Literature DB >> 8478354

Mechanical and textural properties of pelvic trabecular bone.

M Dalstra1, R Huiskes, A Odgaard, L van Erning.   

Abstract

So far, virtually nothing is known about the mechanical properties of pelvic trabecular bone. In this study, several techniques have been used to establish some insight in these properties. Dual-energy quantitative computer tomography (DEQCT) was used to look at the distribution of bone densities throughout the pelvic bone and nondestructive mechanical testing was used to obtain Young's moduli and Poisson's ratios in three orthogonal directions for cubic specimens of pelvic trabecular bone. The same specimens were then used for stereological measurements to obtain volume fractions and the spatial orientations of the mean intercept lengths. The combined data on the mechanical tests and the stereological measurements made it possible to calculate Young's moduli and Poisson's ratios for the specimens' principal material axes. DEQCT showed that bone densities within a pelvic bone are significantly higher in the superior part of the acetabulum, extending to the sacroiliac joint area and, secondly, in the area of the pubic symphysis. Volume fractions found for the specimens did not exceed 20%. This may be considered rather low when compared to values reported in the literature for trabecular bone of femoral or tibial origin, but the values do lie in the same range as vertebral trabecular bone. With the volume fraction as its primary predictor, values of Young's moduli were also low. For most specimens these values were not higher than 100 MPa, with an occasional peak of 250 MPa. Looking at the ratio of the highest and lowest Young's modulus or at the components of the fabric tensor, it can be concluded that pelvic trabecular bone is not highly anisotropic. On an average, Poisson's ratio was found to be closer to 0.2 rather than 0.3, which is in accordance with other studies on Poisson's ratio of trabecular bone.

Entities:  

Mesh:

Year:  1993        PMID: 8478354     DOI: 10.1016/0021-9290(93)90014-6

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  41 in total

1.  Oreopithecus was a bipedal ape after all: evidence from the iliac cancellous architecture.

Authors:  L Rook; L Bondioli; M Köhler; S Moyà-Solà; R Macchiarelli
Journal:  Proc Natl Acad Sci U S A       Date:  1999-07-20       Impact factor: 11.205

2.  Minimum solid area models applied to the prediction of Young's modulus for cancellous bone.

Authors:  K U O'Kelly; A J Carr; B A O McCormack
Journal:  J Mater Sci Mater Med       Date:  2003-04       Impact factor: 3.896

3.  Defining the normal acetabular vault in adult males and females using a novel three-dimensional model.

Authors:  Wael K Barsoum; Travis Smith; Leonard Buller; Feno Monaco; Alison Klika; Constantine Mavroudis; Jason Bryan
Journal:  J Anat       Date:  2012-06-07       Impact factor: 2.610

Review 4.  [New techniques for the diagnosis of osteoporosis].

Authors:  A S Issever; T M Link
Journal:  Radiologe       Date:  2006-10       Impact factor: 0.635

5.  Pre-clinical studies to validate the MITCH PCR Cup: a flexible and anatomically shaped acetabular component with novel bearing characteristics.

Authors:  Ahmed M H Latif; Aude Mehats; Martyn Elcocks; Neil Rushton; Richard E Field; Eric Jones
Journal:  J Mater Sci Mater Med       Date:  2007-11-08       Impact factor: 3.896

6.  Validation of finite element predictions of cartilage contact pressure in the human hip joint.

Authors:  Andrew E Anderson; Benjamin J Ellis; Steve A Maas; Christopher L Peters; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2008-10       Impact factor: 2.097

7.  Normal and osteoarthritic hip joint mechanical behaviour: a comparison study.

Authors:  A Pustoc'h; L Cheze
Journal:  Med Biol Eng Comput       Date:  2009-02-13       Impact factor: 2.602

8.  Development of the fetal ilium--challenging concepts of bipedality.

Authors:  Craig A Cunningham; Sue M Black
Journal:  J Anat       Date:  2008-11-12       Impact factor: 2.610

9.  Anticipating bipedalism: trabecular organization in the newborn ilium.

Authors:  Craig A Cunningham; Sue M Black
Journal:  J Anat       Date:  2009-06       Impact factor: 2.610

10.  Sensitivity and ex vivo validation of finite element models of the domestic pig cranium.

Authors:  Jen A Bright; Emily J Rayfield
Journal:  J Anat       Date:  2011-07-01       Impact factor: 2.610

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.