Literature DB >> 17992473

Pre-clinical studies to validate the MITCH PCR Cup: a flexible and anatomically shaped acetabular component with novel bearing characteristics.

Ahmed M H Latif1, Aude Mehats, Martyn Elcocks, Neil Rushton, Richard E Field, Eric Jones.   

Abstract

A previous clinical study was undertaken to evaluate the safety and efficacy of an anatomically shaped, flexible acetabular cup. Clinical results achieved were satisfactory, although some deficiencies in the model were identified. Design changes to the original model have been implemented to improve both initial stability and long term biological fixation. This was achieved through modifications made to both the anchoring mechanism and by the application of an appropriate backing surface layer promoting bone on-growth. In addition, changes to the articulation couple have also been introduced to improve implant durability and bearing performance, utilising a carbon fibre reinforced polyetheretherketone--alumina couple. Simulated loading, in both models, was performed using Finite Element Analysis. Mechanical and tribological tests were also performed to ensure the robustness of the new optimised design. Bio-compatibility of the articulation couple was demonstrated using an animal model. Implantation of the device has been extensively tested and re-validated in vitro to achieve a favourable polar contact between cup and femoral head and establish a reproducible operative technique. This preliminary work is undertaken prior to commencing a post market surveillance study of the CE marked implant.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17992473     DOI: 10.1007/s10856-007-3256-6

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  13 in total

1.  A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award.

Authors:  O K Muratoglu; C R Bragdon; D O O'Connor; M Jasty; W H Harris
Journal:  J Arthroplasty       Date:  2001-02       Impact factor: 4.757

2.  Bone remodeling around the Cambridge cup: a DEXA study of 50 hips over 2 years.

Authors:  Richard E Field; Michael D Cronin; Parminder J Singh; Christine Burtenshaw; Neil Rushton
Journal:  Acta Orthop       Date:  2006-10       Impact factor: 3.717

3.  Pelvic muscle and acetabular contact forces during gait.

Authors:  D R Pedersen; R A Brand; D T Davy
Journal:  J Biomech       Date:  1997-09       Impact factor: 2.712

4.  Frictional properties of artificial hip joints.

Authors:  A Unsworth; M J Pearcy; E F White; G White
Journal:  Eng Med       Date:  1988-07

5.  Mechanical and textural properties of pelvic trabecular bone.

Authors:  M Dalstra; R Huiskes; A Odgaard; L van Erning
Journal:  J Biomech       Date:  1993 Apr-May       Impact factor: 2.712

6.  Development and validation of a three-dimensional finite element model of the pelvic bone.

Authors:  M Dalstra; R Huiskes; L van Erning
Journal:  J Biomech Eng       Date:  1995-08       Impact factor: 2.097

7.  Mechanical analysis of the human pelvis and its application to the artificial hip joint--by means of the three dimensional finite element method.

Authors:  H Oonishi; H Isha; T Hasegawa
Journal:  J Biomech       Date:  1983       Impact factor: 2.712

8.  Cementless prosthesis of the hip joint with "spongy metal" surface. A prospective study.

Authors:  W Plötz; R Gradinger; H Rechl; R Ascherl; S Wicke-Wittenius; E Hipp
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

9.  Rationale of a flexible press fit cup in total hip replacement. 5-year followup in 280 procedures.

Authors:  E Morscher; B Berli; W Jockers; R Schenk
Journal:  Clin Orthop Relat Res       Date:  1997-08       Impact factor: 4.176

10.  Grit-blasted titanium femoral stem in cementless primary total hip arthroplasty: a 5- to 10-year multicenter study.

Authors:  C Delaunay; F Bonnomet; J North; D Jobard; C Cazeau; J F Kempf
Journal:  J Arthroplasty       Date:  2001-01       Impact factor: 4.757

View more
  6 in total

1.  Elevated cytokine expression of different PEEK wear particles compared to UHMWPE in vivo.

Authors:  V Lorber; A C Paulus; A Buschmann; B Schmitt; T M Grupp; V Jansson; Sandra Utzschneider
Journal:  J Mater Sci Mater Med       Date:  2013-09-26       Impact factor: 3.896

Review 2.  New alternate bearing surfaces in total hip arthroplasty: A review of the current literature.

Authors:  Preston W Grieco; Scott Pascal; Jared M Newman; Neil V Shah; Sarah G Stroud; Neil P Sheth; Aditya V Maheshwari
Journal:  J Clin Orthop Trauma       Date:  2017-10-27

Review 3.  The Use of Carbon-Fiber-Reinforced (CFR) PEEK Material in Orthopedic Implants: A Systematic Review.

Authors:  Chuan Silvia Li; Christopher Vannabouathong; Sheila Sprague; Mohit Bhandari
Journal:  Clin Med Insights Arthritis Musculoskelet Disord       Date:  2015-02-23

Review 4.  The Biologic Response to Polyetheretherketone (PEEK) Wear Particles in Total Joint Replacement: A Systematic Review.

Authors:  Ashley A Stratton-Powell; Kinga M Pasko; Claire L Brockett; Joanne L Tipper
Journal:  Clin Orthop Relat Res       Date:  2016-07-18       Impact factor: 4.176

5.  Histopathological Analysis of PEEK Wear Particle Effects on the Synovial Tissue of Patients.

Authors:  A C Paulus; S Haßelt; V Jansson; A Giurea; H Neuhaus; T M Grupp; S Utzschneider
Journal:  Biomed Res Int       Date:  2016-08-16       Impact factor: 3.411

6.  Rapid Analyses of Polyetheretherketone Wear Characteristics by Accelerated Wear Testing with Microfabricated Surfaces for Artificial Joint Systems.

Authors:  Chen-Ying Su; Chien-Wei Kuo; Hsu-Wei Fang
Journal:  Biomed Res Int       Date:  2017-11-02       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.