Literature DB >> 19472624

Region-of-interest image reconstruction with intensity weighting in circular cone-beam CT for image-guided radiation therapy.

Seungryong Cho1, Erik Pearson, Charles A Pelizzari, Xiaochuan Pan.   

Abstract

Imaging plays a vital role in radiation therapy and with recent advances in technology considerable emphasis has been placed on cone-beam CT (CBCT). Attaching a kV x-ray source and a flat panel detector directly to the linear accelerator gantry has enabled progress in target localization techniques, which can include daily CBCT setup scans for some treatments. However, with an increasing number of CT scans there is also an increasing concern for patient exposure. An intensity-weighted region-of-interest (IWROI) technique, which has the potential to greatly reduce CBCT dose, in conjunction with the chord-based backprojection-filtration (BPF) reconstruction algorithm, has been developed and its feasibility in clinical use is demonstrated in this article. A nonuniform filter is placed in the x-ray beam to create regions of two different beam intensities. In this manner, regions outside the target area can be given a reduced dose but still visualized with a lower contrast to noise ratio. Image artifacts due to transverse data truncation, which would have occurred in conventional reconstruction algorithms, are avoided and image noise levels of the low- and high-intensity regions are well controlled by use of the chord-based BPF reconstruction algorithm. The proposed IWROI technique can play an important role in image-guided radiation therapy.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19472624      PMCID: PMC2673679          DOI: 10.1118/1.3085825

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  Image reconstruction on PI-lines by use of filtered backprojection in helical cone-beam CT.

Authors:  Yu Zou; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2004-06-21       Impact factor: 3.609

2.  Reduction of ring artefacts in high resolution micro-CT reconstructions.

Authors:  Jan Sijbers; Andrei Postnov
Journal:  Phys Med Biol       Date:  2004-07-21       Impact factor: 3.609

3.  Theory and algorithms for image reconstruction on chords and within regions of interest.

Authors:  Yu Zou; Xiaochuan Pan; Emil Y Sidky
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2005-11       Impact factor: 2.129

4.  PI-line-based image reconstruction in helical cone-beam computed tomography with a variable pitch.

Authors:  Yu Zou; Xiaochuan Pan; Dan Xia; Ge Wang
Journal:  Med Phys       Date:  2005-08       Impact factor: 4.071

Review 5.  Emergent technologies for 3-dimensional image-guided radiation delivery.

Authors:  David A Jaffray
Journal:  Semin Radiat Oncol       Date:  2005-07       Impact factor: 5.934

6.  Region of interest reconstruction from truncated data in circular cone-beam CT.

Authors:  Lifeng Yu; Yu Zou; Emil Y Sidky; Charles A Pelizzari; Peter Munro; Xiaochuan Pan
Journal:  IEEE Trans Med Imaging       Date:  2006-07       Impact factor: 10.048

Review 7.  Imaging and alignment for image-guided radiation therapy.

Authors:  James M Balter; Marc L Kessler
Journal:  J Clin Oncol       Date:  2007-03-10       Impact factor: 44.544

8.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75.

Authors:  Martin J Murphy; James Balter; Stephen Balter; Jose A BenComo; Indra J Das; Steve B Jiang; C M Ma; Gustavo H Olivera; Raymond F Rodebaugh; Kenneth J Ruchala; Hiroki Shirato; Fang-Fang Yin
Journal:  Med Phys       Date:  2007-10       Impact factor: 4.071

9.  Noise properties of chord-image reconstruction.

Authors:  Dan Xia; Lifeng Yu; Emil Y Sidky; Yu Zou; Nianming Zuo; Xiaochuan Pan
Journal:  IEEE Trans Med Imaging       Date:  2007-10       Impact factor: 10.048

10.  Region-of-interest image reconstruction in circular cone-beam microCT.

Authors:  Seungryong Cho; Junguo Bian; Charles A Pelizzari; Chin-Tu Chen; Tong-Chuan He; Xiaochuan Pan
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

View more
  10 in total

1.  Volume-of-interest imaging of the inner ear in a human temporal bone specimen using a robot- driven C-arm flat panel detector CT system.

Authors:  D Kolditz; T Struffert; Y Kyriakou; A Bozzato; A Dörfler; W A Kalender
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-11       Impact factor: 3.825

2.  Reconstructing cone-beam CT with spatially varying qualities for adaptive radiotherapy: a proof-of-principle study.

Authors:  Wenting Lu; Hao Yan; Xuejun Gu; Zhen Tian; Ouyang Luo; Liu Yang; Linghong Zhou; Laura Cervino; Jing Wang; Steve Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2014-09-26       Impact factor: 3.609

Review 3.  The meaning of interior tomography.

Authors:  Ge Wang; Hengyong Yu
Journal:  Phys Med Biol       Date:  2013-08-02       Impact factor: 3.609

4.  Deformable image registration of CT and truncated cone-beam CT for adaptive radiation therapy.

Authors:  Xin Zhen; Hao Yan; Linghong Zhou; Xun Jia; Steve B Jiang
Journal:  Phys Med Biol       Date:  2013-10-30       Impact factor: 3.609

5.  Two-dimensional dynamic fluid bowtie attenuators.

Authors:  James R Hermus; Timothy P Szczykutowicz
Journal:  J Med Imaging (Bellingham)       Date:  2016-01-22

6.  Temporally downsampled cerebral CT perfusion image restoration using deep residual learning.

Authors:  Haichen Zhu; Dan Tong; Lu Zhang; Shijie Wang; Weiwen Wu; Hui Tang; Yang Chen; Limin Luo; Jian Zhu; Baosheng Li
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-10-31       Impact factor: 2.924

7.  Half-Fan-Based Intensity-Weighted Region-of-Interest Imaging for Low-Dose Cone-Beam CT in Image-Guided Radiation Therapy.

Authors:  Boyeol Yoo; Kihong Son; Rizza Pua; Jinsung Kim; Alexander Solodov; Seungryong Cho
Journal:  Healthc Inform Res       Date:  2016-10-31

8.  Optimal dose reduction algorithm using an attenuation-based tube current modulation method for cone-beam CT imaging.

Authors:  Kihong Son; Jieun Chang; Hoyeon Lee; Changhwan Kim; Taewon Lee; Seungryong Cho; Sohyun Park; Jin Sung Kim
Journal:  PLoS One       Date:  2018-02-15       Impact factor: 3.240

9.  Improving image accuracy of region-of-interest in cone-beam CT using prior image.

Authors:  Jiseoc Lee; Jin Sung Kim; Seungryong Cho
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

10.  Feasibility study of shutter scan acquisition for region of interest (ROI) digital tomosynthesis.

Authors:  Dohyeon Kim; Byungdu Jo; Donghoon Lee; Haenghwa Lee; Sunghoon Choi; Hyemi Kim; Zhen Chao; Seungyeon Choi; Hee-Joung Kim
Journal:  J Appl Clin Med Phys       Date:  2018-03-01       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.