Literature DB >> 17992808

Calculating arterial pressure-based cardiac output using a novel measurement and analysis method.

Benjamin Pratt1, Luchy Roteliuk, Feras Hatib, John Frazier, Roy D Wallen.   

Abstract

Work on applying physical and physiological principles for determining cardiac output by analysis of pressure measurements has been pursued for decades. Reference measurements for this kind of cardiac output analysis rely on the pulmonary artery catheter (PAC), considered the clinical gold standard for cardiac output monitoring. Recent advances in signal processing, as well as applied information on the relationships that enable arterial pulse pressure to be used to determine stroke volume, have led to the development of a novel system that can continuously measure cardiac output from an arterial pressure waveform that does not require an external calibration reference method. There are significant challenges in applying statistical- and signal-processing practices to the analysis of complex physiological waveforms. This paper reviews the historical basis for measuring flow from the analysis of pressure in a vessel, establishes the physiological and mathematical basis for this new system and describes its performance under various physiological conditions.

Entities:  

Mesh:

Year:  2007        PMID: 17992808     DOI: 10.2345/0899-8205(2007)41[403:CAPCOU]2.0.CO;2

Source DB:  PubMed          Journal:  Biomed Instrum Technol        ISSN: 0899-8205


  18 in total

1.  Comparison of an advanced minimally invasive cardiac output monitoring with a continuous invasive cardiac output monitoring during lung transplantation.

Authors:  Roland Tomasi; Stephan Prueckner; Stephan Czerner; Renè Schramm; Gerhard Preissler; Bernhard Zwißler; Vera von Dossow-Hanfstingl
Journal:  J Clin Monit Comput       Date:  2015-07-30       Impact factor: 2.502

2.  Continuous cardiac output measurement by un-calibrated pulse wave analysis and pulmonary artery catheter in patients with septic shock.

Authors:  Michael T Ganter; Jamal A Alhashemi; Adel M Al-Shabasy; Ursina M Schmid; Peter Schott; Sanaa A Shalabi; Ahmed M Badri; Sonja Hartnack; Christoph K Hofer
Journal:  J Clin Monit Comput       Date:  2015-02-27       Impact factor: 2.502

Review 3.  Advanced hemodynamic monitoring: principles and practice in neurocritical care.

Authors:  Christos Lazaridis
Journal:  Neurocrit Care       Date:  2012-02       Impact factor: 3.210

4.  Stroke volume variation obtained with Vigileo/FloTrac™ system during bleeding and fluid overload in dogs.

Authors:  Hiroyuki Taguchi; Keisuke Ichinose; Hironari Tanimoto; Michiko Sugita; Masafumi Tashiro; Tatsuo Yamamoto
Journal:  J Anesth       Date:  2011-06-04       Impact factor: 2.078

5.  Reliability of a new 4th generation FloTrac algorithm to track cardiac output changes in patients receiving phenylephrine.

Authors:  Fuhai Ji; Jian Li; Neal Fleming; David Rose; Hong Liu
Journal:  J Clin Monit Comput       Date:  2014-09-30       Impact factor: 2.502

6.  Cross-comparisons of trending accuracies of continuous cardiac-output measurements: pulse contour analysis, bioreactance, and pulmonary-artery catheter.

Authors:  Bouchra Lamia; Hyung Kook Kim; Donald A Severyn; Michael R Pinsky
Journal:  J Clin Monit Comput       Date:  2017-02-10       Impact factor: 2.502

7.  Cardiac output measured by uncalibrated arterial pressure waveform analysis by recently released software version 3.02 versus thermodilution in septic shock.

Authors:  Cornelis Slagt; Marcel A de Leeuw; Jan Beute; Emmy Rijnsburger; Martijn Hoeksema; Jan W R Mulder; Ignacio Malagon; A B Johan Groeneveld
Journal:  J Clin Monit Comput       Date:  2012-11-15       Impact factor: 2.502

8.  Artificial Intelligence and Machine Learning in Anesthesiology.

Authors:  Christopher W Connor
Journal:  Anesthesiology       Date:  2019-12       Impact factor: 7.892

9.  Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients.

Authors:  Daniel De Backer; Gernot Marx; Andrew Tan; Christopher Junker; Marc Van Nuffelen; Lars Hüter; Willy Ching; Frédéric Michard; Jean-Louis Vincent
Journal:  Intensive Care Med       Date:  2010-12-10       Impact factor: 17.440

10.  Impact of bypass flow rate and catheter position in veno-venous extracorporeal membrane oxygenation on gas exchange in vivo.

Authors:  Konomi Togo; Yoshiaki Takewa; Nobumasa Katagiri; Yutaka Fujii; Satoru Kishimoto; Kazuma Date; Yuji Miyamoto; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2014-12-05       Impact factor: 1.731

View more