Force application during cochlear implant insertion: an analysis for improvement of surgeon technique.

Catherine A Todd1, Fazel Naghdy, Martin J Svehla.   

Abstract

Highly invasive surgical procedures, such as the implantation of a prosthetic device, require correct force delivery to achieve desirable outcomes and minimize trauma induced during the operation. Improvement in surgeon technique can reduce the chances of excessive force application and lead to optimal placement of the electrode array. The fundamental factors that affect the degree of success for cochlear implant recipients are identified through empirical methods. Insertion studies are performed to assess force administration and electrode trajectories during implantations of the Nucleus 24 Contour and Nucleus 24 Contour Advance electrodes into a synthetic model of the human Scala Tympani, using associated methods. Results confirm that the Advance Off- Stylet insertion of the soft-tipped Contour Advance electrode gives an overall reduction in insertion force. Analysis of force delivery and electrode positioning during cochlear implantation can help identify and control key factors for improvement of insertion method. Based on the findings, suggestions are made to enhance surgeon technique.

Entities:  

Mesh:

Year:  2007        PMID: 17605356     DOI: 10.1109/TBME.2007.891937

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  17 in total

1.  Determination of the curling behavior of a preformed cochlear implant electrode array.

Authors:  Thomas S Rau; Omid Majdani; Andreas Hussong; Thomas Lenarz; Martin Leinung
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-07-28       Impact factor: 2.924

2.  An automated insertion tool for cochlear implants with integrated force sensing capability.

Authors:  Jan-Philipp Kobler; Daniel Beckmann; Thomas S Rau; Omid Majdani; Tobias Ortmaier
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-05       Impact factor: 2.924

3.  Automated insertion of preformed cochlear implant electrodes: evaluation of curling behaviour and insertion forces on an artificial cochlear model.

Authors:  Thomas S Rau; Andreas Hussong; Martin Leinung; Thomas Lenarz; Omid Majdani
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-04-10       Impact factor: 2.924

4.  Patient-specific estimation of detailed cochlear shape from clinical CT images.

Authors:  H Martin Kjer; Jens Fagertun; Wilhelm Wimmer; Nicolas Gerber; Sergio Vera; Livia Barazzetti; Nerea Mangado; Mario Ceresa; Gemma Piella; Thomas Stark; Martin Stauber; Mauricio Reyes; Stefan Weber; Marco Caversaccio; Miguel Ángel González Ballester; Rasmus R Paulsen
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-01-06       Impact factor: 2.924

5.  Investigation of ultra-low insertion speeds in an inelastic artificial cochlear model using custom-made cochlear implant electrodes.

Authors:  Silke Hügl; Katharina Rülander; Thomas Lenarz; Omid Majdani; Thomas S Rau
Journal:  Eur Arch Otorhinolaryngol       Date:  2018-10-09       Impact factor: 2.503

6.  Scanning electrochemical microscopy as a novel proximity sensor for atraumatic cochlear implant insertion.

Authors:  H Watanabe; J Velmurugan; M V Mirkin; M A Svirsky; A K Lalwani; R R Llinas
Journal:  IEEE Trans Biomed Eng       Date:  2014-06       Impact factor: 4.538

7.  Visualization, measurement and modelling of the cochlea using rotating midmodiolar slice planes.

Authors:  G Jakob Lexow; Daniel Schurzig; Nils-Claudius Gellrich; Thomas Lenarz; Omid Majdani; Thomas S Rau
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-03-19       Impact factor: 2.924

8.  Force of cochlear implant electrode insertion performed by a robotic insertion tool: comparison of traditional versus Advance Off-Stylet techniques.

Authors:  Daniel Schurzig; Robert J Webster; Mary S Dietrich; Robert F Labadie
Journal:  Otol Neurotol       Date:  2010-10       Impact factor: 2.311

9.  Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion.

Authors:  Nathaniel T Greene; Jameson K Mattingly; Renee M Banakis Hartl; Daniel J Tollin; Stephen P Cass
Journal:  Otol Neurotol       Date:  2016-12       Impact factor: 2.311

10.  Design of a Tool Integrating Force Sensing With Automated Insertion in Cochlear Implantation.

Authors:  Daniel Schurzig; Robert F Labadie; Andreas Hussong; Thomas S Rau; Robert J Webster
Journal:  IEEE ASME Trans Mechatron       Date:  2011-02-22       Impact factor: 5.303

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.