Literature DB >> 12135546

The effect of hydration on the stiffness of intervertebral discs in an ovine model.

John J Costi1, Trevor C Hearn, Nicola L Fazzalari.   

Abstract

OBJECTIVE: To determine the hydration-over-time behaviour of ovine intervertebral discs and intact joints in a saline bath at body temperature and the effect this has on their stiffness compared to air at ambient temperature.
DESIGN: The hydration-over-time behaviour and stiffness of the ovine functional spinal unit and disc were quantified.
BACKGROUND: The fluid content of an intervertebral disc is not constant but varies with external load and load history. The stiffness of ovine functional spinal units in a hydrated environment and how this compares to testing in air have not been quantified.
METHODS: Intervertebral discs and functional spinal units were weighed and soaked in a saline water bath at 37 degrees C and reweighed each hour for 6 h. They were then allowed to stand in air at room temperature while the time to return to initial weight was recorded. Functional spinal units were randomly assigned to two groups. Axial compression, flexion, extension, lateral bending and axial torsion tests were performed on both the intact functional spinal unit and isolated disc. Group 1 was tested in air then in a saline water bath at 37 degrees C with the testing order reversed for Group 2.
RESULTS: Hydration of the disc reached a plateau after an average 3-4 h of soaking with the largest increase seen in the first hour. Four hours, standing in air at room temperature, was required to return specimens to their initial weight. The functional spinal unit stiffness was significantly lower for those specimens tested in the bath compared to air.
CONCLUSIONS: Ovine intervertebral discs show similar hydration-over-time behaviour when compared to human discs. Stiffnesses in different modes of loading were significantly different when tested in a hydrated environment compared with the standard method of testing in air. RELEVANCE: It has been shown that there are biomechanical and biochemical similarities between sheep and human intervertebral discs. Despite these similarities, no studies have looked at how ovine intervertebral discs behave over time in a hydrated environment. In humans, hydration levels are an important aspect of intervertebral disc degeneration. There is also a relationship between decreased hydration levels and increased stiffness. This study demonstrates the similarities between human and ovine hydration-over-time behaviour. The importance of intervertebral disc hydration and its effects on stiffness under different modes of loading were also demonstrated and have not been previously shown using the ovine model. In this context, the results from this study provide further support for the use of the ovine model.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12135546     DOI: 10.1016/s0268-0033(02)00035-9

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  19 in total

1.  Advanced Multi-Axis Spine Testing: Clinical Relevance and Research Recommendations.

Authors:  Timothy P Holsgrove; Nikhil R Nayak; William C Welch; Beth A Winkelstein
Journal:  Int J Spine Surg       Date:  2015-07-17

2.  Effect of multiple freeze-thaw cycles on intervertebral dynamic motion characteristics in the porcine lumbar spine.

Authors:  Michio Hongo; Ralph E Gay; Jui-Ting Hsu; Kristin D Zhao; Brice Ilharreborde; Lawrence J Berglund; Kai-Nan An
Journal:  J Biomech       Date:  2008-02-20       Impact factor: 2.712

3.  Influence of asymmetric tether on the macroscopic permeability of the vertebral end plate.

Authors:  Jean Michel Laffosse; Franck Accadbled; Thierry Odent; Thibault Cachon; Anne Gomez-Brouchet; Dominique Ambard; Eric Viguier; Jérôme Sales de Gauzy; Pascal Swider
Journal:  Eur Spine J       Date:  2009-08-20       Impact factor: 3.134

4.  Micro-computed tomography study of the subchondral bone of the vertebral endplates in a porcine model: correlations with histomorphometric parameters.

Authors:  Jean-Michel Laffosse; Charles Kinkpe; Anne Gomez-Brouchet; Franck Accadbled; Eric Viguier; Jérôme Sales de Gauzy; Pascal Swider
Journal:  Surg Radiol Anat       Date:  2009-10-08       Impact factor: 1.246

5.  The high-throughput phenotyping of the viscoelastic behavior of whole mouse intervertebral discs using a novel method of dynamic mechanical testing.

Authors:  Jennifer W Liu; Adam C Abraham; Simon Y Tang
Journal:  J Biomech       Date:  2015-05-06       Impact factor: 2.712

6.  Lumbar annulus fibrosus biomechanical characterization in healthy children by ultrasound shear wave elastography.

Authors:  Claudio Vergari; Guillaume Dubois; Raphael Vialle; Jean-Luc Gennisson; Mickael Tanter; Jean Dubousset; Philippe Rouch; Wafa Skalli
Journal:  Eur Radiol       Date:  2015-07-22       Impact factor: 5.315

Review 7.  Vertebral subchondral bone.

Authors:  C Nguyen; S Poiraudeau; F Rannou
Journal:  Osteoporos Int       Date:  2012-11-22       Impact factor: 4.507

8.  The aging disc: using an ovine model to examine age-related differences in the biomechanical properties of the intralamellar matrix of single lamellae.

Authors:  Danielle M Stewart; Lauren A Monaco; Diane E Gregory
Journal:  Eur Spine J       Date:  2016-05-10       Impact factor: 3.134

9.  Analysis of the impact of the course of hydration on the mechanical properties of the annulus fibrosus of the intervertebral disc.

Authors:  Małgorzata Żak; Celina Pezowicz
Journal:  Eur Spine J       Date:  2016-07-13       Impact factor: 3.134

10.  Frequency-dependent behavior of the intervertebral disc in response to each of six degree of freedom dynamic loading: solid phase and fluid phase contributions.

Authors:  John J Costi; Ian A Stokes; Mack G Gardner-Morse; James C Iatridis
Journal:  Spine (Phila Pa 1976)       Date:  2008-07-15       Impact factor: 3.468

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.