Literature DB >> 30906127

Outcomes for cemented dual mobility cup to treat recurrent instability; A UK case series.

Andrew Neil Wheelton1,2, Darren Myatt1, Anthony Thomas Helm1.   

Abstract

OBJECTIVES: Recurrent dislocation of Total Hip Replacement (THR) is often multifactorial and remains a significant surgical challenge with a significant risk of further instability. Dual Mobility Cups (DMC) have been used widely with good long term results in France with few studies in the British literature, especially assessing their use for recurrent instability. We set out to assess whether recurrent instability can be successfully treated solely with revision of acetabular component to a dual mobility cup.
METHODS: We retrospectively reviewed a prospectively collected electronic database for all consecutive dual mobility cups implanted to address recurrently instability in THR. Radiological and clinical data have been analysed.
RESULTS: From September 2013 to September 2017 54 dual mobility cups have been implanted, mean age 78 (range 49-97). 47 were 1st time revision procedures, 7 were following previous revisions including 5 failed PLADs. Average time post primary was 10 years (range 8 months-23 years). Twenty cases are cement in cement revisions which has become our primary technique for revision of cemented cups. Mean follow up is 1.9 years (range 6 months-5 years), 37 cases have 2 year follow up available. 8 patients have died. There have been no episodes of further instability. One patient has had reoperation for infection (1st stage revision).
CONCLUSIONS: This series demonstrates satisfactory early to mid-term results for the use of dual mobility cups to treat recurrent instability. The technique is particularly useful when femoral components are well fixed and can be used with monoblock implants such as the Charnley stem. Cement in cement revision is a convenient technique and potentially reduces complications and cost. Further analysis of longer term data is required but these results suggests this could be a valid solution to a complex problem.

Entities:  

Keywords:  Arthroplasty; Dislocation; Dual mobility; Hip; Orthopaedics; Revision

Year:  2019        PMID: 30906127      PMCID: PMC6411649          DOI: 10.1016/j.jor.2019.02.025

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  19 in total

1.  Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years' follow-up.

Authors:  F Leiber-Wackenheim; B Brunschweiler; M Ehlinger; A Gabrion; P Mertl
Journal:  Orthop Traumatol Surg Res       Date:  2011-01-26       Impact factor: 2.256

2.  Classification and management of the unstable total hip arthroplasty.

Authors:  Glenn D Wera; Nick T Ting; Mario Moric; Wayne G Paprosky; Scott M Sporer; Craig J Della Valle
Journal:  J Arthroplasty       Date:  2011-10-29       Impact factor: 4.757

3.  Acetabular augmentation ring for recurrent dislocation of total hip arthroplasty: 60% stability rate after an average follow-up of 74 months.

Authors:  B H Bosker; H B Ettema; C C P M Verheyen; R M Castelein
Journal:  Int Orthop       Date:  2007-10-19       Impact factor: 3.075

Review 4.  Outcome of treatment for dislocation after primary total hip replacement.

Authors:  R S Kotwal; M Ganapathi; A John; M Maheson; S A Jones
Journal:  J Bone Joint Surg Br       Date:  2009-03

5.  The epidemiology of revision total hip arthroplasty in the United States.

Authors:  Kevin J Bozic; Steven M Kurtz; Edmund Lau; Kevin Ong; Thomas P Vail; Daniel J Berry
Journal:  J Bone Joint Surg Am       Date:  2009-01       Impact factor: 5.284

6.  Is an algorithmic approach to the treatment of recurrent dislocation after THA effective?

Authors:  Ehsan Saadat; Glenn Diekmann; Steven Takemoto; Michael D Ries
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

7.  Dislocation after revision total hip arthroplasty : an analysis of risk factors and treatment options.

Authors:  Gregory M Alberton; Whitney A High; Bernard F Morrey
Journal:  J Bone Joint Surg Am       Date:  2002-10       Impact factor: 5.284

8.  High failure rate of a constrained acetabular liner in revision total hip arthroplasty.

Authors:  Craig J Della Valle; Dennis Chang; Scott Sporer; Richard A Berger; Aaron G Rosenberg; Wayne G Paprosky
Journal:  J Arthroplasty       Date:  2005-10       Impact factor: 4.757

Review 9.  The dislocating hip arthroplasty: prevention and treatment.

Authors:  Preetesh D Patel; Aaron Potts; Mark I Froimson
Journal:  J Arthroplasty       Date:  2007-06       Impact factor: 4.757

10.  Dual-mobility cups for revision due to instability are associated with a low rate of re-revisions due to dislocation: 228 patients from the Swedish Hip Arthroplasty Register.

Authors:  Nils P Hailer; Rüdiger J Weiss; André Stark; Johan Kärrholm
Journal:  Acta Orthop       Date:  2012-11-01       Impact factor: 3.717

View more
  2 in total

1.  Dual-Mobility Cup Total Hip Arthroplasty for Displaced Femoral Neck Fractures: A Retrospective Study With a Median Follow-Up of 5 Years.

Authors:  Zhenfa Zhang; Guixing Xu; Lei Cao; Wei Sun; Xianshang Zeng; Nana Xiong; Shuxin Wang; Weiguang Yu; Qilong Liu; Huanyi Lin
Journal:  Geriatr Orthop Surg Rehabil       Date:  2021-04-30

2.  Risk factors and modes of failure in the modern dual mobility implant. A systematic review and meta-analysis.

Authors:  Fu-Yuan Pai; Hsuan-Hsiao Ma; Te-Feng Arthur Chou; Tsan-Wen Huang; Kuo-Chin Huang; Shang-Wen Tsai; Cheng-Fong Chen; Wei-Ming Chen
Journal:  BMC Musculoskelet Disord       Date:  2021-06-14       Impact factor: 2.362

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.