Literature DB >> 15472312

Controlled clinical comparison of the BacT/ALERT FN and the standard anaerobic SN blood culture medium.

S Mirrett1, C A Petti, C W Woods, R Magadia, M P Weinstein, L B Reller.   

Abstract

To determine the optimal anaerobic companion bottle to pair with the BacT/ALERT (bioMerieux, Durham, N.C.) nonvented aerobic FA (FA) medium for recovery of pathogenic microorganisms from adult patients with bacteremia and fungemia, we compared the BacT/ALERT FN (FN) anaerobic bottle with the standard BacT/ALERT SN (SN) anaerobic bottle. Each bottle, FA, FN, and SN, was filled with 8 to 12 ml of blood. Of 11,498 blood culture sets received in the clinical microbiology laboratories at two university medical centers, 7,945 sets had all three bottles filled adequately and 8,569 had both anaerobic bottles filled adequately. Of 686 clinically important (based on previously published criteria) isolates detected in one or both adequately filled anaerobic bottles, more staphylococci (P < 0.001), including Staphylococcus aureus (P < 0.001); members of the family Enterobacteriaceae (P < 0.001); and all microorganisms combined (P < 0.001) were detected in FN bottles. In contrast, more Pseudomonas aeruginosa isolates (P < 0.01) and yeasts (P < 0.001) were detected in SN bottles. More Bacteroides fragilis group bacteremias were detected only in the FN (six) than in the SN (one) anaerobic bottle (P = not significant). Overall, the mean time to detection was shorter with FN (16.8 h) than with SN (18.2 h). This difference in time to detection was greatest for the B. fragilis group: FN, 28 h, versus SN, 60.0 h. Many of the facultative microorganisms recovered in either FN or SN were also found in the companion FA. When microorganisms found in the companion FA bottle were omitted from the analysis, significantly more staphylococci (P < 0.001), including S. aureus (P < 0.001), and Enterobacteriaceae (P < 0.005) still were detected in FN bottles, whereas there were no significant differences for P. aeruginosa and yeasts, which were found as expected in FA bottles. We conclude that the companion anaerobic FN bottle detects more microorganisms than does the anaerobic SN bottle when used in conjunction with the nonvented aerobic FA bottle in the BacT/ALERT blood culture system.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15472312      PMCID: PMC522352          DOI: 10.1128/JCM.42.10.4581-4585.2004

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  8 in total

1.  Controlled clinical comparison of BACTEC plus anaerobic/F to standard anaerobic/F as the anaerobic companion bottle to plus aerobic/F medium for culturing blood from adults.

Authors:  M L Wilson; S Mirrett; F T Meredith; M P Weinstein; V Scotto; L B Reller
Journal:  J Clin Microbiol       Date:  2001-03       Impact factor: 5.948

2.  Controlled comparative evaluation of BacT/Alert FAN and ESP 80A aerobic media as means for detecting bacteremia and fungemia.

Authors:  G V Doern; A Barton; S Rao
Journal:  J Clin Microbiol       Date:  1998-09       Impact factor: 5.948

3.  The clinical significance of positive blood cultures in the 1990s: a prospective comprehensive evaluation of the microbiology, epidemiology, and outcome of bacteremia and fungemia in adults.

Authors:  M P Weinstein; M L Towns; S M Quartey; S Mirrett; L G Reimer; G Parmigiani; L B Reller
Journal:  Clin Infect Dis       Date:  1997-04       Impact factor: 9.079

4.  Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia.

Authors:  M P Weinstein; S Mirrett; L G Reimer; M L Wilson; S Smith-Elekes; C R Chuard; K L Joho; L B Reller
Journal:  J Clin Microbiol       Date:  1995-04       Impact factor: 5.948

5.  Rationale for selective use of anaerobic blood cultures.

Authors:  A J Morris; M L Wilson; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1993-08       Impact factor: 5.948

6.  Clinical importance of increased sensitivity of BacT/Alert FAN aerobic and anaerobic blood culture bottles.

Authors:  L C McDonald; J Fune; L B Gaido; M P Weinstein; L G Reimer; T M Flynn; M L Wilson; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1996-09       Impact factor: 5.948

7.  Controlled evaluation of BACTEC PLUS 27 and Roche Septi-Chek anaerobic blood culture bottles.

Authors:  M L Wilson; L J Harrell; S Mirrett; M P Weinstein; C W Stratton; L B Reller
Journal:  J Clin Microbiol       Date:  1992-01       Impact factor: 5.948

8.  Controlled evaluation of BacT/alert standard anaerobic and FAN anaerobic blood culture bottles for the detection of bacteremia and fungemia.

Authors:  M L Wilson; M P Weinstein; S Mirrett; L G Reimer; R J Feldman; C R Chuard; L B Reller
Journal:  J Clin Microbiol       Date:  1995-09       Impact factor: 5.948

  8 in total
  11 in total

1.  Controlled Evaluation of the New BacT/Alert Virtuo Blood Culture System for Detection and Time to Detection of Bacteria and Yeasts.

Authors:  Osman Altun; Mohammed Almuhayawi; Petra Lüthje; Rubina Taha; Måns Ullberg; Volkan Özenci
Journal:  J Clin Microbiol       Date:  2016-02-03       Impact factor: 5.948

2.  Biographical feature: Melvin P. Weinstein, M.D.

Authors:  Betty A Forbes
Journal:  J Clin Microbiol       Date:  2013-06-05       Impact factor: 5.948

3.  Comparative analysis of two broad-range PCR assays for pathogen detection in positive-blood-culture bottles: PCR-high-resolution melting analysis versus PCR-mass spectrometry.

Authors:  Kevin Jeng; Charlotte A Gaydos; Lawrence B Blyn; Samuel Yang; Helen Won; Heather Matthews; Donna Toleno; Yu-Hsiang Hsieh; Karen C Carroll; Justin Hardick; Billy Masek; Alexander Kecojevic; Rangarajan Sampath; Stephen Peterson; Richard E Rothman
Journal:  J Clin Microbiol       Date:  2012-08-01       Impact factor: 5.948

4.  Application of a 16S rRNA PCR-high-resolution melt analysis assay for rapid detection of Salmonella Bacteremia.

Authors:  Kevin Jeng; Samuel Yang; Helen Won; Charlotte A Gaydos; Yu-Hsiang Hsieh; Alex Kecojevic; Karen C Carroll; Justin Hardick; Richard E Rothman
Journal:  J Clin Microbiol       Date:  2012-01-11       Impact factor: 5.948

5.  Predominance of Enterobacteriaceae isolates in early positive anaerobic blood culture bottles in BacT/Alert system.

Authors:  Tzong-Shi Chiueh; Shih-Yi Lee; Sheng-Hui Tang; Jang-Jih Lu; Jun-Ren Sun
Journal:  J Clin Lab Anal       Date:  2013-01-24       Impact factor: 2.352

6.  Performance of two resin-containing blood culture media in detection of bloodstream infections and in direct matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) broth assays for isolate identification: clinical comparison of the BacT/Alert Plus and Bactec Plus systems.

Authors:  Barbara Fiori; Tiziana D'Inzeo; Viviana Di Florio; Flavio De Maio; Giulia De Angelis; Alessia Giaquinto; Lara Campana; Eloisa Tanzarella; Mario Tumbarello; Massimo Antonelli; Maurizio Sanguinetti; Teresa Spanu
Journal:  J Clin Microbiol       Date:  2014-07-16       Impact factor: 5.948

7.  Clinical evaluation of BacT/Alert FA plus and FN plus bottles compared with standard bottles.

Authors:  Dong-Hyun Lee; Seong Chun Kim; In-Gyu Bae; Eun-Ha Koh; Sunjoo Kim
Journal:  J Clin Microbiol       Date:  2013-10-09       Impact factor: 5.948

8.  Controlled clinical comparison of new pediatric medium with adsorbent polymeric beads (PF Plus) versus charcoal-containing PF medium in the BacT/alert blood culture system.

Authors:  Christopher D Doern; Stanley Mirrett; Diane Halstead; Joan Abid; Pamela Okada; L Barth Reller
Journal:  J Clin Microbiol       Date:  2014-03-19       Impact factor: 5.948

Review 9.  How to Optimize the Use of Blood Cultures for the Diagnosis of Bloodstream Infections? A State-of-the Art.

Authors:  Brigitte Lamy; Sylvie Dargère; Maiken C Arendrup; Jean-Jacques Parienti; Pierre Tattevin
Journal:  Front Microbiol       Date:  2016-05-12       Impact factor: 5.640

10.  Performance Survey and Comparison Between Rapid Sterility Testing Method and Pharmacopoeia Sterility Test.

Authors:  Adriana Bugno; Deborah Pita Sanches Saes; Adriana Aparecida Buzzo Almodovar; Kamal Dua; Rajendra Awasthi; Daniela Dal Molim Ghisleni; Marici Tiomi Hirota; Wesley Anderson de Oliveira; Terezinha de Jesus Andreoli Pinto
Journal:  J Pharm Innov       Date:  2017-12-05       Impact factor: 2.750

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.