Literature DB >> 1774081

Simple photon diffusion analysis of the effects of multiple scattering on pulse oximetry.

J M Schmitt1.   

Abstract

Photon diffusion theory is used to derive analytical expressions that relate the ac-dc intensity ratios measured by transmission-mode and reflectance-mode pulse oximeters to arterial oxygen saturation (SaO2). The effects of multiple scattering are examined by comparing the results of the photon diffusion analysis with those obtained using an analysis based on the Beer-Lambert law which neglects scattering. We show that the difference between the average lengths of the paths travelled by red and infrared photons makes the calibration curve of oximeters sensitive to the total attenuation coefficients of the tissue in the two wavelength bands, as well as to absorption by the pulsating arterial blood. Therefore, the shape of the calibration curve is affected by tissue blood volume, source-detector placement, and other variables that change the wavelength dependence of the attenuation coefficient of the tissue. After evaluating the relationship between SaO2 and the red/IR ac-dc ratio (R) under a variety of physiological conditions, we conclude that, for oximeters utilizing fixed calibration curves based on measurements obtained from normal subjects, errors introduced by interfering variables should be less than a few percent when SaO2 exceeds 70%. Predicted errors at lower oxygen saturation values are substantially greater because R is much more sensitive to interfering variables in this measurement range.

Entities:  

Mesh:

Year:  1991        PMID: 1774081     DOI: 10.1109/10.137285

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  13 in total

1.  Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method.

Authors:  E A López-Beltrán; P L Blackshear; S M Finkelstein; J N Cohn
Journal:  Med Biol Eng Comput       Date:  1998-11       Impact factor: 2.602

Review 2.  Factors influencing fetal pulse oximetry performance.

Authors:  James L Reuss
Journal:  J Clin Monit Comput       Date:  2004-02       Impact factor: 2.502

3.  The influence of larger subcutaneous blood vessels on pulse oximetry.

Authors:  Paul D Mannheimer; Neil Michael P O'; Ewald Konecny
Journal:  J Clin Monit Comput       Date:  2004-06       Impact factor: 2.502

4.  The pulse in reflectance pulse oximetry: modeling and experimental studies.

Authors:  James L Reuss; Daniel Siker
Journal:  J Clin Monit Comput       Date:  2004-08       Impact factor: 2.502

5.  Reflectance pulse oximetry in fetal lambs: subcutaneous vessels and vasoconstriction affect its reliability.

Authors:  R Nijland; H W Jongsma; I M Verbruggen; J G Nijhuis
Journal:  J Clin Monit       Date:  1996-05

Review 6.  Basic principles of optical radiation and some common applications in anesthesia.

Authors:  D Gravenstein; S Lampotang; W Huda; A Sultan
Journal:  J Clin Monit       Date:  1996-11

7.  The effect of pulsating arteries on reflectance pulse oximetry: measurements in adults and neonates.

Authors:  R Nijland; H W Jongsma; P P van den Berg; J G Nijhuis; B Oeseburg
Journal:  J Clin Monit       Date:  1995-03

8.  Electro-optical simulator for pulse oximeters.

Authors:  G X Zhou; J M Schmitt; E C Walker
Journal:  Med Biol Eng Comput       Date:  1993-09       Impact factor: 2.602

9.  Validation of reflectance pulse oximetry: an evaluation of a new sensor in piglets.

Authors:  R Nijland; S Nierlich; H W Jongsma; J G Nijhuis; B Oeseburg; K Springer; P Mannheimer
Journal:  J Clin Monit       Date:  1997-01

10.  Miniaturized Battery-Free Wireless Systems for Wearable Pulse Oximetry.

Authors:  Jeonghyun Kim; Philipp Gutruf; Antonio M Chiarelli; Seung Yun Heo; Kyoungyeon Cho; Zhaoqian Xie; Anthony Banks; Seungyoung Han; Kyung-In Jang; Jung Woo Lee; Kyu-Tae Lee; Xue Feng; Yonggang Huang; Monica Fabiani; Gabriele Gratton; Ungyu Paik; John A Rogers
Journal:  Adv Funct Mater       Date:  2016-11-25       Impact factor: 18.808

View more