Literature DB >> 18061475

Improved mass accuracy for higher mass peptides by using SWIFT excitation for MALDI-FTICR mass spectrometry.

Li Jing1, Chunyan Li, Richard L Wong, Desmond A Kaplan, I Jonathan Amster.   

Abstract

Stepwise-external calibration has previously been shown to produce sub part-per-million (ppm) mass accuracy for the MALDI-FTICR/MS analyses of peptides up to m/z 2500. The present work extends these results to ions up to m/z 4000. Mass measurement errors for ions of higher mass-to-charge are larger than for ions below m/z 2500 when using conventional chirp excitation to detect ions. Mass accuracy obtained by using stored waveform inverse Fourier transform (SWIFT) excitation was evaluated and compared with chirp excitation. Analysis of measurement errors reveals that SWIFT excitation provides smaller deviations from the calibration equation and better mass accuracy than chirp excitation for a wide mass range and for widely varying ion populations.

Mesh:

Substances:

Year:  2007        PMID: 18061475      PMCID: PMC2242857          DOI: 10.1016/j.jasms.2007.10.013

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  20 in total

1.  Broad-band ion accumulation with an internal source MALDI-FTICR-MS.

Authors:  T H Mize; I J Amster
Journal:  Anal Chem       Date:  2000-12-15       Impact factor: 6.986

2.  Internal calibration on adjacent samples (InCAS) with Fourier transform mass spectrometry.

Authors:  P B O'Connor; C E Costello
Journal:  Anal Chem       Date:  2000-12-15       Impact factor: 6.986

3.  Baseline mass resolution of peptide isobars: a record for molecular mass resolution.

Authors:  F He; C L Hendrickson; A G Marshall
Journal:  Anal Chem       Date:  2001-02-01       Impact factor: 6.986

4.  Utility of accurate mass tags for proteome-wide protein identification.

Authors:  T P Conrads; G A Anderson; T D Veenstra; L Pasa-Tolić; R D Smith
Journal:  Anal Chem       Date:  2000-07-15       Impact factor: 6.986

5.  Using accurate mass electrospray ionization-time-of-flight mass spectrometry with in-source collision-induced dissociation to sequence peptide mixtures.

Authors:  Jon D Williams; Michael Flanagan; Linda Lopez; Steve Fischer; Luke A D Miller
Journal:  J Chromatogr A       Date:  2003-12-05       Impact factor: 4.759

6.  Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications.

Authors:  John E P Syka; Jarrod A Marto; Dina L Bai; Stevan Horning; Michael W Senko; Jae C Schwartz; Beatrix Ueberheide; Benjamin Garcia; Scott Busby; Tara Muratore; Jeffrey Shabanowitz; Donald F Hunt
Journal:  J Proteome Res       Date:  2004 May-Jun       Impact factor: 4.466

7.  Sub part-per-million mass accuracy by using stepwise-external calibration in fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Richard L Wong; I Jonathan Amster
Journal:  J Am Soc Mass Spectrom       Date:  2006-08-24       Impact factor: 3.109

8.  Parts-per-billion mass measurement accuracy achieved through the combination of multiple linear regression and automatic gain control in a Fourier transform ion cyclotron resonance mass spectrometer.

Authors:  D Keith Williams; David C Muddiman
Journal:  Anal Chem       Date:  2007-06-01       Impact factor: 6.986

9.  Statistical evaluation of internal and external mass calibration laws utilized in fourier transform ion cyclotron resonance mass spectrometry.

Authors:  David C Muddiman; Ann L Oberg
Journal:  Anal Chem       Date:  2005-04-15       Impact factor: 6.986

10.  Investigation into accurate mass capability of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, with respect to radical ion species.

Authors:  Mark F Wyatt; Bridget K Stein; A Gareth Brenton
Journal:  J Am Soc Mass Spectrom       Date:  2006-03-15       Impact factor: 3.109

View more
  2 in total

1.  Challenges and opportunities for on-line monitoring of chlorine-produced oxidants in seawater using portable membrane-introduction Fourier transform-ion cyclotron resonance mass spectrometry.

Authors:  Adrien Roumiguières; Stéphane Bouchonnet; Said Kinani
Journal:  Anal Bioanal Chem       Date:  2020-11-19       Impact factor: 4.142

2.  An improved calibration method for the matrix-assisted laser desorption/ionization-Fourier transform ion cyclotron resononance analysis of 15N-metabolically- labeled proteome digests using a mass difference approach.

Authors:  Li Jing; I Jonathan Amster
Journal:  Eur J Mass Spectrom (Chichester)       Date:  2012       Impact factor: 1.067

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.