Literature DB >> 15792715

Improved mass accuracy for tandem mass spectrometry.

Nathan K Kaiser1, Gordon A Anderson, James E Bruce.   

Abstract

With the emergence of top-down proteomics, the ability to achieve high mass measurement accuracy on tandem MS/MS data will be beneficial for protein identification and characterization. (FT-ICR) Fourier transform ion cyclotron resonance mass spectrometers are the ideal instruments to perform these experiments with their ability to provide high resolution and mass accuracy. A major limitation to mass measurement accuracy in FT-ICR instruments arises from the occurrence of space charge effects. These space charge effects shift the cyclotron frequency of the ions, which compromises the mass measurement accuracy. While several methods have been developed that correct these space charge effects, they have limitations when applied to MS/MS experiments. It has already been shown that additional information inherent in electrospray spectra can be used for improved mass measurement accuracy with the use of a computer algorithm called DeCAL (deconvolution of Coulombic affected linearity). This paper highlights a new application of the strategy for improved mass accuracy in tandem mass analysis. The results show a significant improvement in mass measurement accuracy on complex electron capture dissociation spectra of proteins. We also demonstrate how the improvement in mass accuracy can increase the confidence in protein identification from the fragment masses of proteins acquired in MS/MS experiments.

Mesh:

Substances:

Year:  2005        PMID: 15792715     DOI: 10.1016/j.jasms.2004.12.005

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  26 in total

1.  Accurate mass multiplexed tandem mass spectrometry for high-throughput polypeptide identification from mixtures.

Authors:  C Masselon; G A Anderson; R Harkewicz; J E Bruce; L Pasa-Tolic; R D Smith
Journal:  Anal Chem       Date:  2000-04-15       Impact factor: 6.986

2.  Role of accurate mass measurement (+/- 10 ppm) in protein identification strategies employing MS or MS/MS and database searching.

Authors:  K R Clauser; P Baker; A L Burlingame
Journal:  Anal Chem       Date:  1999-07-15       Impact factor: 6.986

3.  Top-down mass spectrometry of a 29-kDa protein for characterization of any posttranslational modification to within one residue.

Authors:  Siu Kwan Sze; Ying Ge; HanBin Oh; Fred W McLafferty
Journal:  Proc Natl Acad Sci U S A       Date:  2002-02-12       Impact factor: 11.205

4.  Informatics and multiplexing of intact protein identification in bacteria and the archaea.

Authors:  F Meng; B J Cargile; L M Miller; A J Forbes; J R Johnson; N L Kelleher
Journal:  Nat Biotechnol       Date:  2001-10       Impact factor: 54.908

5.  Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry.

Authors:  John E P Syka; Joshua J Coon; Melanie J Schroeder; Jeffrey Shabanowitz; Donald F Hunt
Journal:  Proc Natl Acad Sci U S A       Date:  2004-06-21       Impact factor: 11.205

Review 6.  Fourier transform ion cyclotron resonance mass spectrometry: a primer.

Authors:  A G Marshall; C L Hendrickson; G S Jackson
Journal:  Mass Spectrom Rev       Date:  1998 Jan-Feb       Impact factor: 10.946

7.  Accurate mass measurements using MALDI-TOF with delayed extraction.

Authors:  E J Takach; W M Hines; D H Patterson; P Juhasz; A M Falick; M L Vestal; S A Martin
Journal:  J Protein Chem       Date:  1997-07

8.  Localization of O-glycosylation sites in peptides by electron capture dissociation in a Fourier transform mass spectrometer.

Authors:  E Mirgorodskaya; P Roepstorff; R A Zubarev
Journal:  Anal Chem       Date:  1999-10-15       Impact factor: 6.986

9.  Space charge effects in Fourier transform mass spectrometry. Mass calibration.

Authors:  E B Ledford; D L Rempel; M L Gross
Journal:  Anal Chem       Date:  1984-12       Impact factor: 6.986

10.  Electron capture dissociation and infrared multiphoton dissociation MS/MS of an N-glycosylated tryptic peptic to yield complementary sequence information.

Authors:  K Håkansson; H J Cooper; M R Emmett; C E Costello; A G Marshall; C L Nilsson
Journal:  Anal Chem       Date:  2001-09-15       Impact factor: 6.986

View more
  7 in total

1.  Sub parts-per-million mass measurement accuracy of intact proteins and product ions achieved using a dual electrospray ionization quadrupole fourier transform ion cyclotron resonance mass spectrometer.

Authors:  D Keith Williams; Adam M Hawkridge; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2006-09-18       Impact factor: 3.109

Review 2.  Modern instrumental methods in forensic toxicology.

Authors:  Michael L Smith; Shawn P Vorce; Justin M Holler; Eric Shimomura; Joe Magluilo; Aaron J Jacobs; Marilyn A Huestis
Journal:  J Anal Toxicol       Date:  2007-06       Impact factor: 3.367

3.  Parts-per-billion mass measurement accuracy achieved through the combination of multiple linear regression and automatic gain control in a Fourier transform ion cyclotron resonance mass spectrometer.

Authors:  D Keith Williams; David C Muddiman
Journal:  Anal Chem       Date:  2007-06-01       Impact factor: 6.986

4.  Data Self-Recalibration and Mixture Mass Fingerprint Searching (DASER-MMF) to enhance protein identification within complex mixtures.

Authors:  Ryan M Danell; Severine A Ouvry-Patat; Cameron O Scarlett; J Paul Speir; Christoph H Borchers
Journal:  J Am Soc Mass Spectrom       Date:  2008-07-20       Impact factor: 3.109

5.  De novo correction of mass measurement error in low resolution tandem MS spectra for shotgun proteomics.

Authors:  Jarrett D Egertson; Jimmy K Eng; Michael S Bereman; Edward J Hsieh; Gennifer E Merrihew; Michael J MacCoss
Journal:  J Am Soc Mass Spectrom       Date:  2012-09-25       Impact factor: 3.109

6.  Utilizing artificial neural networks in MATLAB to achieve parts-per-billion mass measurement accuracy with a fourier transform ion cyclotron resonance mass spectrometer.

Authors:  D Keith Williams; Alexander L Kovach; David C Muddiman; Kenneth W Hanck
Journal:  J Am Soc Mass Spectrom       Date:  2009-03-11       Impact factor: 3.109

7.  multiplierz: an extensible API based desktop environment for proteomics data analysis.

Authors:  Jignesh R Parikh; Manor Askenazi; Scott B Ficarro; Tanya Cashorali; James T Webber; Nathaniel C Blank; Yi Zhang; Jarrod A Marto
Journal:  BMC Bioinformatics       Date:  2009-10-29       Impact factor: 3.169

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.