Effect of multiple freeze-thaw cycles on intervertebral dynamic motion characteristics in the porcine lumbar spine.

Michio Hongo1, Ralph E Gay, Jui-Ting Hsu, Kristin D Zhao, Brice Ilharreborde, Lawrence J Berglund, Kai-Nan An.   

Abstract

Fresh frozen spine specimens are commonly used in biomechanical investigations of the spine. Since many study designs require staged preparation and testing, the effect of multiple freeze-thaw cycles on motion behavior should be understood. The objective of this study was to investigate the effect of multiple freeze-thaw cycles on the biomechanical parameters measured during dynamic pure moment loading. Ten porcine lumbar motion segments were harvested immediately after death and potted in acrylic fixtures. Specimens were tested in continuous pure moment flexion-extension, lateral flexion, and rotation cycles up to a limit of +/-5Nm. Moment-angular displacement data were analyzed and parameters quantified including range of motion, elastic zone, transitional zone (neutral region) size and slope, and width of the hysteresis loop. All specimens were tested at baseline and after each of three subsequent cycles of freezing and thawing. The transitional zone size decreased and the transitional zone slope increased during flexion-extension and lateral bending after the initial freeze-thaw cycle. These parameters were not altered after subsequent cycles. No significant change was observed in the elastic zone or width of hysteresis loop. Although freezing porcine spine specimens increased the stiffness in the neutral region of motion, up to three subsequent cycles of freezing and thawing did not further affect these motion characteristics. This suggests that data obtained from porcine spines which have been frozen and thawed multiple times are stable after initial freezing.

Mesh:

Year:  2008        PMID: 18078942      PMCID: PMC2278038          DOI: 10.1016/j.jbiomech.2007.11.003

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  26 in total

1.  Quantifying skeletal muscle properties in cadaveric test specimens: effects of mechanical loading, postmortem time, and freezer storage.

Authors:  C A Van Ee; A L Chasse; B S Myers
Journal:  J Biomech Eng       Date:  2000-02       Impact factor: 2.097

2.  Effect of frozen storage on the creep behavior of human intervertebral discs.

Authors:  N Dhillon; E C Bass; J C Lotz
Journal:  Spine (Phila Pa 1976)       Date:  2001-04-15       Impact factor: 3.468

3.  The effect of sagittal alignment on adjacent joint mobility after lumbar instrumentation--a biomechanical study of lumbar vertebrae in a porcine model.

Authors:  Wen-Jer Chen; Po-Liang Lai; Ching-Lung Tai; Lih-Huei Chen; Chi-Chien Niu
Journal:  Clin Biomech (Bristol, Avon)       Date:  2004-10       Impact factor: 2.063

4.  Stiffness and laxity of the knee--the contributions of the supporting structures. A quantitative in vitro study.

Authors:  K L Markolf; J S Mensch; H C Amstutz
Journal:  J Bone Joint Surg Am       Date:  1976-07       Impact factor: 5.284

5.  Effects of postmortem storage by freezing on ligament tensile behavior.

Authors:  S L Woo; C A Orlando; J F Camp; W H Akeson
Journal:  J Biomech       Date:  1986       Impact factor: 2.712

6.  A rheologic model for cortical bone. A study of the physical properties of human femoral samples.

Authors:  E D Sedlin
Journal:  Acta Orthop Scand Suppl       Date:  1965

7.  Biomechanical time-tolerance of fresh cadaveric human spine specimens.

Authors:  M M Panjabi; M Krag; D Summers; T Videman
Journal:  J Orthop Res       Date:  1985       Impact factor: 3.494

8.  The load on lumbar disks in different positions of the body.

Authors:  A Nachemson
Journal:  Clin Orthop Relat Res       Date:  1966 Mar-Apr       Impact factor: 4.176

9.  Laboratory conditions for tensile tests in annulus fibrosus from human intervertebral discs.

Authors:  C Hirsch; J Galante
Journal:  Acta Orthop Scand       Date:  1967

10.  The effect of hydration on the stiffness of intervertebral discs in an ovine model.

Authors:  John J Costi; Trevor C Hearn; Nicola L Fazzalari
Journal:  Clin Biomech (Bristol, Avon)       Date:  2002-07       Impact factor: 2.063

View more
  13 in total

1.  Repeated freeze-thawing of bone tissue affects Raman bone quality measurements.

Authors:  John-David P McElderry; Matthew R Kole; Michael D Morris
Journal:  J Biomed Opt       Date:  2011-07       Impact factor: 3.170

2.  Analysis of the impact of the course of hydration on the mechanical properties of the annulus fibrosus of the intervertebral disc.

Authors:  Małgorzata Żak; Celina Pezowicz
Journal:  Eur Spine J       Date:  2016-07-13       Impact factor: 3.134

3.  The shear modulus of the nucleus pulposus measured using magnetic resonance elastography: a potential biomarker for intervertebral disc degeneration.

Authors:  Daniel H Cortes; Jeremy F Magland; Alexander C Wright; Dawn M Elliott
Journal:  Magn Reson Med       Date:  2013-07-31       Impact factor: 4.668

4.  The role of patient-mode high-resolution peripheral quantitative computed tomography indices in the prediction of failure strength of the elderly women's thoracic vertebral body.

Authors:  Y Lu; M Krause; N Bishop; K Sellenschloh; C-C Glüer; K Püschel; M Amling; M M Morlock; G Huber
Journal:  Osteoporos Int       Date:  2014-08-19       Impact factor: 4.507

5.  Elastic, permeability and swelling properties of human intervertebral disc tissues: A benchmark for tissue engineering.

Authors:  Daniel H Cortes; Nathan T Jacobs; John F DeLucca; Dawn M Elliott
Journal:  J Biomech       Date:  2013-12-25       Impact factor: 2.712

6.  Biomechanical evaluation of a biomimetic spinal construct.

Authors:  Tian Wang; Jonathon R Ball; Mattew H Pelletier; William R Walsh
Journal:  J Exp Orthop       Date:  2014-06-26

7.  Fabrication and properties of acellular porcine anulus fibrosus for tissue engineering in spine surgery.

Authors:  Lien-Chen Wu; Chang-Jung Chiang; Zen-Hao Liu; Yang-Hwei Tsuang; Jui-Sheng Sun; Yi-You Huang
Journal:  J Orthop Surg Res       Date:  2014-12-03       Impact factor: 2.359

8.  Verification of pure moment testing in a multi-degree of freedom spine testing apparatus.

Authors:  Amy M Fuller; Jennifer M Chui; Daniel J Cook; Matthew S Yeager; David A Gladowski; Boyle C Cheng
Journal:  Int J Spine Surg       Date:  2012-12-01

9.  Reduction of intradiscal pressure by the use of polycarbonate-urethane rods as compared to titanium rods in posterior thoracolumbar spinal fixation.

Authors:  Eva Jacobs; Alex K Roth; Jacobus J Arts; Lodewijk W van Rhijn; Paul C Willems
Journal:  J Mater Sci Mater Med       Date:  2017-08-21       Impact factor: 3.896

10.  Experimental Model of Proximal Junctional Fracture after Multilevel Posterior Spinal Instrumentation.

Authors:  Jean-Marc Mac-Thiong; Annie Levasseur; Stefan Parent; Yvan Petit
Journal:  Biomed Res Int       Date:  2016-08-17       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.