Acetabular augmentation ring for recurrent dislocation of total hip arthroplasty: 60% stability rate after an average follow-up of 74 months.

B H Bosker1, H B Ettema, C C P M Verheyen, R M Castelein.   

Abstract

Between 1988 and 2002, 47 patients (50 hips) were treated with acetabular shell augmentation arthroplasty for recurrent idiopathic dislocation of their total hip arthroplasty. Apparent causes for dislocation such as deep infection, component malposition, or polyethylene wear were excluded. Follow-up averaged 74 months (range, 12-178 months), and clinically, 30 hips (60%) did not present a subsequent dislocation at most recent follow-up. In five hips (10%), deep infection after the augmentation procedure necessitated removal of the entire prosthesis. In our opinion, this technique cannot be recommended as it has an unacceptable failure and high infection rate.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17952437      PMCID: PMC2899253          DOI: 10.1007/s00264-007-0456-0

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  15 in total

1.  Recurrent hip arthroplasty dislocation: good outcome after cup augmentation in 20 patients followed for 2 years.

Authors:  A Philip Charlwood; Neville W Thompson; Neill S Thompson; David E Beverland; James R Nixon
Journal:  Acta Orthop Scand       Date:  2002-10

2.  A simplified method to determine acetabular cup anteversion from plain radiographs.

Authors:  Karl-Heinz Widmer
Journal:  J Arthroplasty       Date:  2004-04       Impact factor: 4.757

3.  A prosthesis augmentation device for the prevention of recurrent hip dislocation. A preliminary report.

Authors:  P Watson; J R Nixon; R A Mollan
Journal:  Clin Orthop Relat Res       Date:  1991-06       Impact factor: 4.176

4.  Failure of acetabular augmentation for recurrent dislocation after hip arthroplasty. Report of 3 cases.

Authors:  J B Williamson; C S Galasko; D I Rowley
Journal:  Acta Orthop Scand       Date:  1989-12

5.  Recurrent dislocation following hip replacement: brief report.

Authors:  G P Graham; A I Jenkins; W Mintowt-Czyz
Journal:  J Bone Joint Surg Br       Date:  1988-08

6.  Acetabular augmentation for dislocation of the prosthetic hip. A 3 (1-6)-year follow-up of 16 patients.

Authors:  N Bradbury; G F Milligan
Journal:  Acta Orthop Scand       Date:  1994-08

7.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

8.  Acetabular augmentation for the treatment of unstable total hip arthroplasties.

Authors:  J E Nicholl; S R Koka; I W Bintcliffe; A K Addison
Journal:  Ann R Coll Surg Engl       Date:  1999-03       Impact factor: 1.891

9.  Classification and treatment of dislocations of total hip arthroplasty.

Authors:  L D Dorr; A W Wolf; R Chandler; J P Conaty
Journal:  Clin Orthop Relat Res       Date:  1983-03       Impact factor: 4.176

10.  Dislocation after total hip arthroplasty. Treatment with an above-knee hip spica cast.

Authors:  J F Williams; M J Gottesman; T H Mallory
Journal:  Clin Orthop Relat Res       Date:  1982 Nov-Dec       Impact factor: 4.176

View more
  8 in total

1.  Unstable hip arthroplasties. A prospective cohort study on seventy dislocating hips followed up for four years.

Authors:  Olle Wallner; André Stark; Olle Muren; Thomas Eisler; Olof Sköldenberg
Journal:  Int Orthop       Date:  2014-11-13       Impact factor: 3.075

2.  Combined anteversion technique reduced the dislocation in cementless total hip arthroplasty.

Authors:  Yasuharu Nakashima; Masanobu Hirata; Mio Akiyama; Takashi Itokawa; Takuaki Yamamoto; Goro Motomura; Masanobu Ohishi; Satoshi Hamai; Yukihide Iwamoto
Journal:  Int Orthop       Date:  2013-09-13       Impact factor: 3.075

3.  A cadaveric study of posterior dislocation after total hip replacement-effects of head diameter and acetabular anteversion.

Authors:  Fu Yuen Ng; Jiang Tao Zhang; Kwong Yuen Chiu; Chun Hoi Yan
Journal:  Int Orthop       Date:  2010-02-24       Impact factor: 3.075

4.  Direction of hip arthroplasty dislocation in patients with femoral neck fractures.

Authors:  Anders Enocson; Gunilla Lapidus; Hans Törnkvist; Jan Tidermark; Lasse J Lapidus
Journal:  Int Orthop       Date:  2010-01-22       Impact factor: 3.075

5.  The risk of dislocation after total hip arthroplasty for fractures is decreased with retentive cups.

Authors:  Philippe Hernigou; Louis Ratte; François Roubineau; Jacques Pariat; Guillaume Mirouse; Isaac Guissou; Jerome Allain; Charles Henri Flouzat Lachaniette
Journal:  Int Orthop       Date:  2013-05-12       Impact factor: 3.075

6.  Outcomes for cemented dual mobility cup to treat recurrent instability; A UK case series.

Authors:  Andrew Neil Wheelton; Darren Myatt; Anthony Thomas Helm
Journal:  J Orthop       Date:  2019-02-28

7.  Acetabular Lip Augmentation Devices for the Unstable Total Hip Replacement-A Systematic Review.

Authors:  Fergus J McCabe; Martin Kelly; Conor Farrell; Muthana Abdelhalim; John F Quinlan
Journal:  Arthroplast Today       Date:  2021-10-28

8.  Dual mobility acetabular component in revision total hip arthroplasty for persistent dislocation: no dislocations in 50 hips after 1-5 years.

Authors:  M van Heumen; P J C Heesterbeek; B A Swierstra; G G Van Hellemondt; J H M Goosen
Journal:  J Orthop Traumatol       Date:  2014-09-24
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.