Literature DB >> 12832586

Low-dose CT of the abdomen: evaluation of image improvement with use of noise reduction filters pilot study.

Mannudeep K Kalra1, Michael M Maher, Dushyant V Sahani, Michael A Blake, Peter F Hahn, Gopal B Avinash, Thomas L Toth, Elkan Halpern, Sanjay Saini.   

Abstract

A prospective assessment of improvement in image quality at low-radiation-dose computed tomography (CT) of the abdomen by using noise reduction filters was performed. CT images acquired at standard and 50% reduced tube current were processed with six noise reduction filters and evaluated by three radiologists for image noise, sharpness, contrast, and overall image quality in terms of abdominal organ depiction. Quantitative image noise and contrast-to-noise ratio were measured. Baseline low-dose CT images were significantly worse than standard-dose CT images (P <.05). A statistically significant reduction of noise in low-dose images processed with three filters was noted. In conclusion, use of noise reduction filters decreased image noise at low-dose CT.

Entities:  

Mesh:

Year:  2003        PMID: 12832586     DOI: 10.1148/radiol.2281020693

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  33 in total

1.  The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography.

Authors:  F Tatsugami; M Matsuki; G Nakai; Y Inada; S Kanazawa; Y Takeda; H Morita; H Takada; S Yoshikawa; K Fukumura; Y Narumi
Journal:  Br J Radiol       Date:  2012-01-17       Impact factor: 3.039

2.  Low-dose CT of the lung: potential value of iterative reconstructions.

Authors:  Stephan Baumueller; Anna Winklehner; Christoph Karlo; Robert Goetti; Thomas Flohr; Erich W Russi; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2012-06-15       Impact factor: 5.315

3.  Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter.

Authors:  Harald Seifarth; Rainer Raupach; Stefan Schaller; Eva Maria Fallenberg; Thomas Flohr; Walter Heindel; Roman Fischbach; David Maintz
Journal:  Eur Radiol       Date:  2005-02-12       Impact factor: 5.315

4.  Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique.

Authors:  Masaki Katsura; Izuru Matsuda; Masaaki Akahane; Jiro Sato; Hiroyuki Akai; Koichiro Yasaka; Akira Kunimatsu; Kuni Ohtomo
Journal:  Eur Radiol       Date:  2012-04-27       Impact factor: 5.315

Review 5.  Radiation dose-reduction strategies for neuroradiology CT protocols.

Authors:  A B Smith; W P Dillon; R Gould; M Wintermark
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

6.  Combining automated attenuation-based tube voltage selection and iterative reconstruction: a liver phantom study.

Authors:  Daniela B Husarik; Sebastian T Schindera; Fabian Morsbach; Natalie Chuck; Burkhardt Seifert; Zsolt Szucs-Farkas; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2013-10-24       Impact factor: 5.315

7.  Reduction of the radiation dose for multidetector row CT angiography of cerebral aneurysms using an edge-preserving adaptive filter: a vascular phantom study.

Authors:  S Kakeda; Y Korogi; M Ogawa; K Otsubo; Y Morishita
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-05       Impact factor: 3.825

8.  Reduced-dose abdominopelvic CT using hybrid iterative reconstruction in suspected left-sided colonic diverticulitis.

Authors:  Azien Laqmani; Simon Veldhoen; Simon Dulz; Thorsten Derlin; Cyrus Behzadi; Jakob Schmidt-Holtz; Felicia Wassenberg; Susanne Sehner; Hans-Dieter Nagel; Gerhard Adam; Marc Regier
Journal:  Eur Radiol       Date:  2015-06-13       Impact factor: 5.315

9.  Evaluation of various image reconstruction parameters in lower extremity stents using multidetector-row CT angiography: initial findings.

Authors:  Martin Heuschmid; Benjamin Wiesinger; Gunnar Tepe; Oliver Luz; Andreas F Kopp; Claus D Claussen; Stephan H Duda
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 5.315

Review 10.  Radiation exposure from chest CT: issues and strategies.

Authors:  Mannudeep K Kalra; Michael M Maher; Stefania Rizzo; David Kanarek; Jo-Anne O Shepard; Jo-Anne O Shephard
Journal:  J Korean Med Sci       Date:  2004-04       Impact factor: 2.153

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.