Literature DB >> 11172270

Grit-blasted titanium femoral stem in cementless primary total hip arthroplasty: a 5- to 10-year multicenter study.

C Delaunay1, F Bonnomet, J North, D Jobard, C Cazeau, J F Kempf.   

Abstract

A total of 133 cementless primary total hip arthroplasties using the Zweymuller-Alloclassic grit-blasted titanium tapered stem were performed in 3 institutions. The patient cohort was divided into 2 subgroups, nonselected and selected, on the basis of excellent bone stock and age (<65 years old at surgery). Acetabular components were all cementless, and bearing surfaces were all alumina-ceramic on polyethylene. After a 7.3-year average follow-up period (range, 5-10 years), 118 primary femoral replacements in 109 patients could be reviewed fully. Mean age at surgery was 55.7 years (range, 27-84 years). According to the Merle d'Aubigne and Charnley rating system, clinical results were graded excellent and good in 89% of hips and fair in 11%. Radiologically, early subsidence >2 mm could be detected in 4 hips (3.4%). Calcar atrophy and spot welds were noted in 77% and 82% of hips. Femoral osteolysis granuloma was noted in 4 hips (3.4%). There has been no stem fracture and no ceramic head breakage. The survivorship at 10 years with definite femoral aseptic loosening (radiographic failure) as the endpoint was 100% (95% Wilson confidence interval, 78.4%-100%; worst scenario, 95.4%). A significant difference between the nonselected and selected patient subgroups was observed only for early reoperation (P =.03) and proximal stress shielding (P =.01). Press-fitting but not filling the femoral canal with a rough titanium, straight, tapered femoral component represents, at intermediate follow-up, a promising cementless option in primary total hip arthroplasty.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11172270     DOI: 10.1054/arth.2001.17940

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  [Surface characterization of Al2O3-blasted titanium implants in total hip arthroplasty].

Authors:  A Schuh; U Holzwarth; W Kachler; J Göske; G Zeiler
Journal:  Orthopade       Date:  2004-08       Impact factor: 1.087

2.  Pre-clinical studies to validate the MITCH PCR Cup: a flexible and anatomically shaped acetabular component with novel bearing characteristics.

Authors:  Ahmed M H Latif; Aude Mehats; Martyn Elcocks; Neil Rushton; Richard E Field; Eric Jones
Journal:  J Mater Sci Mater Med       Date:  2007-11-08       Impact factor: 3.896

3.  Enhanced cell integration to titanium alloy by surface treatment with microarc oxidation: a pilot study.

Authors:  Young Wook Lim; Soon Yong Kwon; Doo Hoon Sun; Hyoun Ee Kim; Yong Sik Kim
Journal:  Clin Orthop Relat Res       Date:  2009-05-12       Impact factor: 4.176

4.  High incidence of stem loosening in association with periprosthetic femur fractures in previously well-fixed cementless grit-blasted tapered-wedge stems.

Authors:  Seung-Jae Lim; Kyung-Jae Lee; Byung-Woo Min; Joo-Hyoun Song; Sang-Yeon So; Youn-Soo Park
Journal:  Int Orthop       Date:  2014-11-11       Impact factor: 3.075

5.  Total hip arthroplasty with rectangular stems and subtrochanteric transverse shortening osteotomy in Crowe type IV hips: a retrospective study.

Authors:  Yusuf Erdem; Dogan Bek; Zafer Atbasi; Cagri Neyisci; Cemil Yildiz; Mustafa Basbozkurt
Journal:  Arthroplast Today       Date:  2019-05-10

6.  Biological Safety Evaluation and Surface Modification of Biocompatible Ti-15Zr-4Nb Alloy.

Authors:  Yoshimitsu Okazaki; Shin-Ichi Katsuda
Journal:  Materials (Basel)       Date:  2021-02-04       Impact factor: 3.623

7.  Clinical and Radiological Outcomes of Rectangular Tapered Cementless Stem According to Proximal Femoral Geometry in Elderly Asian Patients.

Authors:  Joon Soon Kang; Sang Hyun Ko; Yeop Na; Yung Hun Youn
Journal:  Hip Pelvis       Date:  2019-11-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.