Literature DB >> 26275447

Simultaneous reconstruction of attenuation and activity in cardiac PET can remove CT misalignment artifacts.

L Presotto1,2, E Busnardo3, D Perani4,5,3, L Gianolli3, M C Gilardi6, V Bettinardi3.   

Abstract

BACKGROUND: Misalignment between positron emission tomography (PET) and computed tomography (CT) data is known to generate artifactual defects in cardiac PET images due to imprecise attenuation correction (AC). In this work, the use of a maximum likelihood attenuation and activity (MLAA) algorithm is proposed to avoid such artifacts in time-of-flight (TOF) PET.
METHODS: MLAA was implemented and tested using a thorax/heart phantom and retrospectively on fourteen (13)N-ammonia PET/CT perfusion studies. Global and local misalignments between PET and CT data were generated by shifting matched CT images or using CT data representative of the end-inspiration phase. PET images were reconstructed with MLAA and a 3D-ordered-subsets-expectation-maximization (OSEM)-TOF algorithm. Images obtained with 3D-OSEM-TOF and matched CT were used as references. These images were compared (qualitatively and semi-quantitatively) with those reconstructed with 3D-OSEM-TOF and MLAA for which a misaligned CT was used, respectively, for AC and initialization.
RESULTS: Phantom experiment proved the capability of MLAA to converge toward the correct emission and attenuation distributions using, as input, only PET emission data, but convergence was very slow. Initializing MLAA with phantom CT images markedly improved convergence speed. In patient studies, when shifted or end-inspiration CT images were used for AC, 3D-OSEM-TOF reconstructions showed artifacts of increasing severity, size, and frequency with increasing mismatch. Such artifacts were absent in the corresponding MLAA images.
CONCLUSION: The proposed implementation of the MLAA algorithm is a feasible and robust technique to avoid AC mismatch artifacts in cardiac PET studies provided that a CT of the source is available, even if poorly aligned.

Entities:  

Keywords:  Image artifacts; PET imaging; attenuation and scatter correction; image reconstruction; myocardial perfusion imaging: PET

Mesh:

Year:  2015        PMID: 26275447     DOI: 10.1007/s12350-015-0239-8

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  25 in total

1.  Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms.

Authors:  J Nuyts; P Dupont; S Stroobants; R Benninck; L Mortelmans; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1999-05       Impact factor: 10.048

Review 2.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Warren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Circulation       Date:  2002-01-29       Impact factor: 29.690

3.  Simultaneous reconstruction of activity and attenuation in time-of-flight PET.

Authors:  Ahmadreza Rezaei; Michel Defrise; Girish Bal; Christian Michel; Maurizio Conti; Charles Watson; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2012-08-09       Impact factor: 10.048

4.  Interpolated average CT for cardiac PET/CT attenuation correction.

Authors:  Greta S P Mok; Cobie Y T Ho; Bang-Hung Yang; Tung-Hsin Wu
Journal:  J Nucl Cardiol       Date:  2015-05-02       Impact factor: 5.952

5.  Automatic registration of misaligned CT attenuation correction maps in Rb-82 PET/CT improves detection of angiographically significant coronary artery disease.

Authors:  Piotr J Slomka; Mariana Diaz-Zamudio; Damini Dey; Manish Motwani; Yafim Brodov; David Choi; Sean Hayes; Louise Thomson; John Friedman; Guido Germano; Daniel Berman
Journal:  J Nucl Cardiol       Date:  2015-02-20       Impact factor: 5.952

6.  Motion-Tracking Hardware and Advanced Applications in PET and PET/CT.

Authors:  V Bettinardi; E De Bernardi; L Presotto; M C Gilardi
Journal:  PET Clin       Date:  2012-11-26

7.  Respiratory phase alignment improves blood-flow quantification in Rb82 PET myocardial perfusion imaging.

Authors:  Amir Pourmoghaddas; Ran Klein; Robert A deKemp; R Glenn Wells
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

8.  Cine CT for attenuation correction in cardiac PET/CT.

Authors:  Adam M Alessio; Steve Kohlmyer; Kelley Branch; Grace Chen; James Caldwell; Paul Kinahan
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

9.  Minimizing artifacts resulting from respiratory and cardiac motion by optimization of the transmission scan in cardiac PET/CT.

Authors:  Jonathon A Nye; Fabio Esteves; John R Votaw
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

Review 10.  Cardiac hybrid imaging: state-of-the-art.

Authors:  Philipp A Kaufmann
Journal:  Ann Nucl Med       Date:  2009-04-10       Impact factor: 2.668

View more
  7 in total

1.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  Advances in imaging instrumentation for nuclear cardiology.

Authors:  Jae Sung Lee; Gil Kovalski; Tali Sharir; Dong Soo Lee
Journal:  J Nucl Cardiol       Date:  2017-07-17       Impact factor: 5.952

3.  Time-of-flight in cardiac PET/TC: What do we know and what we should know?

Authors:  Roberta Matheoud; Michela Lecchi
Journal:  J Nucl Cardiol       Date:  2018-06-21       Impact factor: 5.952

Review 4.  Updates on Stress Imaging Testing and Myocardial Viability With Advanced Imaging Modalities.

Authors:  Sandeep S Hedgire; Michael Osborne; Daniel J Verdini; Brian B Ghoshhajra
Journal:  Curr Treat Options Cardiovasc Med       Date:  2017-04

5.  The dream of imaging coronary artery inflammation with FDG PET/CT imaging.

Authors:  R Glenn Wells; Terrence D Ruddy
Journal:  J Nucl Cardiol       Date:  2016-06-03       Impact factor: 5.952

6.  Joint Reconstruction of Activity and Attenuation in Time-of-Flight PET: A Quantitative Analysis.

Authors:  Ahmadreza Rezaei; Christophe M Deroose; Thomas Vahle; Fernando Boada; Johan Nuyts
Journal:  J Nucl Med       Date:  2018-03-01       Impact factor: 10.057

7.  PET-enabled dual-energy CT: image reconstruction and a proof-of-concept computer simulation study.

Authors:  Guobao Wang
Journal:  Phys Med Biol       Date:  2020-12-17       Impact factor: 3.609

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.