Literature DB >> 17410576

T1 measurement of flowing blood and arterial input function determination for quantitative 3D T1-weighted DCE-MRI.

Hai-Ling Margaret Cheng1.   

Abstract

PURPOSE: To propose a simple, accurate method for measuring T(1) in flowing blood and the arterial input function (AIF), and to evaluate the impact on dynamic contrast-enhanced MRI (DCE-MRI) quantification of pharmacokinetic parameters.
MATERIALS AND METHODS: A total of 10 rabbits were scanned at 1.5 Tesla and administered a bolus of Gadomer. Preinjection T(1) and AIF measurements were acquired in the iliac arteries using a rapid three-dimensional (3D) spoiled gradient recalled echo (SPGR) approach. Correction was made for imperfect B(1) fields, in-flow, and partial volume effects. DCE-MRI parameters blood volume (v(b)) and endothelial transfer constant (K(trans)) in resting skeletal muscle were estimated from pharmacokinetic analysis using individually measured AIFs. Literature comparisons were made to assess accuracy.
RESULTS: Blood T(1) was more accurate and precise after correction for B(1) and partial volume errors (1267 +/- 72 msec). Measured AIFs followed reported biexponential decay characteristics for Gadomer clearance in rabbits. Parameters v(b) (2.47 +/- 0.65%) and K(trans) (3.6 +/- 1.0 x 10(-3) minute(-1)) derived from AIFs based on corrected blood T(1)s were more reproducible and in better agreement with literature values.
CONCLUSION: The proposed method enables accurate in vivo blood T(1) and AIF measurements and can be easily implemented in a range of DCE-MRI applications to improve both the accuracy and reproducibility of pharmacokinetic parameters. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17410576     DOI: 10.1002/jmri.20898

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  25 in total

Review 1.  Review of treatment assessment using DCE-MRI in breast cancer radiation therapy.

Authors:  Chun-Hao Wang; Fang-Fang Yin; Janet Horton; Zheng Chang
Journal:  World J Methodol       Date:  2014-06-26

2.  A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: II. In vivo results.

Authors:  Matthias C Schabel; Edward V R DiBella; Randy L Jensen; Karen L Salzman
Journal:  Phys Med Biol       Date:  2010-08-03       Impact factor: 3.609

3.  A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: I. Simulations.

Authors:  Matthias C Schabel; Jacob U Fluckiger; Edward V R DiBella
Journal:  Phys Med Biol       Date:  2010-08-03       Impact factor: 3.609

4.  MRI and quantitative autoradiographic studies following bolus injections of unlabeled and (14)C-labeled gadolinium-diethylenetriaminepentaacetic acid in a rat model of stroke yield similar distribution volumes and blood-to-brain influx rate constants.

Authors:  Tavarekere N Nagaraja; James R Ewing; Kishor Karki; Paul E Jacobs; George W Divine; Joseph D Fenstermacher; Clifford S Patlak; Robert A Knight
Journal:  NMR Biomed       Date:  2010-12-12       Impact factor: 4.044

5.  Simultaneous variable flip angle-actual flip angle imaging method for improved accuracy and precision of three-dimensional T1 and B1 measurements.

Authors:  Samuel A Hurley; Vasily L Yarnykh; Kevin M Johnson; Aaron S Field; Andrew L Alexander; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

6.  Fast, reproducible measurement of the vascular input function in mice using constrained reconstruction and cardiac sampling.

Authors:  Dustin K Ragan; Stephen Y Lai; James A Bankson
Journal:  NMR Biomed       Date:  2010-09-22       Impact factor: 4.044

7.  A comparison of radial keyhole strategies for high spatial and temporal resolution 4D contrast-enhanced MRI in small animal tumor models.

Authors:  Ergys Subashi; Everett J Moding; Gary P Cofer; James R MacFall; David G Kirsch; Yi Qi; G Allan Johnson
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

8.  Four-dimensional transcatheter intraarterial perfusion (TRIP)-MRI for monitoring liver tumor embolization in VX2 rabbits.

Authors:  Dingxin Wang; Sumeet Virmani; Richard Tang; Barbara Szolc-Kowalska; Gayle Woloschak; Reed A Omary; Andrew C Larson
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

9.  Rapid 3D radiofrequency field mapping using catalyzed double-angle method.

Authors:  Dingxin Wang; Sven Zuehlsdorff; Andrew C Larson
Journal:  NMR Biomed       Date:  2009-10       Impact factor: 4.044

10.  Use of cardiac output to improve measurement of input function in quantitative dynamic contrast-enhanced MRI.

Authors:  Jeff L Zhang; Henry Rusinek; Louisa Bokacheva; Qun Chen; Pippa Storey; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2009-09       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.