PURPOSE: This study aims to: (1) measure the shear modulus of nucleus pulposus (NP) in intact human vertebra-disc-vertebra segments using a magnetic resonance elastography setup for a 7T whole-body scanner, (2) quantify the effect of disc degeneration on the NP shear modulus measured using magnetic resonance elastography, and (3) compare the NP shear modulus to other magnetic resonance-based biomarkers of dis degeneration. METHODS: Thirty intact human disc segments were classified as normal, mild, or severely degenerated. The NP shear modulus was measured using a custom-made setup that included a novel inverse method less sensitive to noisy displacements. T2 relaxation time was measured at 7T. The accuracy of these parameters to classify different degrees of degeneration was evaluated using receiver operating characteristic curves. RESULTS: The magnetic resonance elastography measure of shear modulus in the NP was able to differentiate between normal, mild degeneration, and severe degeneration. The T2 relaxation time was able to differentiate between normal and mild degeneration, but it could not distinguish between mild and severe degeneration. CONCLUSIONS: This study shows that the NP shear modulus measured using magnetic resonance elastography is sensitive to disc degeneration and has the potential of being used as a clinical tool to quantify the mechanical integrity of the intervertebral disc.
PURPOSE: This study aims to: (1) measure the shear modulus of nucleus pulposus (NP) in intact humanvertebra-disc-vertebra segments using a magnetic resonance elastography setup for a 7T whole-body scanner, (2) quantify the effect of disc degeneration on the NP shear modulus measured using magnetic resonance elastography, and (3) compare the NP shear modulus to other magnetic resonance-based biomarkers of dis degeneration. METHODS: Thirty intact human disc segments were classified as normal, mild, or severely degenerated. The NP shear modulus was measured using a custom-made setup that included a novel inverse method less sensitive to noisy displacements. T2 relaxation time was measured at 7T. The accuracy of these parameters to classify different degrees of degeneration was evaluated using receiver operating characteristic curves. RESULTS: The magnetic resonance elastography measure of shear modulus in the NP was able to differentiate between normal, mild degeneration, and severe degeneration. The T2 relaxation time was able to differentiate between normal and mild degeneration, but it could not distinguish between mild and severe degeneration. CONCLUSIONS: This study shows that the NP shear modulus measured using magnetic resonance elastography is sensitive to disc degeneration and has the potential of being used as a clinical tool to quantify the mechanical integrity of the intervertebral disc.
Authors: Ehsan Jazini; Alok D Sharan; Lee Jae Morse; Jonathon P Dyke; Eric B Aronowitz; Louis K H Chen; Simon Y Tang Journal: Spine (Phila Pa 1976) Date: 2012-02-15 Impact factor: 3.468
Authors: Curtis L Johnson; Matthew D J McGarry; Elijah E W Van Houten; John B Weaver; Keith D Paulsen; Bradley P Sutton; John G Georgiadis Journal: Magn Reson Med Date: 2012-09-21 Impact factor: 4.668
Authors: John F DeLucca; Daniel H Cortes; Nathan T Jacobs; Edward J Vresilovic; Randall L Duncan; Dawn M Elliott Journal: J Biomech Date: 2016-01-14 Impact factor: 2.712
Authors: Benjamin A Walter; Prasath Mageswaran; Xiaokui Mo; Daniel J Boulter; Hazem Mashaly; Xuan V Nguyen; Luciano M Prevedello; William Thoman; Brian D Raterman; Prateek Kalra; Ehud Mendel; William S Marras; Arunark Kolipaka Journal: Radiology Date: 2017-05-04 Impact factor: 11.105
Authors: Kathryn T Weber; Timothy D Jacobsen; Robert Maidhof; Justin Virojanapa; Chris Overby; Ona Bloom; Shaheda Quraishi; Mitchell Levine; Nadeen O Chahine Journal: Curr Rev Musculoskelet Med Date: 2015-03
Authors: Daniel H Cortes; Stephen M Suydam; Karin Grävare Silbernagel; Thomas S Buchanan; Dawn M Elliott Journal: Ultrasound Med Biol Date: 2015-03-19 Impact factor: 2.998
Authors: Ephraim I Ben-Abraham; Jun Chen; Joel P Felmlee; Phil Rossman; Armando Manduca; Kai-Nan An; Richard L Ehman Journal: Magn Reson Imaging Date: 2015-12-30 Impact factor: 2.546