Literature DB >> 17327651

Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy.

George X Ding1, Dennis M Duggan, Charles W Coffey.   

Abstract

The purpose of this investigation is to characterize the beams produced by a kilovoltage (kV) imager integrated into a linear accelerator (Varian on-board imager integrated into the Trilogy accelerator) for acquiring high resolution volumetric cone-beam computed tomography (CBCT) images of the patient on the treatment table. The x-ray tube is capable of generating photon spectra with kVp values between 40 and 125 kV. The Monte Carlo simulations were used to study the characteristics of kV beams and the properties of imaged target scatters. The Monte Carlo results were benchmarked against measurements, and excellent agreements were obtained. We also studied the effect of including the electron impact ionization (EII), and the simulation showed that the characteristic radiation is increased significantly in the energy spectra when EII is included. Although only slight beam hardening is observed in the spectra of all photons after passing through the phantom target, there is a significant difference in the spectra and angular distributions between scattered and primary photons. The results also show that the photon fluence distributions are significantly altered by adding bow tie filters. The results indicate that a combination of large cone-beam field size and large imaged target significantly increases scatter-to-primary ratios for photons that reach the detector panel. For phantoms 10 cm, 20 cm and 30 cm thick of water placed at the isocentre, the scatter-to-primary ratios are 0.94, 3.0 and 7.6 respectively for an open 125 kVp CBCT beam. The Monte Carlo simulations show that the increase of the scatter is proportional to the increase of the imaged volume, and this also applies to scatter-to-primary ratios. This study shows both the magnitude and the characteristics of scattered x-rays. The knowledge obtained from this investigation may be useful in the future design of the image detector to improve the image quality.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17327651     DOI: 10.1088/0031-9155/52/6/004

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  19 in total

1.  Region-of-interest image reconstruction with intensity weighting in circular cone-beam CT for image-guided radiation therapy.

Authors:  Seungryong Cho; Erik Pearson; Charles A Pelizzari; Xiaochuan Pan
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

2.  Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations.

Authors:  Kyle McMillan; Michael McNitt-Gray; Dan Ruan
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

3.  Bowtie filtration for dedicated cone beam CT of the head and neck: a simulation study.

Authors:  G Zhang; N Marshall; R Jacobs; Q Liu; H Bosmans
Journal:  Br J Radiol       Date:  2013-05-31       Impact factor: 3.039

4.  Co-registration of cone beam CT and planning CT in head and neck IMRT dose estimation: a feasible adaptive radiotherapy strategy.

Authors:  C Yip; C Thomas; A Michaelidou; D James; R Lynn; M Lei; T Guerrero Urbano
Journal:  Br J Radiol       Date:  2013-11-28       Impact factor: 3.039

5.  Monte Carlo calculation of imaging doses from diagnostic multidetector CT and kilovoltage cone-beam CT as part of prostate cancer treatment plans.

Authors:  Aiping Ding; Jianwei Gu; Alexei V Trofimov; X George Xu
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

6.  Impact of reduction of flux overlap region on kilovoltage cone-beam computed tomography image quality and patients' exposure dose.

Authors:  Daisuke Kawahara; Shuichi Ozawa; Yuji Murakami; Takeo Nakashima; Masamichi Aita; Shintaro Tsuda; Yusuke Ochi; Takuro Okumura; Hirokazu Masuda; Yoshimi Ohno; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2016-05-16

7.  Optimization of the geometry and speed of a moving blocker system for cone-beam computed tomography scatter correction.

Authors:  Xi Chen; Luo Ouyang; Hao Yan; Xun Jia; Bin Li; Qingwen Lyu; You Zhang; Jing Wang
Journal:  Med Phys       Date:  2017-09       Impact factor: 4.071

8.  Use of kilovoltage X-ray volume imaging in patient dose calculation for head-and-neck and partial brain radiation therapy.

Authors:  Weigang Hu; Jinsong Ye; Jiazhou Wang; Xuejun Ma; Zhen Zhang
Journal:  Radiat Oncol       Date:  2010-04-19       Impact factor: 3.481

9.  The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations.

Authors:  J Gu; B Bednarz; P F Caracappa; X G Xu
Journal:  Phys Med Biol       Date:  2009-04-08       Impact factor: 3.609

10.  Radiation dose to procedural personnel and patients from an X-ray volume imaging system.

Authors:  Jijo Paul; Emmanuel C Mbalisike; Thomas J Vogl
Journal:  Eur Radiol       Date:  2013-06-29       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.