Literature DB >> 24068541

Elevated cytokine expression of different PEEK wear particles compared to UHMWPE in vivo.

V Lorber1, A C Paulus, A Buschmann, B Schmitt, T M Grupp, V Jansson, Sandra Utzschneider.   

Abstract

Due to their mechanical properties, there has been growing interest in poly-ether-ether-ketone (PEEK) and its composites as bearing material in total and unicompartmental knee arthroplasty. The aim of this study was to analyze the biological activity of wear particles of two different (pitch and PAN) carbon-fiber-reinforced- (CFR-) PEEK varieties in comparison to ultra-high-molecular-weight-polyethylene (UHMWPE) in vivo. The authors hypothesized no difference between the used biomaterials. Wear particle suspensions of the particulate biomaterials were injected into knee joints of Balb/c mice, which were sacrificed after seven days. The cytokine expression (IL-1β, IL-6, TNF-α) was analyzed immunohistochemically in the synovial layer, the adjacent bone marrow and the articular cartilage. Especially in the bone marrow of the two CFR-PEEK varieties there were increased cytokine expressions compared to the control and UHMWPE group. Furthermore, in the articular cartilage the CFR-PEEK pitch group showed an enhanced cytokine expression, which could be a negative predictor for the use in unicondylar knee systems. As these data suggest an increased proinflammatory potential of CFR-PEEK and its composites in vivo, the initial hypothesis had to be refuted. Summarizing these results, CFR-PEEK seems not to be an attractive alternative to UHMWPE as a bearing material, especially in unicompartmental knee arthroplasty.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24068541     DOI: 10.1007/s10856-013-5037-8

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  35 in total

Review 1.  Particles and periimplant bone resorption.

Authors:  Thomas W Bauer
Journal:  Clin Orthop Relat Res       Date:  2002-12       Impact factor: 4.176

2.  The role of adsorbed endotoxin in particle-induced stimulation of cytokine release.

Authors:  David R Cho; Arun S Shanbhag; Chi-Yuan Hong; George R Baran; Steven R Goldring
Journal:  J Orthop Res       Date:  2002-07       Impact factor: 3.494

3.  Pre-clinical studies to validate the MITCH PCR Cup: a flexible and anatomically shaped acetabular component with novel bearing characteristics.

Authors:  Ahmed M H Latif; Aude Mehats; Martyn Elcocks; Neil Rushton; Richard E Field; Eric Jones
Journal:  J Mater Sci Mater Med       Date:  2007-11-08       Impact factor: 3.896

4.  Suppression of osteoblast function by titanium particles.

Authors:  J Yao; G Cs-Szabó; J J Jacobs; K E Kuettner; T T Glant
Journal:  J Bone Joint Surg Am       Date:  1997-01       Impact factor: 5.284

5.  Inflammatory response against different carbon fiber-reinforced PEEK wear particles compared with UHMWPE in vivo.

Authors:  Sandra Utzschneider; Fabian Becker; Thomas M Grupp; Birte Sievers; Alexander Paulus; Oliver Gottschalk; Volkmar Jansson
Journal:  Acta Biomater       Date:  2010-06-08       Impact factor: 8.947

6.  Particles of all sizes provoke inflammatory responses in vivo.

Authors:  S P Zysk; H H Gebhard; T Kalteis; M Schmitt-Sody; V Jansson; K Messmer; A Veihelmann
Journal:  Clin Orthop Relat Res       Date:  2005-04       Impact factor: 4.176

7.  Biological response to chopped-carbon-fiber-reinforced peek.

Authors:  K A Jockisch; S A Brown; T W Bauer; K Merritt
Journal:  J Biomed Mater Res       Date:  1992-02

8.  Flow cytometric analysis of macrophage response to ceramic and polyethylene particles: effects of size, concentration, and composition.

Authors:  I Catelas; O L Huk; A Petit; D J Zukor; R Marchand; L Yahia
Journal:  J Biomed Mater Res       Date:  1998-09-15

9.  Influence of orthopedic particulate biomaterials on inflammation and synovial microcirculation in the murine knee joint.

Authors:  Stefan P Zysk; Harry Gebhard; Wolfgang Plitz; G H Buchhorn; Christoph M Sprecher; Volkmar Jansson; Konrad Messmer; Andreas Veihelmann
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2004-10-15       Impact factor: 3.368

10.  An 8- to 10-year review of the Rotaglide total knee replacement.

Authors:  M D Horwitz; S Awan; M B Chatoo; D J Stott; D P Powles
Journal:  Int Orthop       Date:  2007-12-13       Impact factor: 3.075

View more
  9 in total

1.  Biological activity and migration of wear particles in the knee joint: an in vivo comparison of six different polyethylene materials.

Authors:  S Utzschneider; V Lorber; M Dedic; A C Paulus; C Schröder; O Gottschalk; M Schmitt-Sody; V Jansson
Journal:  J Mater Sci Mater Med       Date:  2014-02-22       Impact factor: 3.896

2.  Exposure of articular chondrocytes to wear particles induces phagocytosis, differential inflammatory gene expression, and reduced proliferation.

Authors:  Michael D Kurdziel; Meagan Salisbury; Lige Kaplan; Tristan Maerz; Kevin C Baker
Journal:  J Mater Sci Mater Med       Date:  2017-05-22       Impact factor: 3.896

3.  Preferential CD8 rather than CD4 T-cell response to wear particles of polyether-ether-ketone and highly cross-linked polyethylene.

Authors:  Zhe Du; Shujun Wang; You Wang
Journal:  RSC Adv       Date:  2018-01-09       Impact factor: 4.036

4.  Polyethylene wear particles induce TLR 2 upregulation in the synovial layer of mice.

Authors:  A C Paulus; J Frenzel; A Ficklscherer; B P Roßbach; C Melcher; V Jansson; S Utzschneider
Journal:  J Mater Sci Mater Med       Date:  2013-11-19       Impact factor: 3.896

Review 5.  The Biologic Response to Polyetheretherketone (PEEK) Wear Particles in Total Joint Replacement: A Systematic Review.

Authors:  Ashley A Stratton-Powell; Kinga M Pasko; Claire L Brockett; Joanne L Tipper
Journal:  Clin Orthop Relat Res       Date:  2016-07-18       Impact factor: 4.176

6.  Histopathological Analysis of PEEK Wear Particle Effects on the Synovial Tissue of Patients.

Authors:  A C Paulus; S Haßelt; V Jansson; A Giurea; H Neuhaus; T M Grupp; S Utzschneider
Journal:  Biomed Res Int       Date:  2016-08-16       Impact factor: 3.411

7.  Analysis of Carbon Fiber Reinforced PEEK Hinge Mechanism Articulation Components in a Rotating Hinge Knee Design: A Comparison of In Vitro and Retrieval Findings.

Authors:  Ronja A Schierjott; Alexander Giurea; Hans-Joachim Neuhaus; Jens Schwiesau; Andreas M Pfaff; Sandra Utzschneider; Gianluca Tozzi; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2016-12-22       Impact factor: 3.411

8.  Influence of the Surface Roughness of PEEK GRF30 and Ti6Al4V SLM on the Viability of Primary Human Osteoblasts Determined by the MTT Test.

Authors:  Piotr Prochor; Żaneta Anna Mierzejewska
Journal:  Materials (Basel)       Date:  2019-12-13       Impact factor: 3.623

9.  The Effects of Cyclic Loading and Motion on the Implant-Cement Interface and Cement Mantle of PEEK and Cobalt-Chromium Femoral Total Knee Arthroplasty Implants: A Preliminary Study.

Authors:  Lennert de Ruiter; Raelene M Cowie; Louise M Jennings; Adam Briscoe; Dennis Janssen; Nico Verdonschot
Journal:  Materials (Basel)       Date:  2020-07-26       Impact factor: 3.623

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.