Literature DB >> 11305659

High-mass accuracy of product ions produced by SORI-CID using a dual electrospray ionization source coupled with FTICR mass spectrometry.

J W Flora1, J C Hannis, D C Muddiman.   

Abstract

High-mass accuracy is demonstrated using internal calibration for product ions produced by sustained off-resonance irradiation collision-induced dissociation (SORI-CID) of a 15-mer oligonucleotide, 5'-(CTG)5-3'. Internal calibration for this tandem MS experiment was accomplished using a dual electrospray ionization (ESI) source coupled with Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) utilizing hexapole accumulation and gated trapping. The pulse sequence entails injection, trapping, and gas-phase isolation of the precursor ion of interest followed by the SORI-CID of this ion and, subsequently, injection and trapping of the internal mass calibrant (i.e., poly(ethylene glycol) with a 1000 Da average mass). The product ions and the poly(ethylene glycol) ions are then simultaneously excited by a broadband frequency chirp excitation waveform and detected. This technique corrects for space-charge effects on the measurement of an ion's cyclotron frequency experienced when externally calibrated data are used. While external calibration for FTICR-MS can result in mass errors of greater than 100 ppm, this internal standardization method demonstrated significantly more consistent accurate mass measurements with average mass errors ranging from -1.2 to -3.2 ppm for the 15-mer oligonucleotide used in this study. This method requires limited modifications to ESI-FTICR mass spectrometers and is applicable for both positive and negative modes of ionization as well as other sample types (e.g., pharmaceuticals, proteins, etc.).

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11305659     DOI: 10.1021/ac0011282

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  17 in total

1.  A general method for precalculation of parameters for sustained off resonance irradiation/collision-induced dissociation.

Authors:  Ekaterina Mirgorodskaya; Peter B O'Connor; Catherine E Costello
Journal:  J Am Soc Mass Spectrom       Date:  2002-04       Impact factor: 3.109

2.  Solution composition and thermal denaturation for the production of single-stranded PCR amplicons: piperidine-induced destabilization of the DNA duplex?

Authors:  John B Mangrum; Jason W Flora; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2002-03       Impact factor: 3.109

3.  Use of the filter diagonalization method in the study of space charge related frequency modulation in fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Konstantin Aizikov; Peter B O'Connor
Journal:  J Am Soc Mass Spectrom       Date:  2006-04-17       Impact factor: 3.109

Review 4.  Advances in proteomics data analysis and display using an accurate mass and time tag approach.

Authors:  Jennifer S D Zimmer; Matthew E Monroe; Wei-Jun Qian; Richard D Smith
Journal:  Mass Spectrom Rev       Date:  2006 May-Jun       Impact factor: 10.946

5.  Sub parts-per-million mass measurement accuracy of intact proteins and product ions achieved using a dual electrospray ionization quadrupole fourier transform ion cyclotron resonance mass spectrometer.

Authors:  D Keith Williams; Adam M Hawkridge; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2006-09-18       Impact factor: 3.109

6.  Parts-per-billion mass measurement accuracy achieved through the combination of multiple linear regression and automatic gain control in a Fourier transform ion cyclotron resonance mass spectrometer.

Authors:  D Keith Williams; David C Muddiman
Journal:  Anal Chem       Date:  2007-06-01       Impact factor: 6.986

Review 7.  Accurate mass measurements in proteomics.

Authors:  Tao Liu; Mikhail E Belov; Navdeep Jaitly; Wei-Jun Qian; Richard D Smith
Journal:  Chem Rev       Date:  2007-07-25       Impact factor: 60.622

8.  Dual electrospray ion source for electron-transfer dissociation on a hybrid linear ion trap-orbitrap mass spectrometer.

Authors:  D Keith Williams; Graeme C McAlister; David M Good; Joshua J Coon; David C Muddiman
Journal:  Anal Chem       Date:  2007-09-15       Impact factor: 6.986

9.  Mass recalibration of FT-ICR mass spectrometry imaging data using the average frequency shift of ambient ions.

Authors:  Jeremy A Barry; Guillaume Robichaud; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2013-05-29       Impact factor: 3.109

10.  Advantages of Thermococcus kodakaraenis (KOD) DNA Polymerase for PCR-mass spectrometry based analyses.

Authors:  Linda M Benson; Allison P Null; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2003-06       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.