Literature DB >> 17265006

[Optical performance of multifocal intraocular lenses. Investigation of the Array SA40N vs. Acri. Twin at the "physical eye" according to Reiner and Jacobi].

F K Jacobi1, W Kessler, S Held.   

Abstract

BACKGROUND: Reduced contrast sensitivity, glare disability and insufficient bifocality are the main drawbacks of multifocal intraocular lenses (IOL). The bilateral implantation of diffractive IOL with an asymmetrical light distribution for distance and near focus is an alternative concept that aims to improve the contrast sensitivity and bifocality of conventional multifocal IOL. PATIENTS AND METHODS: The optical performance of monofocal (PhacoFlexII SI40) and multifocal IOL (Array SA40N; Acri. Twin 737D/733D) was quantitatively assessed in 18 healthy probands and qualitatively determined by digital photographic recording using an optical apparatus, the "physical eye", according to Reiner and Jacobi. Vision examination included standard tests of distance and near visual acuity, contrast sensitivity and low contrast visual acuity testing under varying pupil size using a video acuity tester.
RESULTS: Distance visual acuity was significantly superior with the SI40 and distant-dominant 737D compared to the SA40N and near-dominant 733D. At near, the 733D had the best performance. Contrast sensitivity was better with the 737D than the SA40N when both were compared with the SI40. No normal contrast sensitivity could be determined with the 733D because of the optical phenomenon of 'spurious resolution'. Variation in pupil size had less impact on contrast acuity with the Acri. Twin IOL compared to the SI40 and SA40N. Photographic testing revealed better edge contrast with the Acri. Twin than the SA40N.
CONCLUSIONS: The optical performance of multifocal IOL correlates with the properties of physical light distribution. Differences in edge contrast may be discerned using photographic recording.

Entities:  

Mesh:

Year:  2007        PMID: 17265006     DOI: 10.1007/s00347-006-1452-2

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  18 in total

Review 1.  Accommodative intraocular lenses: current status.

Authors:  H Burkhard Dick
Journal:  Curr Opin Ophthalmol       Date:  2005-02       Impact factor: 3.761

2.  [An instrument for projecting visual perception by monofocal and bifocal intraocular lenses].

Authors:  J Reiner
Journal:  Klin Monbl Augenheilkd       Date:  1992-01       Impact factor: 0.700

3.  Pupillary size and responsiveness. Implications for selection of a bifocal intraocular lens.

Authors:  D D Koch; S W Samuelson; E A Haft; L M Merin
Journal:  Ophthalmology       Date:  1991-07       Impact factor: 12.079

4.  [Contrast vision and contrast sensitivity after binocular implantation of multifocal or monofocal intraocular lenses].

Authors:  J Breitkopf; D Eisenmann; F K Jacobi
Journal:  Ophthalmologe       Date:  1997-07       Impact factor: 1.059

Review 5.  [Presbyopia correction using intraocular lenses].

Authors:  M P Holzer; T M Rabsilber; G U Auffarth
Journal:  Ophthalmologe       Date:  2006-08       Impact factor: 1.059

6.  [Functional results with two multifocal intraocular lenses (MIOL). Array SA40 versus Acri.Twin].

Authors:  U Mester; P Dillinger; N Anterist; H Kaymak
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

7.  ["Physical eyes" for evaluating various intraocular lenses for monocular and binocular use].

Authors:  K W Jacobi; J Reiner
Journal:  Klin Monbl Augenheilkd       Date:  1993-12       Impact factor: 0.700

Review 8.  [Multifocal intraocular lenses. A review].

Authors:  G U Auffarth; H B Dick
Journal:  Ophthalmologe       Date:  2001-02       Impact factor: 1.059

9.  [Prospective comparison of 2 multi-focal lens models].

Authors:  A Liekfeld; T Walkow; N Anders; D T Pham; J Wollensak
Journal:  Ophthalmologe       Date:  1998-04       Impact factor: 1.059

10.  Modulation transfer function and pupil size in multifocal and monofocal intraocular lenses in vitro.

Authors:  Takushi Kawamorita; Hiroshi Uozato
Journal:  J Cataract Refract Surg       Date:  2005-12       Impact factor: 3.351

View more
  1 in total

1.  Refractive lens exchange with distance-dominant diffractive bifocal intraocular lens implantation.

Authors:  José F Alfonso; Luis Fernández-Vega; Susana Ortí; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-16       Impact factor: 3.117

  1 in total