Literature DB >> 1734069

Controlled evaluation of BACTEC PLUS 27 and Roche Septi-Chek anaerobic blood culture bottles.

M L Wilson1, L J Harrell, S Mirrett, M P Weinstein, C W Stratton, L B Reller.   

Abstract

Becton Dickinson Diagnostic Instrument Systems (Sparks, Md.) recently introduced BACTEC high-volume aerobic and anaerobic bottles that accept up to 10 ml of blood for use on their nonradiometric blood culture instruments. Both bottles contain 25 ml of tryptic soy broth, 0.05% sodium polyanetholesulfonate, and mixed resins. We compared the anaerobic bottle, designated BACTEC PLUS 27 (BP27), with the Roche Septi-Chek (RSC) Columbia broth anaerobic bottle in a collaborative evaluation at three university hospitals. A total of 5,152 adequately filled blood cultures were obtained from adult patients with suspected bacteremia or fungemia. Staphylococcus aureus was recovered significantly more often (P less than 0.03) from BP27 bottles alone; there were no other significant differences in yield. When microorganisms were recovered from both anaerobic bottles, growth was detected earlier in BP27 than it was in RSC (P less than 0.001), especially for S. aureus (P less than 0.001) and Staphylococcus epidermidis (P less than 0.02). We conclude that the yield from BP27 bottles is equivalent to or better (S. aureus) than that from RSC anaerobic bottles with Columbia broth and that speed of detection is superior with BP27 bottles.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1734069      PMCID: PMC264997          DOI: 10.1128/jcm.30.1.63-66.1992

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  12 in total

1.  The causative organisms of septicaemia and their epidemiology.

Authors:  S J Eykyn; W R Gransden; I Phillips
Journal:  J Antimicrob Chemother       Date:  1990-04       Impact factor: 5.790

2.  Controlled evaluation of BACTEC Plus 26 and Roche Septi-Chek aerobic blood culture bottles.

Authors:  M P Weinstein; S Mirrett; M L Wilson; L J Harrell; C W Stratton; L B Reller
Journal:  J Clin Microbiol       Date:  1991-05       Impact factor: 5.948

3.  Specimen volume versus yield in the BACTEC blood culture system.

Authors:  J J Plorde; F C Tenover; L G Carlson
Journal:  J Clin Microbiol       Date:  1985-08       Impact factor: 5.948

4.  The importance of volume of blood cultured in the detection of bacteremia and fungemia.

Authors:  D M Ilstrup; J A Washington
Journal:  Diagn Microbiol Infect Dis       Date:  1983-06       Impact factor: 2.803

5.  A review of positive blood cultures: identification and source of microorganisms and patterns of sensitivity to antibiotics.

Authors:  F J Roberts
Journal:  Rev Infect Dis       Date:  1980 May-Jun

6.  The importance of blood volume cultured on detection of bacteraemia.

Authors:  P Sandven; E A Høiby
Journal:  Acta Pathol Microbiol Scand B       Date:  1981-06

7.  Importance of blood volume cultured in the detection of bacteremia.

Authors:  M Arpi; M W Bentzon; J Jensen; W Frederiksen
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

8.  Anaerobic bacteremia: decreasing rate over a 15-year period.

Authors:  C W Dorsher; J E Rosenblatt; W R Wilson; D M Ilstrup
Journal:  Rev Infect Dis       Date:  1991 Jul-Aug

9.  Controlled evaluation of the volume of blood cultured in detection of bacteremia and fungemia.

Authors:  J H Tenney; L B Reller; S Mirrett; W L Wang; M P Weinstein
Journal:  J Clin Microbiol       Date:  1982-04       Impact factor: 5.948

10.  Comparison of recovery of organisms from blood cultures diluted 10% (volume/volume) and 20% (volume/volume).

Authors:  R Auckenthaler; D M Ilstrup; J A Washington
Journal:  J Clin Microbiol       Date:  1982-05       Impact factor: 5.948

View more
  15 in total

1.  Controlled clinical comparison of BACTEC plus anaerobic/F to standard anaerobic/F as the anaerobic companion bottle to plus aerobic/F medium for culturing blood from adults.

Authors:  M L Wilson; S Mirrett; F T Meredith; M P Weinstein; V Scotto; L B Reller
Journal:  J Clin Microbiol       Date:  2001-03       Impact factor: 5.948

Review 2.  Update on detection of bacteremia and fungemia.

Authors:  L G Reimer; M L Wilson; M P Weinstein
Journal:  Clin Microbiol Rev       Date:  1997-07       Impact factor: 26.132

3.  Value of terminal subcultures for blood cultures monitored by BACTEC 9240.

Authors:  M P Weinstein; S Mirrett; L B Reller; L G Reimer; M L Wilson
Journal:  J Clin Microbiol       Date:  1996-01       Impact factor: 5.948

4.  Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure.

Authors:  L Coorevits; A-M Van den Abeele
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2015-04-17       Impact factor: 3.267

5.  Controlled clinical laboratory comparison of BACTEC plus aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemia.

Authors:  J H Jorgensen; S Mirrett; L C McDonald; P R Murray; M P Weinstein; J Fune; C W Trippy; M Masterson; L B Reller
Journal:  J Clin Microbiol       Date:  1997-01       Impact factor: 5.948

6.  Detection kinetics for positive blood culture bottles by using the VITAL automated system.

Authors:  H Marchandin; B Compan; M Simeon De Buochberg; E Despaux; C Perez
Journal:  J Clin Microbiol       Date:  1995-08       Impact factor: 5.948

7.  Value of terminal subcultures for blood cultures monitored by BACTEC 9240.

Authors:  J T Shigei; J A Shimabukuro; M T Pezzlo; L M de la Maza; E M Peterson
Journal:  J Clin Microbiol       Date:  1995-05       Impact factor: 5.948

8.  Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia.

Authors:  M P Weinstein; S Mirrett; L G Reimer; M L Wilson; S Smith-Elekes; C R Chuard; K L Joho; L B Reller
Journal:  J Clin Microbiol       Date:  1995-04       Impact factor: 5.948

9.  Anaerobic bacteraemia in an Australian teaching hospital.

Authors:  T V Riley; M A Aravena
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1995-01       Impact factor: 3.267

10.  Controlled clinical comparison of the BacT/ALERT FN and the standard anaerobic SN blood culture medium.

Authors:  S Mirrett; C A Petti; C W Woods; R Magadia; M P Weinstein; L B Reller
Journal:  J Clin Microbiol       Date:  2004-10       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.