Literature DB >> 15739550

Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysms.

Pedro Lylyk1, Angel Ferrario, Boris Pasbón, Carlos Miranda, Gustavo Doroszuk.   

Abstract

OBJECT: The authors report their experience with the use of the Neuroform Microdelivery System for intravascular reconstruction. They assess the technical feasibility of the system, the efficacy of the combined application of stent and detachable coils, and the follow-up findings.
METHODS: Fifty patients found to harbor a complex wide-necked intracranial aneurysm were selected for the study. Different strategies were chosen and the performance and technical success of the device were evaluated. Stent placement was recorded as optimal or suboptimal with respect to the stent position. Clinical and angiographic follow-up examinations were obtained. Forty-six patients with 48 intracranial aneurysms were treated, leading to a technical success rate of 92%. Forty-two lesions were located in the anterior circulation. In every case the dome/neck ratio was less than 2 and the mean aneurysm size in these patients was 8.8 mm. The most frequent clinical presentation was subarachnoid hemorrhage in 48% of cases. Stent placement was optimal in 81.2% of cases and suboptimal in 18.8%. In 31% of cases, the investigators encountered difficulties in placing the Neuroform stent. Clinical follow up was recorded in all patients and angiographic follow up was obtained in 63%. There were no cases of repeated hemorrhage. In a single case in which only the stent was implanted progressive thrombosis was identified during the follow-up period. The procedure-related morbidity and mortality rates were 8.6 and 2.1%, respectively.
CONCLUSIONS: On the basis of the results, the authors conclude that the Neuroform self-expanding stent is a flexible and useful device that can be readily and safely maneuvered through tortuous intracranial vessels, enabling the endovascular treatment of complex wide-necked aneurysms. Early in the authors' experience, stent delivery presented difficulties; however, a second generation of devices has resolved this limitation. Although the early results are promising, the long-term benefit of this technique has to be proved by angiographic and clinical follow-up examinations.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15739550     DOI: 10.3171/jns.2005.102.2.0235

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  59 in total

1.  Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment.

Authors:  J R Cebral; F Mut; M Raschi; E Scrivano; R Ceratto; P Lylyk; C M Putman
Journal:  AJNR Am J Neuroradiol       Date:  2010-11-11       Impact factor: 3.825

2.  Ten-year follow-up of giant basilar aneurysm treated by sole stenting technique: a case report.

Authors:  Marco Zenteno; Camilo R Gómez; Ja Santos-Franco; Fernando Vinuela; Y Aburto-Murrieta; Angel Lee
Journal:  J Med Case Rep       Date:  2010-02-22

3.  A novel self-expanding fully retrievable intracranial stent (SOLO): experience in nine procedures of stent-assisted aneurysm coil occlusion.

Authors:  Thomas Liebig; Hans Henkes; Jörg Reinartz; Elina Miloslavski; Dietmar Kühne
Journal:  Neuroradiology       Date:  2006-06-07       Impact factor: 2.804

4.  Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study.

Authors:  N Ebrahimi; B Claus; C-Y Lee; A Biondi; G Benndorf
Journal:  AJNR Am J Neuroradiol       Date:  2007-05       Impact factor: 3.825

5.  Current status and future prospect of endovascular neurosurgery.

Authors:  Young Il Jeon; Do Hoon Kwon
Journal:  J Korean Neurosurg Soc       Date:  2008-02-20

Review 6.  Materials and techniques for coiling of cerebral aneurysms: how much scientific evidence do we have?

Authors:  W Kurre; J Berkefeld
Journal:  Neuroradiology       Date:  2008-09-19       Impact factor: 2.804

7.  Identification of crucial genes in intracranial aneurysm based on weighted gene coexpression network analysis.

Authors:  X Zheng; C Xue; G Luo; Y Hu; W Luo; X Sun
Journal:  Cancer Gene Ther       Date:  2015-02-27       Impact factor: 5.987

8.  Embolization of acutely ruptured and unruptured wide-necked cerebral aneurysms using the neuroform2 stent without pretreatment with antiplatelets: a single center experience.

Authors:  V Katsaridis; C Papagiannaki; C Violaris
Journal:  AJNR Am J Neuroradiol       Date:  2006-05       Impact factor: 3.825

9.  Influence of clinical and anatomic features on treatment decisions for anterior communicating artery aneurysms.

Authors:  Jae-Hyung Choi; Myung-Jin Kang; Jae-Taeck Huh
Journal:  J Korean Neurosurg Soc       Date:  2011-08-31

10.  Effect of endovascular treatment on headache in elderly patients with unruptured intracranial aneurysms.

Authors:  D-Q Gu; C-Z Duan; X-F Li; X-Y He; L-F Lai; S-X Su
Journal:  AJNR Am J Neuroradiol       Date:  2012-12-06       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.