Literature DB >> 21953187

Trapping radial electric field optimization in compensated FTICR cells.

Aleksey V Tolmachev1, Errol W Robinson, Si Wu, Richard D Smith, Ljiljana Paša-Toli.   

Abstract

Herein, we present the theoretical and experimental study of the recently introduced FTICR cell designs. We developed an approach that determines the electric field inside the cell, based on the measurement of calibration coefficients as a function of post-excitation radius and other conditions. Using the radial electric field divided by radius (E(r)/r) as a criterion of the cell harmonization, we compare the compensated cell approach with alternative designs and discuss practical implications of the cell compensation.

Mesh:

Year:  2011        PMID: 21953187     DOI: 10.1007/s13361-011-0167-z

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  15 in total

1.  Charge capacity limitations of radio frequency ion guides in their use for improved ion accumulation and trapping in mass spectrometry.

Authors:  A V Tolmachev; H R Udseth; R D Smith
Journal:  Anal Chem       Date:  2000-03-01       Impact factor: 6.986

2.  Mass measurement errors caused by 'local" frequency perturbations in FTICR mass spectrometry.

Authors:  Christophe Masselon; Aleksey V Tolmachev; Gordon A Anderson; Richard Harkewicz; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2002-01       Impact factor: 3.109

3.  Fourier transform ion cyclotron resonance mass spectrometer with coaxial multi-electrode cell ('O-trap'): first experimental demonstration.

Authors:  A S Misharin; R A Zubarev; V M Doroshenko
Journal:  Rapid Commun Mass Spectrom       Date:  2010-07-30       Impact factor: 2.419

4.  Fourier transform ion cyclotron resonance cell with dynamic harmonization of the electric field in the whole volume by shaping of the excitation and detection electrode assembly.

Authors:  Ivan A Boldin; Eugene N Nikolaev
Journal:  Rapid Commun Mass Spectrom       Date:  2011-01-15       Impact factor: 2.419

5.  Sub part-per-million mass accuracy by using stepwise-external calibration in fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Richard L Wong; I Jonathan Amster
Journal:  J Am Soc Mass Spectrom       Date:  2006-08-24       Impact factor: 3.109

6.  Understanding the influence of post-excite radius and axial confinement on quantitative proteomic measurements using Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Jennifer L Frahm; Coral M Capo Velez; David C Muddiman
Journal:  Rapid Commun Mass Spectrom       Date:  2007       Impact factor: 2.419

7.  Parts-per-billion mass measurement accuracy achieved through the combination of multiple linear regression and automatic gain control in a Fourier transform ion cyclotron resonance mass spectrometer.

Authors:  D Keith Williams; David C Muddiman
Journal:  Anal Chem       Date:  2007-06-01       Impact factor: 6.986

8.  Targeted tandem mass spectrometry for high-throughput comparative proteomics employing NanoLC-FTICR MS with external ion dissociation.

Authors:  Hyuk Kang; Ljiljana Pasa-Tolić; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2007-05-03       Impact factor: 3.109

9.  Space charge effects in Fourier transform mass spectrometry. Mass calibration.

Authors:  E B Ledford; D L Rempel; M L Gross
Journal:  Anal Chem       Date:  1984-12       Impact factor: 6.986

10.  An electrically compensated trap designed to eighth order for FT-ICR mass spectrometry.

Authors:  Adam M Brustkern; Don L Rempel; Michael L Gross
Journal:  J Am Soc Mass Spectrom       Date:  2008-07-02       Impact factor: 3.109

View more
  5 in total

1.  Angular averaged profiling of the radial electric field in compensated FTICR Cells.

Authors:  Aleksey V Tolmachev; Errol W Robinson; Si Wu; Richard D Smith; Jean H Futrell; Ljiljana Paša-Tolić
Journal:  J Am Soc Mass Spectrom       Date:  2012-05-08       Impact factor: 3.109

2.  Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency.

Authors:  Konstantin O Nagornov; Anton N Kozhinov; Yury O Tsybin
Journal:  J Am Soc Mass Spectrom       Date:  2017-02-17       Impact factor: 3.109

3.  Autophaser: an algorithm for automated generation of absorption mode spectra for FT-ICR MS.

Authors:  David P A Kilgour; Rebecca Wills; Yulin Qi; Peter B O'Connor
Journal:  Anal Chem       Date:  2013-03-26       Impact factor: 6.986

4.  Characterization of ion dynamics in structures for lossless ion manipulations.

Authors:  Aleksey V Tolmachev; Ian K Webb; Yehia M Ibrahim; Sandilya V B Garimella; Xinyu Zhang; Gordon A Anderson; Richard D Smith
Journal:  Anal Chem       Date:  2014-09-04       Impact factor: 6.986

5.  Classification of the Biogenicity of Complex Organic Mixtures for the Detection of Extraterrestrial Life.

Authors:  Nicholas Guttenberg; Huan Chen; Tomohiro Mochizuki; H James Cleaves
Journal:  Life (Basel)       Date:  2021-03-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.