Literature DB >> 17893208

Radiation dose-reduction strategies for neuroradiology CT protocols.

A B Smith1, W P Dillon, R Gould, M Wintermark.   

Abstract

Within the past 2 decades, the number of CT examinations performed has increased almost 10-fold. This is in large part due to advances in multidetector-row CT technology, which now allows faster image acquisition and improved isotropic imaging. The increased use, along with multidetector technique, has led to a significantly increased radiation dose to the patient from CT studies. This places increased responsibility on the radiologist to ensure that CT examinations are indicated and that the "as low as reasonably achievable" concept is adhered to. Neuroradiologists are familiar with factors that affect patient dose such as pitch, milliamperes, kilovolt peak (kVp), collimation, but with increasing attention being given to dose reduction, they are looking for additional ways to further reduce the radiation associated with their CT protocols. In response to increasing concern, CT manufacturers have developed dose-reduction tools, such as dose modulation, in which the tube current is adjusted along with the CT acquisition, according to patient's attenuation. This review will describe the available techniques for reducing dose associated with neuroradiologic CT imaging protocols.

Entities:  

Mesh:

Year:  2007        PMID: 17893208      PMCID: PMC8134195          DOI: 10.3174/ajnr.A0814

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  20 in total

1.  Multi-detector row CT: radiation dose characteristics.

Authors:  Leena M Hamberg; James T Rhea; George J Hunter; James H Thrall
Journal:  Radiology       Date:  2003-03       Impact factor: 11.105

Review 2.  Radiation exposure at chest CT: a statement of the Fleischner Society.

Authors:  John R Mayo; John Aldrich; Nestor L Muller
Journal:  Radiology       Date:  2003-07       Impact factor: 11.105

3.  Low-dose CT of the abdomen: evaluation of image improvement with use of noise reduction filters pilot study.

Authors:  Mannudeep K Kalra; Michael M Maher; Dushyant V Sahani; Michael A Blake; Peter F Hahn; Gopal B Avinash; Thomas L Toth; Elkan Halpern; Sanjay Saini
Journal:  Radiology       Date:  2003-05-08       Impact factor: 11.105

4.  Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries.

Authors:  Amy Berrington de González; Sarah Darby
Journal:  Lancet       Date:  2004-01-31       Impact factor: 79.321

5.  Estimated risks of radiation-induced fatal cancer from pediatric CT.

Authors:  D Brenner; C Elliston; E Hall; W Berdon
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

6.  Chest CT performed with z-axis modulation: scanning protocol and radiation dose.

Authors:  Mannudeep K Kalra; Stefania Rizzo; Michael M Maher; Elkan F Halpern; Thomas L Toth; Jo-Anne O Shepard; Suzanne L Aquino
Journal:  Radiology       Date:  2005-10       Impact factor: 11.105

Review 7.  Strategies for CT radiation dose optimization.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Leena M Hamberg; Michael A Blake; Jo-Anne Shepard; Sanjay Saini
Journal:  Radiology       Date:  2004-01-22       Impact factor: 11.105

8.  Nation-wide survey on radiation doses in diagnostic and interventional radiology in Switzerland in 1998.

Authors:  A Aroua; B Burnand; I Decka; J P Vader; J F Valley
Journal:  Health Phys       Date:  2002-07       Impact factor: 1.316

Review 9.  Spiral CT and radiation dose.

Authors:  H Imhof; N Schibany; A Ba-Ssalamah; C Czerny; A Hojreh; F Kainberger; C Krestan; H Kudler; I Nöbauer; R Nowotny
Journal:  Eur J Radiol       Date:  2003-07       Impact factor: 3.528

10.  CT scanning: a major source of radiation exposure.

Authors:  Philip W Wiest; Julie A Locken; Philip H Heintz; Fred A Mettler
Journal:  Semin Ultrasound CT MR       Date:  2002-10       Impact factor: 1.875

View more
  31 in total

Review 1.  Recognition, assessment, and treatment of non-union after surgical fixation of fractures: emphasis on 3D CT.

Authors:  Cuneyt Calisir; Laura M Fayad; John A Carrino; Elliot K Fishman
Journal:  Jpn J Radiol       Date:  2011-12-10       Impact factor: 2.374

2.  The use of adaptive statistical iterative reconstruction in pediatric head CT: a feasibility study.

Authors:  G A Vorona; G Zuccoli; T Sutcavage; B L Clayton; R C Ceschin; A Panigrahy
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-24       Impact factor: 3.825

3.  Radiation doses of cerebral blood volume measurements using C-arm CT: A phantom study.

Authors:  W F Chu; C J Lin; W S Chen; S C Hung; C F Chiu; T H Wu; W Y Guo
Journal:  AJNR Am J Neuroradiol       Date:  2013-12-26       Impact factor: 3.825

4.  Radiation dose reduction in time-resolved CT angiography using highly constrained back projection reconstruction.

Authors:  Mark Supanich; Yinghua Tao; Brian Nett; Kari Pulfer; Jiang Hsieh; Patrick Turski; Charles Mistretta; Howard Rowley; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2009-06-30       Impact factor: 3.609

5.  An education and training programme for radiological institutes: impact on the reduction of the CT radiation dose.

Authors:  Sebastian T Schindera; Reto Treier; Gabriel von Allmen; Claude Nauer; Philipp R Trueb; Peter Vock; Zsolt Szucs-Farkas
Journal:  Eur Radiol       Date:  2011-05-31       Impact factor: 5.315

6.  Lowering the dose in head CT using adaptive statistical iterative reconstruction.

Authors:  K Kilic; G Erbas; M Guryildirim; M Arac; E Ilgit; B Coskun
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-11       Impact factor: 3.825

7.  Signal-to-noise ratio and dose to the lens of the eye for computed tomography examination of the brain using an automatic tube current modulation system.

Authors:  Supawitoo Sookpeng; Chitsanupong Butdee
Journal:  Emerg Radiol       Date:  2016-12-02

8.  Can iterative reconstruction improve imaging quality for lower radiation CT perfusion? Initial experience.

Authors:  C J Lin; T H Wu; C H Lin; S C Hung; C F Chiu; M-J Liu; M M H Teng; F C Chang; W Y Guo; C Y Chang
Journal:  AJNR Am J Neuroradiol       Date:  2013-04-11       Impact factor: 3.825

9.  Effect of CTA Tube Current on Spot Sign Detection and Accuracy for Prediction of Intracerebral Hemorrhage Expansion.

Authors:  A Morotti; J M Romero; M J Jessel; H B Brouwers; R Gupta; K Schwab; A Vashkevich; A Ayres; C D Anderson; M E Gurol; A Viswanathan; S M Greenberg; J Rosand; J N Goldstein
Journal:  AJNR Am J Neuroradiol       Date:  2016-05-19       Impact factor: 3.825

10.  Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction.

Authors:  Yan Liu; Jianhua Ma; Yi Fan; Zhengrong Liang
Journal:  Phys Med Biol       Date:  2012-11-15       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.