Impact of bypass flow rate and catheter position in veno-venous extracorporeal membrane oxygenation on gas exchange in vivo.

Konomi Togo1, Yoshiaki Takewa, Nobumasa Katagiri, Yutaka Fujii, Satoru Kishimoto, Kazuma Date, Yuji Miyamoto, Eisuke Tatsumi.   

Abstract

The clinical use of veno-venous extracorporeal membrane oxygenation (VVECMO) in adult patients with respiratory failure is rapidly increasing. However, recirculation of blood oxygenated by ECMO back into the circuit may occur in VVECMO, resulting in insufficient oxygenation. The cannula position and bypass flow rate are two major factors influencing recirculation, but the relationship and ideal configuration of these factors are not fully understood. In the present study, we attempted to clarify these parameters for effective gas exchange. VVECMO was performed in eight adult goats under general anesthesia. The position of the drainage cannula was fixed in the inferior vena cava (IVC), but the return cannula position was varied between the IVC, right atrium (RA), and superior vena cava (SVC). At each position, the recirculation rates calculated, and the adequacy of oxygen delivery by ECMO in supplying systemic oxygen demand was assessed by measuring the arterial oxygen saturation (SaO2) and pressure (PaO2). Although the recirculation rates increased as the bypass flow rates increased, SaO2 and PaO2 also increased in any position of return cannula. The recirculation rates and PaO2 were 27 ± 2% and 162 ± 16 mmHg, 36 ± 6% and 139 ± 11 mmHg, and 63 ± 6% and 77 ± 9 mmHg in the SVC, RA and IVC position at 4 L/min respectively. In conclusion, the best return cannula position was the SVC, and a high bypass flow rate was advantageous for effective oxygenation. Both the bypass flow rates and cannula position must be considered to achieve effective oxygenation.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25477271     DOI: 10.1007/s10047-014-0810-0

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  17 in total

1.  Recirculation in double lumen catheter veno-venous extracorporeal membrane oxygenation measured by an ultrasound dilution technique.

Authors:  A F van Heijst; F H van der Staak; A F de Haan; K D Liem; C Festen; W B Geven; M van de Bor
Journal:  ASAIO J       Date:  2001 Jul-Aug       Impact factor: 2.872

Review 2.  Contemporary extracorporeal membrane oxygenation for adult respiratory failure: life support in the new era.

Authors:  Graeme MacLaren; Alain Combes; Robert H Bartlett
Journal:  Intensive Care Med       Date:  2011-12-07       Impact factor: 17.440

3.  Up to 151 days of continuous animal perfusion with trivial heparin infusion by the application of a long-term durable antithrombogenic coating to a combination of a seal-less centrifugal pump and a diffusion membrane oxygenator.

Authors:  Tomohiro Nishinaka; Eisuke Tatsumi; Nobumasa Katagiri; Hiroyuki Ohnishi; Toshihide Mizuno; Kyoko Shioya; Tomonori Tsukiya; Akihiko Homma; Susumu Kashiwabara; Hidenori Tanaka; Masaki Sato; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2007-12-20       Impact factor: 1.731

4.  Use of bicaval dual-lumen catheter for adult venovenous extracorporeal membrane oxygenation.

Authors:  Jeffrey Javidfar; Daniel Brodie; Dongfang Wang; Ali N Ibrahimiye; Jonathan Yang; Joseph B Zwischenberger; Joshua Sonett; Matthew Bacchetta
Journal:  Ann Thorac Surg       Date:  2011-06       Impact factor: 4.330

5.  Extracorporeal life support: the University of Michigan experience.

Authors:  R H Bartlett; D W Roloff; J R Custer; J G Younger; R B Hirschl
Journal:  JAMA       Date:  2000-02-16       Impact factor: 56.272

6.  The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model.

Authors:  G J Langewouters; K H Wesseling; W J Goedhard
Journal:  J Biomech       Date:  1984       Impact factor: 2.712

7.  Extracorporeal membrane oxygenation using the TandemHeart System's catheters.

Authors:  James P Herlihy; Pranav Loyalka; Gnananandh Jayaraman; Biswajit Kar; Igor D Gregoric
Journal:  Tex Heart Inst J       Date:  2009

8.  Extracorporeal Life Support Organization Registry Report 2012.

Authors:  Matthew L Paden; Steven A Conrad; Peter T Rycus; Ravi R Thiagarajan
Journal:  ASAIO J       Date:  2013 May-Jun       Impact factor: 2.872

9.  Clinical experience of more than 2 months usage of extracorporeal membrane oxygenation (Endumo(®)4000) without circuit exchange.

Authors:  Kunio Kusajima; Takaya Hoashi; Koji Kagisaki; Kotaro Yoshida; Takayuki Nishigaki; Teruyuki Hayashi; Hajime Ichikawa
Journal:  J Artif Organs       Date:  2013-12-31       Impact factor: 1.731

10.  Quantification of recirculation as an adjuvant to transthoracic echocardiography for optimization of dual-lumen extracorporeal life support.

Authors:  Erik P J Körver; Yuri M Ganushchak; Antoine P Simons; Dirk W Donker; Jos G Maessen; Patrick W Weerwind
Journal:  Intensive Care Med       Date:  2012-03-29       Impact factor: 17.440

View more
  4 in total

Review 1.  Clinical significance of echocardiography in patients supported by venous-venous extracorporeal membrane oxygenation.

Authors:  Adriano Peris; Chiara Lazzeri; Giovanni Cianchi; Manuela Bonizzoli; Stefano Batacchi; Pasquale Bernardo; Serafina Valente; Gian Franco Gensini
Journal:  J Artif Organs       Date:  2015-02-24       Impact factor: 1.731

Review 2.  Journal of Artificial Organs 2015: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; K Matsuda; E Tatsumi; G Matsumiya; T Tsukiya; T Abe; K Fukunaga; A Kishida; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2016-02-20       Impact factor: 1.731

Review 3.  The Role of Echocardiography in Neonates and Pediatric Patients on Extracorporeal Membrane Oxygenation.

Authors:  Carles Bautista-Rodriguez; Joan Sanchez-de-Toledo; Eduardo M Da Cruz
Journal:  Front Pediatr       Date:  2018-10-26       Impact factor: 3.418

4.  Extracorporeal Membrane Oxygenation Blood Flow and Blood Recirculation Compromise Thermodilution-Based Measurements of Cardiac Output.

Authors:  Martin Russ; Elvira Steiner; Willehad Boemke; Thilo Busch; Christoph Melzer-Gartzke; Mahdi Taher; Jenelle Badulak; Steffen Weber-Carstens; Erik R Swenson; Roland C E Francis; Philipp A Pickerodt
Journal:  ASAIO J       Date:  2021-11-27       Impact factor: 3.826

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.