Literature DB >> 22442056

Dynamically applied B1+ shimming solutions for non-contrast enhanced renal angiography at 7.0 Tesla.

Gregory J Metzger1, Edward J Auerbach, Can Akgun, Josh Simonson, Xiaoming Bi, Kâmil Uğurbil, Pierre-François van de Moortele.   

Abstract

The purpose of this study was to detail a strategy for performing non-contrast enhanced renal magnetic resonance angiography studies at 7.0 T. It is demonstrated that with proper B1+ management, these studies can be successfully performed at ultrahigh field within local specific absorption rate constraints. An inversion prepared gradient echo acquisition, standard for non-contrast renal magnetic resonance angiography studies, required radiofrequency pulse specific B 1+ shimming solutions to be dynamically applied to address the field dependent increases in both B(0) and B1+ inhomogeneity as well as to accommodate limitation in available power. By using more efficient B1+ shimming solutions for the inversion preparation and more homogeneous solutions for the excitation, high quality images of the renal arteries were obtained without venous and background signal artifacts while working within hardware and safety constraints. Finite difference time domain simulations confirmed in vivo measurements with respect to B1+ distributions and homogeneity for the range of shimming strategies used and allowed the calculation of peak local specific absorption rate values normalized by input power and B1+. Increasing B1+ homogeneity was accompanied by decreasing local specific absorption rate per Watt and increasing maximum local specific absorption rate per [B1+](2), which must be considered, along with body size and respiratory rate, when finalizing acquisition parameters for a given individual.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22442056      PMCID: PMC3387512          DOI: 10.1002/mrm.24237

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images.

Authors:  J T Vaughan; M Garwood; C M Collins; W Liu; L DelaBarre; G Adriany; P Andersen; H Merkle; R Goebel; M B Smith; K Ugurbil
Journal:  Magn Reson Med       Date:  2001-07       Impact factor: 4.668

2.  Steady-state free precession MRA of the renal arteries: breath-hold and navigator-gated techniques vs. CE-MRA.

Authors:  Jeffrey H Maki; Gregory J Wilson; William B Eubank; David J Glickerman; Sudhakar Pipavath; Romhild M Hoogeveen
Journal:  J Magn Reson Imaging       Date:  2007-10       Impact factor: 4.813

3.  A geometrically adjustable 16-channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Johannes Ritter; Steen Moeller; Edward J Auerbach; Can Akgün; Carl J Snyder; Thomas Vaughan; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2008-03       Impact factor: 4.668

4.  Renal transplant: nonenhanced renal MR angiography with magnetization-prepared steady-state free precession.

Authors:  Xin Liu; Natasha Berg; John Sheehan; Xiaoming Bi; Peter Weale; Renate Jerecic; James Carr
Journal:  Radiology       Date:  2009-03-04       Impact factor: 11.105

5.  Renal artery assessment with nonenhanced steady-state free precession versus contrast-enhanced MR angiography.

Authors:  Rolf Wyttenbach; Antonio Braghetti; Michael Wyss; Mario Alerci; Lukas Briner; Paolo Santini; Luca Cozzi; Marcello Di Valentino; Marcus Katoh; Claudio Marone; Peter Vock; Augusto Gallino
Journal:  Radiology       Date:  2007-08-23       Impact factor: 11.105

6.  Initial results of cardiac imaging at 7 Tesla.

Authors:  C J Snyder; L DelaBarre; G J Metzger; P-F van de Moortele; C Akgun; K Ugurbil; J T Vaughan
Journal:  Magn Reson Med       Date:  2009-03       Impact factor: 4.668

7.  Performance of external and internal coil configurations for prostate investigations at 7 T.

Authors:  Gregory J Metzger; Pierre-Francois van de Moortele; Can Akgun; Carl J Snyder; Steen Moeller; John Strupp; Peter Andersen; Devashish Shrivastava; Tommy Vaughan; Kamil Ugurbil; Gregor Adriany
Journal:  Magn Reson Med       Date:  2010-08-25       Impact factor: 4.668

8.  Study of tumor blood perfusion and its variation due to vascular normalization by anti-angiogenic therapy based on 3D angiogenic microvasculature.

Authors:  Jie Wu; Quan Long; Shixiong Xu; Anwar R Padhani
Journal:  J Biomech       Date:  2009-03-05       Impact factor: 2.712

Review 9.  Non-contrast-enhanced MR imaging of renal artery stenosis at 1.5 tesla.

Authors:  Gregory J Wilson; Jeffrey H Maki
Journal:  Magn Reson Imaging Clin N Am       Date:  2009-02       Impact factor: 2.266

10.  RF shimming for spectroscopic localization in the human brain at 7 T.

Authors:  Hoby P Hetherington; Nikolai I Avdievich; Andrey M Kuznetsov; Jullie W Pan
Journal:  Magn Reson Med       Date:  2010-01       Impact factor: 4.668

View more
  29 in total

Review 1.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

2.  Brain imaging with improved acceleration and SNR at 7 Tesla obtained with 64-channel receive array.

Authors:  Kamil Uğurbil; Edward Auerbach; Steen Moeller; Andrea Grant; Xiaoping Wu; Pierre-Francois Van de Moortele; Cheryl Olman; Lance DelaBarre; Scott Schillak; Jerahmie Radder; Russell Lagore; Gregor Adriany
Journal:  Magn Reson Med       Date:  2019-02-25       Impact factor: 4.668

3.  Numerical and experimental evaluation of RF shimming in the human brain at 9.4 T using a dual-row transmit array.

Authors:  Jens Hoffmann; Gunamony Shajan; Klaus Scheffler; Rolf Pohmann
Journal:  MAGMA       Date:  2013-11-26       Impact factor: 2.310

4.  MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T.

Authors:  Felix P Kuhn; Georg Spinner; Filippo Del Grande; Michael Wyss; Marco Piccirelli; Stefan Erni; Pascal Pfister; Michael Ho; Bert-Ram Sah; Lukas Filli; Dominik A Ettlin; Luigi M Gallo; Gustav Andreisek; Andrei Manoliu
Journal:  Dentomaxillofac Radiol       Date:  2016-12-18       Impact factor: 2.419

5.  Seven-Tesla MRI of the female pelvis.

Authors:  Lale Umutlu; Oliver Kraff; Anja Fischer; Sonja Kinner; Stefan Maderwald; Kai Nassenstein; Felix Nensa; Johannes Grüneisen; Stephan Orzada; Andreas K Bitz; Michael Forsting; Mark E Ladd; Thomas C Lauenstein
Journal:  Eur Radiol       Date:  2013-05-04       Impact factor: 5.315

6.  Simultaneous multislice multiband parallel radiofrequency excitation with independent slice-specific transmit B1 homogenization.

Authors:  Xiaoping Wu; Sebastian Schmitter; Edward J Auerbach; Steen Moeller; Kâmil Uğurbil; Pierre-François Van de Moortele
Journal:  Magn Reson Med       Date:  2013-06-25       Impact factor: 4.668

7.  Mitigating transmit B 1 inhomogeneity in the liver at 7T using multi-spoke parallel transmit RF pulse design.

Authors:  Xiaoping Wu; Sebastian Schmitter; Edward J Auerbach; Kâmil Uğurbil; Pierre-François Van de Moortele
Journal:  Quant Imaging Med Surg       Date:  2014-02

8.  Electrodynamics and radiofrequency antenna concepts for human magnetic resonance at 23.5 T (1 GHz) and beyond.

Authors:  Lukas Winter; Thoralf Niendorf
Journal:  MAGMA       Date:  2016-04-20       Impact factor: 2.310

9.  Measuring renal tissue relaxation times at 7 T.

Authors:  Xiufeng Li; Patrick J Bolan; Kamil Ugurbil; Gregory J Metzger
Journal:  NMR Biomed       Date:  2014-10-23       Impact factor: 4.044

10.  First in-vivo human imaging at 10.5T: Imaging the body at 447 MHz.

Authors:  Xiaoxuan He; M Arcan Ertürk; Andrea Grant; Xiaoping Wu; Russell L Lagore; Lance DelaBarre; Yiğitcan Eryaman; Gregor Adriany; Eddie J Auerbach; Pierre-François Van de Moortele; Kâmil Uğurbil; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2019-12-17       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.