Literature DB >> 16934995

Sub part-per-million mass accuracy by using stepwise-external calibration in fourier transform ion cyclotron resonance mass spectrometry.

Richard L Wong1, I Jonathan Amster.   

Abstract

A new external calibration procedure for FT-ICR mass spectrometry is presented, stepwise-external calibration. This method is demonstrated for MALDI analysis of peptide mixtures, but is applicable to any ionization method. For this procedure, the masses of analyte peaks are first accurately measured at a low trapping potential (0.63 V) using external calibration. These accurately determined (< 1 ppm accuracy) analyte peaks are used as internal calibrant points for a second mass spectrum that is acquired for the same sample at a higher trapping potential (1.0 V). The second mass spectrum has a approximately 10-fold improvement in detection dynamic range compared with the first spectrum acquired at a low trapping potential. A calibration equation that accounts for local and global space charge is shown to provide mass accuracy with external calibration that is nearly identical to that of internal calibration, without the drawbacks of experimental complexity or reduction of abundance dynamic range. For the 609 mass peaks measured using stepwise-external calibration method, the root-mean-square error is 0.9 ppm. The errors appear to have a Gaussian distribution; 99.3% of the mass errors are shown to lie within three times the sample standard deviation (2.6 ppm) of their true value.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16934995     DOI: 10.1016/j.jasms.2006.07.019

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  38 in total

1.  Broad-band ion accumulation with an internal source MALDI-FTICR-MS.

Authors:  T H Mize; I J Amster
Journal:  Anal Chem       Date:  2000-12-15       Impact factor: 6.986

2.  Internal calibration on adjacent samples (InCAS) with Fourier transform mass spectrometry.

Authors:  P B O'Connor; C E Costello
Journal:  Anal Chem       Date:  2000-12-15       Impact factor: 6.986

3.  Baseline mass resolution of peptide isobars: a record for molecular mass resolution.

Authors:  F He; C L Hendrickson; A G Marshall
Journal:  Anal Chem       Date:  2001-02-01       Impact factor: 6.986

4.  High-throughput proteomics using high-efficiency multiple-capillary liquid chromatography with on-line high-performance ESI FTICR mass spectrometry.

Authors:  Y Shen; N Tolić; R Zhao; L Pasa-Tolić; L Li; S J Berger; R Harkewicz; G A Anderson; M E Belov; R D Smith
Journal:  Anal Chem       Date:  2001-07-01       Impact factor: 6.986

Review 5.  Top-down proteomics.

Authors:  Neil L Kelleher
Journal:  Anal Chem       Date:  2004-06-01       Impact factor: 6.986

6.  Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications.

Authors:  John E P Syka; Jarrod A Marto; Dina L Bai; Stevan Horning; Michael W Senko; Jae C Schwartz; Beatrix Ueberheide; Benjamin Garcia; Scott Busby; Tara Muratore; Jeffrey Shabanowitz; Donald F Hunt
Journal:  J Proteome Res       Date:  2004 May-Jun       Impact factor: 4.466

Review 7.  Mining genomes with MS.

Authors:  J R Yates; A L McCormack; J Eng
Journal:  Anal Chem       Date:  1996-09-01       Impact factor: 6.986

8.  Space charge effects in Fourier transform mass spectrometry. Mass calibration.

Authors:  E B Ledford; D L Rempel; M L Gross
Journal:  Anal Chem       Date:  1984-12       Impact factor: 6.986

9.  Statistical evaluation of internal and external mass calibration laws utilized in fourier transform ion cyclotron resonance mass spectrometry.

Authors:  David C Muddiman; Ann L Oberg
Journal:  Anal Chem       Date:  2005-04-15       Impact factor: 6.986

10.  Automatic gain control in mass spectrometry using a jet disrupter electrode in an electrodynamic ion funnel.

Authors:  Jason S Page; Bogdan Bogdanov; Andrey N Vilkov; David C Prior; Michael A Buschbach; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2005-02       Impact factor: 3.109

View more
  16 in total

1.  Trapping radial electric field optimization in compensated FTICR cells.

Authors:  Aleksey V Tolmachev; Errol W Robinson; Si Wu; Richard D Smith; Ljiljana Paša-Toli
Journal:  J Am Soc Mass Spectrom       Date:  2011-07-06       Impact factor: 3.109

2.  Accurate mass measurement: terminology and treatment of data.

Authors:  A Gareth Brenton; A Ruth Godfrey
Journal:  J Am Soc Mass Spectrom       Date:  2010-06-19       Impact factor: 3.109

3.  Calibration function for the Orbitrap FTMS accounting for the space charge effect.

Authors:  Mikhail V Gorshkov; David M Good; Yaroslav Lyutvinskiy; Hongqian Yang; Roman A Zubarev
Journal:  J Am Soc Mass Spectrom       Date:  2010-07-07       Impact factor: 3.109

4.  Improved mass accuracy for higher mass peptides by using SWIFT excitation for MALDI-FTICR mass spectrometry.

Authors:  Li Jing; Chunyan Li; Richard L Wong; Desmond A Kaplan; I Jonathan Amster
Journal:  J Am Soc Mass Spectrom       Date:  2007-10-30       Impact factor: 3.109

5.  Parts-per-billion mass measurement accuracy achieved through the combination of multiple linear regression and automatic gain control in a Fourier transform ion cyclotron resonance mass spectrometer.

Authors:  D Keith Williams; David C Muddiman
Journal:  Anal Chem       Date:  2007-06-01       Impact factor: 6.986

6.  Data Self-Recalibration and Mixture Mass Fingerprint Searching (DASER-MMF) to enhance protein identification within complex mixtures.

Authors:  Ryan M Danell; Severine A Ouvry-Patat; Cameron O Scarlett; J Paul Speir; Christoph H Borchers
Journal:  J Am Soc Mass Spectrom       Date:  2008-07-20       Impact factor: 3.109

7.  Unit mass baseline resolution for an intact 148 kDa therapeutic monoclonal antibody by Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Santosh G Valeja; Nathan K Kaiser; Feng Xian; Christopher L Hendrickson; Jason C Rouse; Alan G Marshall
Journal:  Anal Chem       Date:  2011-10-20       Impact factor: 6.986

8.  Experimental Evidence for Space-Charge Effects between Ions of the Same Mass-to-Charge in Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry.

Authors:  Richard L Wong; I Jonathan Amster
Journal:  Int J Mass Spectrom       Date:  2007-09-01       Impact factor: 1.986

Review 9.  Approaches for the study of cancer: towards the integration of genomics, proteomics and metabolomics.

Authors:  Juan Casado-Vela; Arancha Cebrián; María Teresa Gómez del Pulgar; Juan Carlos Lacal
Journal:  Clin Transl Oncol       Date:  2011-09       Impact factor: 3.405

10.  Mass recalibration of FT-ICR mass spectrometry imaging data using the average frequency shift of ambient ions.

Authors:  Jeremy A Barry; Guillaume Robichaud; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2013-05-29       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.