BACKGROUND: Previously, we proposed interpolated averaged CT (IACT) for improved attenuation correction (AC) in thoracic PET/CT. This study aims to evaluate its feasibility and effectiveness on cardiac PET/CT.
METHODS: We simulated (18)F-FDG distribution using the XCAT phantom with normal and abnormal cardiac uptake. Average activity and attenuation maps represented static PET and respiration average CT (ACT), respectively, while the attenuation maps of end-inspiration/expiration represented 2 helical CTs (HCT). IACT was obtained by averaging the 2 extreme phases and the interpolated phases generated between them. Later, we recruited 4 patients who were scanned 1 hr post 315-428 MBq (18)F-FDG injection. Simulated and clinical PET sinograms were reconstructed with AC using (1) HCT, (2) IACT, and (3) ACT. Polar plots and the 17-segment plots were analyzed. Two regions-of-interest were drawn on lesion and background area to obtain the intensity ratio (IR).
RESULTS: Polar plots of PETIACT-AC were more similar to PETACT-AC in both simulation and clinical data. Artifacts were observed in various segments in PETHCT-AC. IR differences of HCT as compared to the phantom were up to ~20%.
CONCLUSIONS: IACT-AC reduced respiratory artifacts and improved PET/CT matching similarly to ACT-AC. It is a promising low-dose alternate of ACT for cardiac PET/CT.

Entities:  

Keywords:  PET/CT; attenuation correction; cardiac imaging; respiratory artifacts

Mesh:

Year:  2015        PMID: 25933679     DOI: 10.1007/s12350-015-0140-5

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  30 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Warren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  J Nucl Cardiol       Date:  2002 Mar-Apr       Impact factor: 5.952

2.  Attenuation correction of PET images with respiration-averaged CT images in PET/CT.

Authors:  Tinsu Pan; Osama Mawlawi; Sadek A Nehmeh; Yusuf E Erdi; Dershan Luo; Hui H Liu; Richard Castillo; Radhe Mohan; Zhongxing Liao; H A Macapinlac
Journal:  J Nucl Med       Date:  2005-09       Impact factor: 10.057

3.  Artifacts from misaligned CT in cardiac perfusion PET/CT studies: frequency, effects, and potential solutions.

Authors:  Axel Martinez-Möller; Michael Souvatzoglou; Nassir Navab; Markus Schwaiger; Stephan G Nekolla
Journal:  J Nucl Med       Date:  2007-02       Impact factor: 10.057

4.  Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT.

Authors:  Sarah J McQuaid; Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-01-25       Impact factor: 9.236

5.  Techniques for respiration-induced artifacts reductions in thoracic PET/CT.

Authors:  Tao Sun; Greta S P Mok
Journal:  Quant Imaging Med Surg       Date:  2012-03

6.  Attenuation correction of PET cardiac data with low-dose average CT in PET/CT.

Authors:  Tinsu Pan; Osama Mawlawi; Dershan Luo; Hui H Liu; Pai-Chun M Chi; Martha V Mar; Gregory Gladish; Mylene Truong; Jeremy Erasmus; Zhongxing Liao; H A Macapinlac
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

7.  Cine CT for attenuation correction in cardiac PET/CT.

Authors:  Adam M Alessio; Steve Kohlmyer; Kelley Branch; Grace Chen; James Caldwell; Paul Kinahan
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

8.  Respiration-averaged CT for attenuation correction in canine cardiac PET/CT.

Authors:  Russell A H Cook; Greg Carnes; Ting-Yim Lee; R Glenn Wells
Journal:  J Nucl Med       Date:  2007-04-27       Impact factor: 10.057

9.  Interpolated average CT for attenuation correction in PET--a simulation study.

Authors:  Greta S P Mok; Tao Sun; Tzung-Chi Huang; Mang I Vai
Journal:  IEEE Trans Biomed Eng       Date:  2013-02-06       Impact factor: 4.538

10.  Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT.

Authors:  Timothy M Bateman; Gary V Heller; A Iain McGhie; John D Friedman; James A Case; Jan R Bryngelson; Ginger K Hertenstein; Kelly L Moutray; Kimberly Reid; S James Cullom
Journal:  J Nucl Cardiol       Date:  2006 Jan-Feb       Impact factor: 5.952

View more
  3 in total

1.  Simultaneous reconstruction of attenuation and activity in cardiac PET can remove CT misalignment artifacts.

Authors:  L Presotto; E Busnardo; D Perani; L Gianolli; M C Gilardi; V Bettinardi
Journal:  J Nucl Cardiol       Date:  2015-08-15       Impact factor: 5.952

2.  Hybrid PET- and MR-driven attenuation correction for enhanced 18F-NaF and 18F-FDG quantification in cardiovascular PET/MR imaging.

Authors:  Nicolas A Karakatsanis; Ronan Abgral; Maria Giovanna Trivieri; Marc R Dweck; Philip M Robson; Claudia Calcagno; Gilles Boeykens; Max L Senders; Willem J M Mulder; Charalampos Tsoumpas; Zahi A Fayad
Journal:  J Nucl Cardiol       Date:  2019-10-30       Impact factor: 5.952

Review 3.  Pitfalls on PET/CT Due to Artifacts and Instrumentation.

Authors:  Yu-Jung Tsai; Chi Liu
Journal:  Semin Nucl Med       Date:  2021-07-07       Impact factor: 4.446

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.