Performance standards in positron emission tomography.

J S Karp1, M E Daube-Witherspoon, E J Hoffman, T K Lewellen, J M Links, W H Wong, R D Hichwa, M E Casey, J G Colsher, R E Hitchens.   

Abstract

A standard set of performance measurements is proposed for use with positron emission tomographs. This set of measurements has been developed jointly by the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. The measurements include tests of spatial resolution, scatter fraction, sensitivity, count rate losses and randoms, uniformity, scatter correction, attenuation correction, and count rate linearity correction.

Mesh:

Year:  1991        PMID: 1744726

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  14 in total

1.  Performance evaluation of microPET: a high-resolution lutetium oxyorthosilicate PET scanner for animal imaging.

Authors:  A F Chatziioannou; S R Cherry; Y Shao; R W Silverman; K Meadors; T H Farquhar; M Pedarsani; M E Phelps
Journal:  J Nucl Med       Date:  1999-07       Impact factor: 10.057

2.  Improved positron emission tomography quantification by Fourier-based restoration filtering.

Authors:  J M Links; J P Leal; H W Mueller-Gaertner; H N Wagner
Journal:  Eur J Nucl Med       Date:  1992

Review 3.  Small animal PET: aspects of performance assessment.

Authors:  Simone Weber; Andreas Bauer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-10-02       Impact factor: 9.236

4.  Performance of the new generation of whole-body PET/CT scanners: Discovery STE and Discovery VCT.

Authors:  M Teräs; T Tolvanen; J J Johansson; J J Williams; J Knuuti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-07-28       Impact factor: 9.236

5.  Performance evaluation of the new whole-body PET/CT scanner: Discovery ST.

Authors:  Valentino Bettinardi; Massimo Danna; Annarita Savi; Michela Lecchi; Isabella Castiglioni; Maria Carla Gilardi; Helmut Bammer; Giovanni Lucignani; Ferruccio Fazio
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02-10       Impact factor: 9.236

6.  A comparison of PET imaging characteristics of various copper radioisotopes.

Authors:  Heather Ann Williams; Simon Robinson; Peter Julyan; Jamal Zweit; David Hastings
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-10-29       Impact factor: 9.236

Review 7.  Multidetector single-photon emission tomography: are two (or three or four) heads really better than one?

Authors:  J M Links
Journal:  Eur J Nucl Med       Date:  1993-05

8.  Optimal dose of injection in activation study with O-15 water and PET.

Authors:  N Sadato; Y Yonekura; Y Magata; S Nishizawa; K Ishizu; H Okazawa; T Tsuchida; F Tanaka; N Tamaki; S Sasayama
Journal:  Ann Nucl Med       Date:  1994-11       Impact factor: 2.668

Review 9.  Scanner Design Considerations for Long Axial Field-of-View PET Systems.

Authors:  Margaret E Daube-Witherspoon; Simon R Cherry
Journal:  PET Clin       Date:  2020-11-05

10.  The suitability of gamma camera coincidence systems for nitrogen 13-labeled ammonia myocardial perfusion imaging: a quantitative comparison with full-ring PET.

Authors:  Fergus I McKiddie; Howard G Gemmell; E Joyce Davidson; Andrew Welch; Mohaned Egred
Journal:  J Nucl Cardiol       Date:  2003 Nov-Dec       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.