Literature DB >> 9302620

Pelvic muscle and acetabular contact forces during gait.

D R Pedersen1, R A Brand, D T Davy.   

Abstract

Locations, magnitudes, and directions of pelvic muscle and acetabular contact forces are important to model the effects of abnormal conditions (e.g., deformity, surgery) of the hip accurately. Such data have not been reported previously. We computed the three-dimensional locations of all pelvic muscle and acetabular contact forces during level gait. The approach first required computation of the intersegmental joint resultant forces and moments using limb displacement history, foot-floor forces, and estimated limb inertial properties from one subject. The intersegmental resultant moments were then distributed to the muscles using a 47-element muscle model and a non-linear optimization scheme. Muscle forces were vectorally subtracted from the intersegmental resultants to compute the acetabular contact forces. While the peak joint force magnitudes are similar to those reported previously for the femur, the directions of pelvic contact forces and muscle forces varied considerably over the gait cycle. These variations in contact force directions and three-dimensional forces could be as important as the contact force magnitudes in performing experimental or theoretical studies of loads and stresses in the periacetabular region.

Entities:  

Mesh:

Year:  1997        PMID: 9302620     DOI: 10.1016/s0021-9290(97)00041-9

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  25 in total

1.  Hip stress reduction after Chiari osteotomy.

Authors:  S Herman; A Jaklic; S Herman; A Iglic; V Kralj-Iglic
Journal:  Med Biol Eng Comput       Date:  2002-07       Impact factor: 2.602

2.  Pre-clinical studies to validate the MITCH PCR Cup: a flexible and anatomically shaped acetabular component with novel bearing characteristics.

Authors:  Ahmed M H Latif; Aude Mehats; Martyn Elcocks; Neil Rushton; Richard E Field; Eric Jones
Journal:  J Mater Sci Mater Med       Date:  2007-11-08       Impact factor: 3.896

3.  Postoperative acetabular retroversion causes posterior osteoarthritis of the hip.

Authors:  Takahiko Kiyama; Masatoshi Naito; Kei Shiramizu; Tsuyoshi Shinoda
Journal:  Int Orthop       Date:  2007-12-21       Impact factor: 3.075

4.  Evaluation of acetabular versions after a curved periacetabular osteotomy for dysplastic hips.

Authors:  Jun Xie; Masatoshi Naito; Akira Maeyama
Journal:  Int Orthop       Date:  2009-05-08       Impact factor: 3.075

5.  Normal and osteoarthritic hip joint mechanical behaviour: a comparison study.

Authors:  A Pustoc'h; L Cheze
Journal:  Med Biol Eng Comput       Date:  2009-02-13       Impact factor: 2.602

6.  Role of optimization criterion in static asymmetric analysis of lumbar spine load.

Authors:  Matej Daniel
Journal:  Wien Med Wochenschr       Date:  2011-07-29

7.  A novel combined hemipelvic endoprosthesis for peri-acetabular tumours involving sacroiliac joint: a finite element study.

Authors:  Bo Wang; Peidong Sun; Xianbiao Xie; Weidong Wu; Jian Tu; Jun Ouyang; Jingnan Shen
Journal:  Int Orthop       Date:  2015-07-17       Impact factor: 3.075

8.  Finite element analysis of the pelvis after modular hemipelvic endoprosthesis reconstruction.

Authors:  Yong Zhou; Li Min; Yang Liu; Rui Shi; Wenli Zhang; Hui Zhang; Hong Duan; Chongqi Tu
Journal:  Int Orthop       Date:  2013-01-15       Impact factor: 3.075

9.  Polyethylene wear is related to patient-specific contact stress in THA.

Authors:  Robert Košak; Veronika Kralj-Iglič; Aleš Iglič; Matej Daniel
Journal:  Clin Orthop Relat Res       Date:  2011-09-24       Impact factor: 4.176

10.  A biomechanical assessment of modular and monoblock revision hip implants using FE analysis and strain gage measurements.

Authors:  Habiba Bougherara; Rad Zdero; Suraj Shah; Milan Miric; Marcello Papini; Paul Zalzal; Emil H Schemitsch
Journal:  J Orthop Surg Res       Date:  2010-05-12       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.