Literature DB >> 17539605

Parts-per-billion mass measurement accuracy achieved through the combination of multiple linear regression and automatic gain control in a Fourier transform ion cyclotron resonance mass spectrometer.

D Keith Williams1, David C Muddiman.   

Abstract

Fourier transform ion cyclotron resonance mass spectrometry has the ability to achieve unprecedented mass measurement accuracy (MMA); MMA is one of the most significant attributes of mass spectrometric measurements as it affords extraordinary molecular specificity. However, due to space-charge effects, the achievable MMA significantly depends on the total number of ions trapped in the ion cyclotron resonance (ICR) cell for a particular measurement. Even through the use of automatic gain control (AGC), the total ion population is not constant between spectra. Multiple linear regression calibration in conjunction with AGC is utilized in these experiments to formally account for the differences in total ion population in the ICR cell between the external calibration spectra and experimental spectra. This ability allows for the extension of dynamic range of the instrument and for the mean MMA values to remain less than 1 part-per-million (ppm). In addition, multiple linear regression calibration is used to account for both differences in total ion population in the ICR cell as well as relative ion abundance of a given species, which also affords mean MMA values at the parts-per-billion (ppb) level.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17539605      PMCID: PMC2651406          DOI: 10.1021/ac0704210

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  30 in total

1.  High-mass accuracy of product ions produced by SORI-CID using a dual electrospray ionization source coupled with FTICR mass spectrometry.

Authors:  J W Flora; J C Hannis; D C Muddiman
Journal:  Anal Chem       Date:  2001-03-15       Impact factor: 6.986

2.  Baseline mass resolution of peptide isobars: a record for molecular mass resolution.

Authors:  F He; C L Hendrickson; A G Marshall
Journal:  Anal Chem       Date:  2001-02-01       Impact factor: 6.986

3.  Petroleomics: the next grand challenge for chemical analysis.

Authors:  Alan G Marshall; Ryan P Rodgers
Journal:  Acc Chem Res       Date:  2004-01       Impact factor: 22.384

4.  Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications.

Authors:  John E P Syka; Jarrod A Marto; Dina L Bai; Stevan Horning; Michael W Senko; Jae C Schwartz; Beatrix Ueberheide; Benjamin Garcia; Scott Busby; Tara Muratore; Jeffrey Shabanowitz; Donald F Hunt
Journal:  J Proteome Res       Date:  2004 May-Jun       Impact factor: 4.466

5.  The Orbitrap: a new mass spectrometer.

Authors:  Qizhi Hu; Robert J Noll; Hongyan Li; Alexander Makarov; Mark Hardman; R Graham Cooks
Journal:  J Mass Spectrom       Date:  2005-04       Impact factor: 1.982

6.  Improved mass accuracy for tandem mass spectrometry.

Authors:  Nathan K Kaiser; Gordon A Anderson; James E Bruce
Journal:  J Am Soc Mass Spectrom       Date:  2005-04       Impact factor: 3.109

7.  Sub part-per-million mass accuracy by using stepwise-external calibration in fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Richard L Wong; I Jonathan Amster
Journal:  J Am Soc Mass Spectrom       Date:  2006-08-24       Impact factor: 3.109

8.  Statistical evaluation of internal and external mass calibration laws utilized in fourier transform ion cyclotron resonance mass spectrometry.

Authors:  David C Muddiman; Ann L Oberg
Journal:  Anal Chem       Date:  2005-04-15       Impact factor: 6.986

9.  Automatic gain control in mass spectrometry using a jet disrupter electrode in an electrodynamic ion funnel.

Authors:  Jason S Page; Bogdan Bogdanov; Andrey N Vilkov; David C Prior; Michael A Buschbach; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2005-02       Impact factor: 3.109

10.  Characterization of mouse spleen cells by subtractive proteomics.

Authors:  Francisco J Dieguez-Acuna; Scott A Gerber; Shohta Kodama; Joshua E Elias; Sean A Beausoleil; Denise Faustman; Steven P Gygi
Journal:  Mol Cell Proteomics       Date:  2005-07-21       Impact factor: 5.911

View more
  15 in total

1.  Trapping radial electric field optimization in compensated FTICR cells.

Authors:  Aleksey V Tolmachev; Errol W Robinson; Si Wu; Richard D Smith; Ljiljana Paša-Toli
Journal:  J Am Soc Mass Spectrom       Date:  2011-07-06       Impact factor: 3.109

2.  Spectral accuracy and sulfur counting capabilities of the LTQ-FT-ICR and the LTQ-Orbitrap XL for small molecule analysis.

Authors:  Samantha L Blake; S Hunter Walker; David C Muddiman; David Hinks; Keith R Beck
Journal:  J Am Soc Mass Spectrom       Date:  2011-09-21       Impact factor: 3.109

3.  Improved mass accuracy for higher mass peptides by using SWIFT excitation for MALDI-FTICR mass spectrometry.

Authors:  Li Jing; Chunyan Li; Richard L Wong; Desmond A Kaplan; I Jonathan Amster
Journal:  J Am Soc Mass Spectrom       Date:  2007-10-30       Impact factor: 3.109

4.  Reply to the Comment on: "Utilizing artificial neural networks in MATLAB to achieve parts-per-billion mass measurement accuracy with a Fourier transform ion cyclotron resonance mass spectrometer" by D. Keith Williams Jr., Alexander L. Kovach, David C. Muddiman, and Kenneth W. Hanck. J. Am. Soc. Mass Spectrom. 20, 1303-1310 (2009).

Authors:  David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2014-04       Impact factor: 3.109

5.  An integrated, directed mass spectrometric approach for in-depth characterization of complex peptide mixtures.

Authors:  Alexander Schmidt; Nils Gehlenborg; Bernd Bodenmiller; Lukas N Mueller; Dave Campbell; Markus Mueller; Ruedi Aebersold; Bruno Domon
Journal:  Mol Cell Proteomics       Date:  2008-05-29       Impact factor: 5.911

6.  Ion trap with narrow aperture detection electrodes for Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Konstantin O Nagornov; Anton N Kozhinov; Oleg Y Tsybin; Yury O Tsybin
Journal:  J Am Soc Mass Spectrom       Date:  2015-03-14       Impact factor: 3.109

7.  Advanced mass calibration and visualization for FT-ICR mass spectrometry imaging.

Authors:  Donald F Smith; Andriy Kharchenko; Marco Konijnenburg; Ivo Klinkert; Ljiljana Paša-Tolić; Ron M A Heeren
Journal:  J Am Soc Mass Spectrom       Date:  2012-08-28       Impact factor: 3.109

8.  Comment on: "Utilizing artificial neural networks in MATLAB to achieve parts-per-billion mass measurement accuracy with a Fourier transform ion cyclotron resonance mass spectrometer" by D. Keith Williams Jr., Alexander L. Kovach, David C. Muddiman, and Kenneth W. Hanck. J. Am. Soc. Mass Spectrom. 20, 1303-1310 (2009).

Authors:  Charles Proctor
Journal:  J Am Soc Mass Spectrom       Date:  2014-04       Impact factor: 3.109

9.  Mass recalibration of FT-ICR mass spectrometry imaging data using the average frequency shift of ambient ions.

Authors:  Jeremy A Barry; Guillaume Robichaud; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2013-05-29       Impact factor: 3.109

10.  An improved calibration method for the matrix-assisted laser desorption/ionization-Fourier transform ion cyclotron resononance analysis of 15N-metabolically- labeled proteome digests using a mass difference approach.

Authors:  Li Jing; I Jonathan Amster
Journal:  Eur J Mass Spectrom (Chichester)       Date:  2012       Impact factor: 1.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.