Literature DB >> 17463114

Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study.

Y-H Kim1, J-S Kim, S-H Yoon.   

Abstract

Bilateral sequential total knee replacement was carried out under one anaesthetic in 100 patients. One knee was replaced using a CT-free computer-assisted navigation system and the other conventionally without navigation. The two methods were compared for accuracy of orientation and alignment of the components. There were 85 women and 15 men with a mean age of 67.6 years (54 to 83). Radiological and CT imaging was carried out to determine the alignment of the components. The mean follow-up was 2.3 years (2 to 3). The operating and tourniquet times were significantly longer in the navigation group (p < 0.001). There were no significant pre- or post-operative differences between the knee scores of the two groups (p = 0.288 and p = 0.429, respectively). The results of imaging and the number of outliers for all radiological parameters were not statistically different (p = 0.109 to p = 0.920). In this series computer-assisted navigated total knee replacement did not result in more accurate orientation and alignment of the components than that achieved by conventional total knee replacement.

Entities:  

Mesh:

Year:  2007        PMID: 17463114     DOI: 10.1302/0301-620X.89B4.18878

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  52 in total

1.  No influence of femoral component rotation by the lateral femoral posterior condylar cartilage remnant technique on clinical outcomes in navigation-assisted TKA.

Authors:  Seong Hwan Kim; Yong-Beom Park; Dae Woong Ham; Jae-Sung Lee; Min-Ku Song; Han-Jun Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-08-02       Impact factor: 4.342

2.  Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies.

Authors:  Yaron S Brin; Vassilios S Nikolaou; Lawrence Joseph; David J Zukor; John Antoniou
Journal:  Int Orthop       Date:  2010-04-08       Impact factor: 3.075

3.  Femur bowing could be a risk factor for implant flexion in conventional total knee arthroplasty and notching in navigated total knee arthroplasty.

Authors:  Jae Han Ko; Chang Dong Han; Kyoo Ho Shin; Levis Nguku; Ick Hwan Yang; Woo Suk Lee; Kwang Il Kim; Kwan Kyu Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-18       Impact factor: 4.342

4.  Computer navigation did not improve alignment in a lower-volume total knee practice.

Authors:  W P Yau; K Y Chiu; J L Zuo; W M Tang; T P Ng
Journal:  Clin Orthop Relat Res       Date:  2008-02-08       Impact factor: 4.176

5.  Differences between sagittal femoral mechanical and distal reference axes should be considered in navigated TKA.

Authors:  Byung June Chung; Yeon Gwi Kang; Chong Bum Chang; Sung Ju Kim; Tae Kyun Kim
Journal:  Clin Orthop Relat Res       Date:  2009-02-26       Impact factor: 4.176

6.  Navigation did not improve the precision of minimally invasive knee arthroplasty.

Authors:  Peter M Bonutti; Daniel A Dethmers; Mike S McGrath; Slif D Ulrich; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2008-07-10       Impact factor: 4.176

7.  TKA sagittal alignment with navigation systems and conventional techniques vary only a few degrees.

Authors:  Yukihide Minoda; Akio Kobayashi; Hiroyoshi Iwaki; Hirotsugu Ohashi; Kunio Takaoka
Journal:  Clin Orthop Relat Res       Date:  2008-08-20       Impact factor: 4.176

8.  Determining femoral component position using CAS and measured resection.

Authors:  James Benjamin
Journal:  Clin Orthop Relat Res       Date:  2008-08-15       Impact factor: 4.176

Review 9.  Navigation knee replacement.

Authors:  Rupen Dattani; Surendra Patnaik; Avadhoot Kantak; Georgis Tselentakis
Journal:  Int Orthop       Date:  2008-10-29       Impact factor: 3.075

Review 10.  Current concepts and future perspectives in computer-assisted navigated total knee replacement.

Authors:  Tomoyuki Matsumoto; Naoki Nakano; John E Lawrence; Vikas Khanduja
Journal:  Int Orthop       Date:  2018-05-12       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.