Literature DB >> 17354143

Limited cone-beam computed tomography imaging of the middle ear: a comparison with multislice helical computed tomography.

L I Peltonen1, A A Aarnisalo, M K Kortesniemi, A Suomalainen, J Jero, S Robinson.   

Abstract

PURPOSE: To determine the applicability of cone-beam computed tomography (CBCT) in otological imaging, and to compare its accuracy with the routinely used multislice helical CT (MSCT) for imaging of the middle- and inner-ear areas.
MATERIAL AND METHODS: Thirteen unoperated human cadaver temporal bones were imaged with CBCT and MSCT. Sixteen landmarks of the middle and adjacent inner ear were evaluated and compared for their conspicuity according to a modified Likert scale. Total scores and scores for subgroups including landmarks of specific clinical interest were also compared.
RESULTS: No significant differences were found between the imaging techniques or subgroups when scores of individual structures were compared. While the middle ear itself was visible in all cases with CBCT, parts of the inner ear were "cut off" in four cases due to the limited field of view. For the same reason, the evaluation of the whole mastoid was not possible with CBCT. The cochlear and vestibular aqueducts were not visualized in either CT techniques. The contrast-to-noise ratio was more than 50% lower in CBCT than in MSCT, but still adequate for diagnostic task.
CONCLUSION: CBCT proved to be at least as accurate as routinely used MSCT in revealing the clinically and surgically important middle-ear structures. The results show that high-quality imaging of the middle ear is possible with the current CBCT device.

Entities:  

Mesh:

Year:  2007        PMID: 17354143     DOI: 10.1080/02841850601080465

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  20 in total

1.  Temporal bone imaging using digital volume tomography and computed tomography: a comparative cadaveric radiological study.

Authors:  Afshin Teymoortash; Stella Hamzei; Tobias Murthum; Behfar Eivazi; Ingo Kureck; Jochen A Werner
Journal:  Surg Radiol Anat       Date:  2010-08-13       Impact factor: 1.246

2.  Cone beam CT dose reduction in prostate radiotherapy using Likert scale methods.

Authors:  Keith A Langmack; Louise A Newton; Suzanne Jordan; Ruth Smith
Journal:  Br J Radiol       Date:  2015-12-21       Impact factor: 3.039

3.  Cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS flat panel detector: visibility of simulated microcalcifications.

Authors:  Youtao Shen; Yuncheng Zhong; Chao-Jen Lai; Tianpeng Wang; Chris C Shaw
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

Review 4.  Preoperative imaging procedures for lower wisdom teeth removal.

Authors:  Lennart Flygare; Anders Ohman
Journal:  Clin Oral Investig       Date:  2008-04-30       Impact factor: 3.573

5.  Visualization of anatomy in normal and pathologic middle ears by cone beam CT.

Authors:  Christian Güldner; Isabell Diogo; Eva Bernd; Stephanie Dräger; Magis Mandapathil; Afshin Teymoortash; Hesham Negm; Thomas Wilhelm
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-10-17       Impact factor: 2.503

Review 6.  Radiation dose in non-dental cone beam CT applications: a systematic review.

Authors:  Cosimo Nardi; Sergio Salerno; Roberto Molteni; Mariaelena Occhipinti; Giulia Grazzini; Niccolò Norberti; Cesare Cordopatri; Stefano Colagrande
Journal:  Radiol Med       Date:  2018-06-05       Impact factor: 3.469

7.  Ultrahigh-resolution CT scan of the temporal bone.

Authors:  Koji Yamashita; Akio Hiwatashi; Osamu Togao; Kazufumi Kikuchi; Nozomu Matsumoto; Daichi Momosaka; Hiroshi Nakatake; Yuki Sakai; Hiroshi Honda
Journal:  Eur Arch Otorhinolaryngol       Date:  2018-08-22       Impact factor: 2.503

8.  Trabecular bone histomorphometric measurements and contrast-to-noise ratio in CBCT.

Authors:  E Klintström; O Smedby; B Klintström; T B Brismar; R Moreno
Journal:  Dentomaxillofac Radiol       Date:  2014-08-29       Impact factor: 2.419

9.  Radiation dose saving through the use of cone-beam CT in hearing-impaired patients.

Authors:  N Faccioli; M Barillari; S Guariglia; E Zivelonghi; A Rizzotti; R Cerini; R Pozzi Mucelli
Journal:  Radiol Med       Date:  2009-09-30       Impact factor: 3.469

10.  Intraoperative use of cone-beam computed tomography in a cadaveric ossified cochlea model.

Authors:  Emma Barker; Keith Trimble; Harley Chan; James Ramsden; Sajendra Nithiananthan; Adrian James; Gideon Bachar; Mike Daly; Jonathan Irish; Jeff Siewerdsen
Journal:  Otolaryngol Head Neck Surg       Date:  2009-05       Impact factor: 3.497

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.