Literature DB >> 1562421

Cementless prosthesis of the hip joint with "spongy metal" surface. A prospective study.

W Plötz1, R Gradinger, H Rechl, R Ascherl, S Wicke-Wittenius, E Hipp.   

Abstract

Our investigations in human specimens and animal experiments show that prostheses with a spongy metal surface can become fixed by bony ingrowth to varying degrees. After consistent clinical and radiological follow-up over 12-65 months (mean 34 months) in a prospective study of 100 consecutive patients in whom 106 cementless total hip replacements had been carried out, we were able to show that after 1 year 82% of patients were pain-free with the prosthesis fixed by bony ingrowth, 8% were pain-free with the prosthesis fixed by dense fibrous tissue and 10% were not pain-free, but did not want revision surgery. Thigh pain decreased steadily from 53% 3 months postoperatively to 6.6% 15 months after operation. We believe that, when the implantation technique is exact, a high percentage of cementless spongy metal prostheses are fixed by bony ingrowth, and that a cementless prosthesis should be implanted only in patients under 60 years of age without osteoporosis.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1562421     DOI: 10.1007/bf00443476

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  25 in total

1.  Cementless acetabular components.

Authors:  C A Engh; W L Griffin; C L Marx
Journal:  J Bone Joint Surg Br       Date:  1990-01

2.  Complete replacement arthroplasty of the hip by the ring ring prosthesis. By P.A. Ring, 1968.

Authors: 
Journal:  Clin Orthop Relat Res       Date:  1988-10       Impact factor: 4.176

3.  [Experiences with cement-free implantation of the Zweymüller/Endler and Zweymüller total hip joint endoprosthesis. Indications, results, complications and modification of periarticular ossification by diphosphonate (ethylidene-1-hydroxy-1,1-diphosphonate)].

Authors:  H O Dustmann; G Godolias
Journal:  Z Orthop Ihre Grenzgeb       Date:  1988 May-Jun

4.  [Experiences with the Judet type cement-free hip joint endoprosthesis].

Authors:  R Frisch; W Schmehl; J Polster
Journal:  Z Orthop Ihre Grenzgeb       Date:  1985 May-Jun

5.  [Cast metal spongioid bone implants in animal experiments].

Authors:  M Krüger; E J Henssge; D Sellin
Journal:  Z Orthop Ihre Grenzgeb       Date:  1985 Nov-Dec

6.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

7.  A comparative study of porous coatings in a weight-bearing total hip-arthroplasty model.

Authors:  T M Turner; D R Sumner; R M Urban; D P Rivero; J O Galante
Journal:  J Bone Joint Surg Am       Date:  1986-12       Impact factor: 5.284

8.  Hip arthroplasty with a Moore prosthesis with porous coating. A five-year study.

Authors:  C A Engh
Journal:  Clin Orthop Relat Res       Date:  1983-06       Impact factor: 4.176

9.  The madreporic cementless total hip arthroplasty. New experimental data and a seven-year clinical follow-up study.

Authors:  G Lord; P Bancel
Journal:  Clin Orthop Relat Res       Date:  1983-06       Impact factor: 4.176

10.  Clinical aspects of osseointegration in joint replacement. A histological study of titanium implants.

Authors:  L Linder; A Carlsson; L Marsal; L M Bjursten; P I Brånemark
Journal:  J Bone Joint Surg Br       Date:  1988-08
View more
  3 in total

1.  Pre-clinical studies to validate the MITCH PCR Cup: a flexible and anatomically shaped acetabular component with novel bearing characteristics.

Authors:  Ahmed M H Latif; Aude Mehats; Martyn Elcocks; Neil Rushton; Richard E Field; Eric Jones
Journal:  J Mater Sci Mater Med       Date:  2007-11-08       Impact factor: 3.896

2.  Effect of proximal femoral osteoporosis on cementless hip arthroplasty: a short-term clinical analysis.

Authors:  Xian-feng Lou; Yu-hong Li; Xiang-jin Lin
Journal:  J Zhejiang Univ Sci B       Date:  2007-01       Impact factor: 3.066

3.  [Results of implantation of uncemented porous metal hip prostheses].

Authors:  M Runkel; U Jaeger; K Wenda; J Degreif; L Rudig; G Ritter
Journal:  Unfallchirurgie       Date:  1994-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.