessary with its high imaging quality and considerably larger scan volume. To enable navigation in these cases, matching of the CT data set and the patient's real pelvic bone is essential. The common pair point-matching algorithm is complemented by the surface-matching algorithm to achieve an even higher overall precision of the system. For conventional surface matching with a solid pointer, the bone has to be exposed from soft tissue quite extensively, using a solid pointer. This conflicts with the claim of computer-assisted surgery to be minimally invasive. We integrated an A-mode ultrasonic pointer with the intention to perform extended surface matching on the pelvic bone noninvasively. Related to the conventional method, comparable and to some extent even improved precision conditions could be established.

Entities:  

Mesh:

Year:  2008        PMID: 18214413     DOI: 10.1007/s00113-007-1382-8

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  19 in total

1.  Computer-assisted spine surgery.

Authors:  P Merloz; J Tonetti; L Pittet; M Coulomb; S Lavallée; J Troccaz; P Cinquin; P Sautot
Journal:  Comput Aided Surg       Date:  1998

2.  Iliosacral screw insertion using computer-assisted CT image guidance: a laboratory study.

Authors:  E F Barrick; J W O'Mara; H E Lane
Journal:  Comput Aided Surg       Date:  1998

3.  Accuracy evaluation of surface-based registration methods in a computer navigation system for hip surgery performed through a posterolateral approach.

Authors:  N Sugano; T Sasama; Y Sato; Y Nakajima; T Nishii; K Yonenobu; S Tamura; T Ochi
Journal:  Comput Aided Surg       Date:  2001

4.  [Ultrasound hard tissue detection for registration in orthopedics and traumatology].

Authors:  S H Tretbar; E C Weiss; M Hoss; S Schreiner; P Keppler; W Blömer; R M Lemor
Journal:  Biomed Tech (Berl)       Date:  2002       Impact factor: 1.411

5.  [Visual user guidance for registration based on A-mode ultrasound].

Authors:  S Heger; F Portheine; J Ohnsorge; K Radermacher
Journal:  Biomed Tech (Berl)       Date:  2002       Impact factor: 1.411

6.  Percutaneous screw fixation of acetabular fractures with CT guidance: preliminary results of a new technique.

Authors:  S B Gay; C Sistrom; G J Wang; D A Kahler; T Boman; N McHugh; H T Goitz
Journal:  AJR Am J Roentgenol       Date:  1992-04       Impact factor: 3.959

7.  Percutaneous iliosacral screw placement using image guided techniques.

Authors:  J Tonetti; L Carrat; S Lavalleé; L Pittet; P Merloz; J P Chirossel
Journal:  Clin Orthop Relat Res       Date:  1998-09       Impact factor: 4.176

8.  Proximity of iliosacral screws to neurovascular structures after internal fixation.

Authors:  D Templeman; A Schmidt; J Freese; I Weisman
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

9.  Iliosacral screw fixation: early complications of the percutaneous technique.

Authors:  M L Routt; P T Simonian; W J Mills
Journal:  J Orthop Trauma       Date:  1997-11       Impact factor: 2.512

10.  A-mode ultrasound-based registration in computer-aided surgery of the skull.

Authors:  Christoph Amstutz; Marco Caversaccio; Jens Kowal; Richard Bächler; Lutz-Peter Nolte; Rudolf Häusler; Martin Styner
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2003-12
View more
  2 in total

1.  [Automatic registration of patients with A-mode ultrasound for computer-assisted surgery. Laboratory proof of concept].

Authors:  G Diakov; F Kral; O Güler; W Freysinger
Journal:  HNO       Date:  2010-11       Impact factor: 1.284

2.  [Variability of the screw position after 3D-navigated sacroiliac screw fixation. Influence of the surgeon's experience with the navigation technique].

Authors:  G Konrad; J Zwingmann; E Kotter; N Südkamp; M Oberst
Journal:  Unfallchirurg       Date:  2010-01       Impact factor: 1.000

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.