Fast, reproducible measurement of the vascular input function in mice using constrained reconstruction and cardiac sampling.

Dustin K Ragan1, Stephen Y Lai, James A Bankson.   

Abstract

Dynamic contrast-enhanced MRI is often used to assess the response to therapy in small animal models of cancer. Rigorous quantification of dynamic contrast-enhanced MRI data using common pharmacokinetic models requires dynamic determination of the concentration of contrast in tumor tissue and in blood. Measurement of the blood concentration, or vascular input function (VIF), requires high temporal resolution and is prone to distortion as a result of flow and partial volume artifacts when measured in local blood vessels. We have developed a strategy for the robust measurement of VIF in mice that uses a constrained reconstruction algorithm to enable sampling from the left ventricle of the heart. The feasibility of the algorithm and its resistance to cardiac motion are demonstrated in vivo and through numerical simulations. VIF sampling is interleaved with slices dedicated to tumor coverage to yield a fast VIF sampling period (81 ms) that is decoupled from the temporal resolution of tumor data (3.9 s). The algorithm provides results that agree with fully encoded measurements in the slowly varying component of VIF to within a 4% root-mean-square signal difference. Analysis of a parametric representation of VIFs measured in a population of mice showed a significant reduction in variations observed within subjects (5%-58% over four parameters; p < 0.05) and a reduction in variations between subjects (19%-62%) when using this technique. Preliminary dynamic measurements in an orthotopic xenograft model of anaplastic thyroid cancer revealed a decrease in the variation of pharmacokinetic parameters between mice by a factor of two.
Copyright © 2010 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20862661      PMCID: PMC3033468          DOI: 10.1002/nbm.1601

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  22 in total

1.  Uncertainty in the analysis of tracer kinetics using dynamic contrast-enhanced T1-weighted MRI.

Authors:  David L Buckley
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

2.  Comparison of model-based arterial input functions for dynamic contrast-enhanced MRI in tumor bearing rats.

Authors:  Deirdre M McGrath; Daniel P Bradley; Jean L Tessier; Tony Lacey; Chris J Taylor; Geoffrey J M Parker
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

3.  Uncertainty and bias in contrast concentration measurements using spoiled gradient echo pulse sequences.

Authors:  Matthias C Schabel; Dennis L Parker
Journal:  Phys Med Biol       Date:  2008-04-17       Impact factor: 3.609

4.  Partial volume effect (PVE) on the arterial input function (AIF) in T1-weighted perfusion imaging and limitations of the multiplicative rescaling approach.

Authors:  Adam E Hansen; Henrik Pedersen; Egill Rostrup; Henrik B W Larsson
Journal:  Magn Reson Med       Date:  2009-10       Impact factor: 4.668

5.  Reproducibility of quantitative dynamic MRI of normal human tissues.

Authors:  Anwar R Padhani; Carmel Hayes; Sabine Landau; Martin O Leach
Journal:  NMR Biomed       Date:  2002-04       Impact factor: 4.044

6.  Reduced capillary perfusion and permeability in human tumour xenografts treated with the VEGF signalling inhibitor ZD4190: an in vivo assessment using dynamic MR imaging and macromolecular contrast media.

Authors:  C Pradel; N Siauve; G Bruneteau; O Clement; C de Bazelaire; F Frouin; S R Wedge; J L Tessier; P H Robert; G Frija; C A Cuenod
Journal:  Magn Reson Imaging       Date:  2003-10       Impact factor: 2.546

7.  A method for interleaved acquisition of a vascular input function for dynamic contrast-enhanced MRI in experimental rat tumours.

Authors:  Dominick J O McIntyre; Christian Ludwig; Amit Pasan; John R Griffiths
Journal:  NMR Biomed       Date:  2004-05       Impact factor: 4.044

8.  MRI estimation of the arterial input function in mice.

Authors:  Stephen Pickup; Rong Zhou; Jerry Glickson
Journal:  Acad Radiol       Date:  2003-09       Impact factor: 3.173

9.  Simultaneous measurement of arterial input function and tumor pharmacokinetics in mice by dynamic contrast enhanced imaging: effects of transcytolemmal water exchange.

Authors:  Rong Zhou; Stephen Pickup; Thomas E Yankeelov; Charles S Springer; Jerry D Glickson
Journal:  Magn Reson Med       Date:  2004-08       Impact factor: 4.668

10.  Effects of AZD2171 and vandetanib (ZD6474, Zactima) on haemodynamic variables in an SW620 human colon tumour model: an investigation using dynamic contrast-enhanced MRI and the rapid clearance blood pool contrast agent, P792 (gadomelitol).

Authors:  D P Bradley; J L Tessier; D Checkley; H Kuribayashi; J C Waterton; J Kendrew; S R Wedge
Journal:  NMR Biomed       Date:  2008-01       Impact factor: 4.044

View more
  5 in total

1.  Kinetic Modeling and Constrained Reconstruction of Hyperpolarized [1-13C]-Pyruvate Offers Improved Metabolic Imaging of Tumors.

Authors:  James A Bankson; Christopher M Walker; Marc S Ramirez; Wolfgang Stefan; David Fuentes; Matthew E Merritt; Jaehyuk Lee; Vlad C Sandulache; Yunyun Chen; Liem Phan; Ping-Chieh Chou; Arvind Rao; Sai-Ching J Yeung; Mong-Hong Lee; Dawid Schellingerhout; Charles A Conrad; Craig Malloy; A Dean Sherry; Stephen Y Lai; John D Hazle
Journal:  Cancer Res       Date:  2015-09-29       Impact factor: 12.701

2.  Radial spectroscopic MRI of hyperpolarized [1-(13) C] pyruvate at 7 tesla.

Authors:  Marc S Ramirez; Jaehyuk Lee; Christopher M Walker; Vlad C Sandulache; Franciszek Hennel; Stephen Y Lai; James A Bankson
Journal:  Magn Reson Med       Date:  2013-11-01       Impact factor: 4.668

Review 3.  High-field small animal magnetic resonance oncology studies.

Authors:  Louisa Bokacheva; Ellen Ackerstaff; H Carl LeKaye; Kristen Zakian; Jason A Koutcher
Journal:  Phys Med Biol       Date:  2013-12-30       Impact factor: 3.609

4.  Optimization of microCT imaging and blood vessel diameter quantitation of preclinical specimen vasculature with radiopaque polymer injection medium.

Authors:  Sergio X Vasquez; Feng Gao; Feng Su; Victor Grijalva; John Pope; Bill Martin; Jeroen Stinstra; Matthew Masner; Neha Shah; David M Weinstein; Robin Farias-Eisner; Srinivasa T Reddy
Journal:  PLoS One       Date:  2011-04-18       Impact factor: 3.240

5.  Dependence of DCE-MRI biomarker values on analysis algorithm.

Authors:  Chaan S Ng; Wei Wei; James A Bankson; Murali K Ravoori; Lin Han; David W Brammer; Sherry Klumpp; John C Waterton; Edward F Jackson
Journal:  PLoS One       Date:  2015-07-24       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.