Literature DB >> 20524114

Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws.

Guido Garavaglia1, Anne Lübbeke, Christophe Barea, Constantinos Roussos, Robin Peter, Pierre Hoffmeyer.   

Abstract

Total hip arthroplasty (THA) with well designed cementless acetabular implants has shown excellent results. The purpose of this study was to assess our clinical and radiological outcomes using an uncemented cup. We conducted a prospective cohort study including all consecutive primary THAs performed with the Morscher press-fit cup, an uncemented non-modular acetabular component, between March 1996 and December 1998. Patients were evaluated at ten years with clinical and radiological follow-up, patient satisfaction and questionnaire assessment using the Harris hip score (HHS), Merle d'Aubigné and Postel score, the UCLA score, the 12-item short-form health survey (SF-12) and a visual analog scale. Five hundred sixty-one THAs were performed in 518 patients. At 120 months (± 7.3 months), 303 patients with 335 THAs were still available for follow-up. None of the patients had required cup revision for aseptic loosening. At ten years, the cup survivorship was 98.8% (95% CI 97.4-99.5) with cup revision for any cause as an endpoint. No radiolucencies were seen around the cups, but osteolytic defects involved 21 stems (8.3%). Mean total linear polyethylene wear was 0.9 mm. The Morscher acetabular replacement cup provides excellent results at ten years. There were no revisions for aseptic loosening of the cup, and no osteolytic defects were found around the cup. Patient satisfaction was high and the clinical results were very good.

Entities:  

Mesh:

Year:  2010        PMID: 20524114      PMCID: PMC3167411          DOI: 10.1007/s00264-010-1059-8

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  31 in total

1.  Acetabular revision in total hip replacement with a press-fit cup.

Authors:  R Elke; B Berli; A Wagner; E W Morscher
Journal:  J Bone Joint Surg Br       Date:  2003-11

2.  Nonmodular flexible press-fit cup in primary total hip arthroplasty: 15-year followup.

Authors:  Bernhard J Berli; Gu Ping; Walter Dick; Erwin W Morscher
Journal:  Clin Orthop Relat Res       Date:  2007-08       Impact factor: 4.176

3.  The Morscher Press Fit acetabular component: a nine- to 13-year review.

Authors:  D P Gwynne-Jones; N Garneti; C Wainwright; J A Matheson; R King
Journal:  J Bone Joint Surg Br       Date:  2009-07

4.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

5.  The correlation between the roentgenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties.

Authors:  J P Hodgkinson; P Shelley; B M Wroblewski
Journal:  Clin Orthop Relat Res       Date:  1988-03       Impact factor: 4.176

6.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation.

Authors:  W H Harris
Journal:  J Bone Joint Surg Am       Date:  1969-06       Impact factor: 5.284

7.  A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties.

Authors:  C J Sutherland; A H Wilde; L S Borden; K E Marks
Journal:  J Bone Joint Surg Am       Date:  1982-09       Impact factor: 5.284

8.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

9.  Clinical and radiographic results and wear performance in different generations of a cementless porous-coated acetabular cup.

Authors:  E García-Rey; E García-Cimbrelo
Journal:  Int Orthop       Date:  2007-01-31       Impact factor: 3.075

10.  Long-term deterioration of joint evaluation scores.

Authors:  M A Ritter; A E Thong; K E Davis; M E Berend; J B Meding; P M Faris
Journal:  J Bone Joint Surg Br       Date:  2004-04
View more
  4 in total

1.  Fixation failures of dual mobility cups: a mid-term study of 2601 hip replacements.

Authors:  Philippe Massin; Vincent Orain; Rémi Philippot; Frederic Farizon; Michel Henry Fessy
Journal:  Clin Orthop Relat Res       Date:  2011-12-13       Impact factor: 4.176

Review 2.  Do monoblock cups improve survivorship, decrease wear, or reduce osteolysis in uncemented total hip arthroplasty?

Authors:  Jelle J Halma; H Charles Vogely; Wouter J Dhert; Steven M Van Gaalen; Arthur de Gast
Journal:  Clin Orthop Relat Res       Date:  2013-08-03       Impact factor: 4.176

3.  High survival in young patients using a second generation uncemented total hip replacement.

Authors:  Marcus R Streit; Kerstin Schröder; Matthias Körber; Christian Merle; Tobias Gotterbarm; Volker Ewerbeck; Peter R Aldinger
Journal:  Int Orthop       Date:  2011-11-24       Impact factor: 3.075

4.  Survival of uncemented acetabular monoblock cups: evaluation of 210 hips in the Swedish Hip Arthroplasty Register.

Authors:  Rüdiger J Weiss; Nils P Hailer; André Stark; Johan Kärrholm
Journal:  Acta Orthop       Date:  2012-05-10       Impact factor: 3.717

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.