Intraoperative use of cone-beam computed tomography in a cadaveric ossified cochlea model.

Emma Barker1, Keith Trimble, Harley Chan, James Ramsden, Sajendra Nithiananthan, Adrian James, Gideon Bachar, Mike Daly, Jonathan Irish, Jeff Siewerdsen.   

Abstract

OBJECTIVES: To describe a cadaveric temporal bone model of labyrinthitis ossificans and investigate the utility of intraoperative cone-beam computed tomography (CBCT) in the facilitating cochlear implantation.
DESIGN: Cadaveric temporal bone study.
METHODS: Five cadaveric heads had cement introduced into the 10 cochleas. CBCT and a conventional CT scan were compared to assess the extent of cochlear obliteration. The cement was drilled-out (under CBCT guidance, if required) and cochlear implant electrode arrays (from 3 different manufacturers) inserted.
RESULTS: CBCT images demonstrated temporal bone anatomy and the extent of cochlear obliteration as clearly as conventional CT in all cases. Intraoperative CBCT guided drilling and facilitated electrode placement in two of five heads (3 of 10 ears). Streak-artifact from the electrodes of two devices partially obscured image clarity.
CONCLUSIONS: The obliterated cochlear model reproduced a disease-ossified cochlear both radiographically and surgically. CBCT is useful for intraoperative imaging to facilitate electrode array placement in the obliterated or congenitally abnormal cochlea.

Entities:  

Mesh:

Year:  2009        PMID: 19393414      PMCID: PMC2876243          DOI: 10.1016/j.otohns.2008.12.046

Source DB:  PubMed          Journal:  Otolaryngol Head Neck Surg        ISSN: 0194-5998            Impact factor:   3.497


  19 in total

1.  Postmeningitic ossification in pediatric cochlear implantation.

Authors:  N M Young; C A Hughes; S E Byrd; C Darling
Journal:  Otolaryngol Head Neck Surg       Date:  2000-02       Impact factor: 3.497

2.  Nondestructive three-dimensional analysis of electrode to modiolus proximity.

Authors:  Hartmut W Husstedt; Antje Aschendorff; Bernhard Richter; Roland Laszig; Martin Schumacher
Journal:  Otol Neurotol       Date:  2002-01       Impact factor: 2.311

3.  Scala vestibuli cochlear implantation in patients with partially ossified cochleas.

Authors:  Stefano Berrettini; Francesca Forli; Emanuele Neri; Giovanni Segnini; Stefano Sellari Franceschini
Journal:  J Laryngol Otol       Date:  2002-11       Impact factor: 1.469

4.  Investigation of C-arm cone-beam CT-guided surgery of the frontal recess.

Authors:  M A Rafferty; J H Siewerdsen; Y Chan; D J Moseley; M J Daly; D A Jaffray; J C Irish
Journal:  Laryngoscope       Date:  2005-12       Impact factor: 3.325

5.  Intraoperative cone-beam CT for guidance of temporal bone surgery.

Authors:  Mark A Rafferty; Jeffrey H Siewerdsen; Yvonne Chan; Michael J Daly; Douglas J Moseley; David A Jaffray; Jonathan C Irish
Journal:  Otolaryngol Head Neck Surg       Date:  2006-05       Impact factor: 3.497

6.  Survey of prophylactic antibiotic use amongst UK cochlear implant surgeons.

Authors:  Emma Barker; Mike Pringle
Journal:  Cochlear Implants Int       Date:  2008-06

7.  How we do it: using a surgical navigation system in the management of the ossified cochlea.

Authors:  C H Raine; D R Strachan; T Gopichandran
Journal:  Cochlear Implants Int       Date:  2003-06

8.  Endoscopic sinus surgery using intraoperative computed tomography imaging for updating a three-dimensional navigation system.

Authors:  M Cartellieri; F Vorbeck
Journal:  Laryngoscope       Date:  2000-02       Impact factor: 3.325

9.  Implementation of 3D-virtual brachytherapy in the management of breast cancer: a description of a new method of interstitial brachytherapy.

Authors:  F A Vicini; D A Jaffray; E M Horwitz; G K Edmundson; D A DeBiose; V R Kini; A A Martinez
Journal:  Int J Radiat Oncol Biol Phys       Date:  1998-02-01       Impact factor: 7.038

10.  Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype.

Authors:  M J Daly; J H Siewerdsen; D J Moseley; D A Jaffray; J C Irish
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

View more
  11 in total

1.  Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach.

Authors:  Sajendra Nithiananthan; Sebastian Schafer; Ali Uneri; Daniel J Mirota; J Webster Stayman; Wojciech Zbijewski; Kristy K Brock; Michael J Daly; Harley Chan; Jonathan C Irish; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

2.  Mobile C-arm cone-beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance.

Authors:  S Schafer; S Nithiananthan; D J Mirota; A Uneri; J W Stayman; W Zbijewski; C Schmidgunst; G Kleinszig; A J Khanna; J H Siewerdsena
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

3.  Deformable registration of the inflated and deflated lung in cone-beam CT-guided thoracic surgery: initial investigation of a combined model- and image-driven approach.

Authors:  Ali Uneri; Sajendra Nithiananthan; Sebastian Schafer; Yoshito Otake; J Webster Stayman; Gerhard Kleinszig; Marc S Sussman; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

4.  Atlas-Based Segmentation of Temporal Bone Anatomy.

Authors:  Kimerly A Powell; Tong Liang; Brad Hittle; Don Stredney; Thomas Kerwin; Gregory J Wiet
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-08-29       Impact factor: 2.924

5.  Implantation of the completely ossified cochlea: an image-guided approach.

Authors:  George B Wanna; Matthew L Carlson; Grégoire S Blachon; Jack H Noble; Benoit M Dawant; Robert F Labadie; Ramya Balachandran
Journal:  Otol Neurotol       Date:  2013-04       Impact factor: 2.311

6.  Overcoming Nonlinear Partial Volume Effects in Known-Component Reconstruction of Cochlear Implants.

Authors:  J W Stayman; H Dang; Y Otake; W Zbijewski; J Noble; B Dawant; R Labadie; J P Carey; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013

7.  Cone-Beam CT with a Flat-Panel Detector: From Image Science to Image-Guided Surgery.

Authors:  Jeffrey H Siewerdsen
Journal:  Nucl Instrum Methods Phys Res A       Date:  2011-08-21       Impact factor: 1.455

8.  Integration of free-hand 3D ultrasound and mobile C-arm cone-beam CT: Feasibility and characterization for real-time guidance of needle insertion.

Authors:  E Marinetto; A Uneri; T De Silva; S Reaungamornrat; W Zbijewski; A Sisniega; S Vogt; G Kleinszig; J Pascau; J H Siewerdsen
Journal:  Comput Med Imaging Graph       Date:  2017-04-03       Impact factor: 7.422

9.  An electromagnetic "Tracker-in-Table" configuration for X-ray fluoroscopy and cone-beam CT-guided surgery.

Authors:  J Yoo; S Schafer; A Uneri; Y Otake; A J Khanna; J H Siewerdsen
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-05-15       Impact factor: 3.421

10.  Robust methods for automatic image-to-world registration in cone-beam CT interventional guidance.

Authors:  H Dang; Y Otake; S Schafer; J W Stayman; G Kleinszig; J H Siewerdsen
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.506

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.