Accommodative intraocular lenses: current status.

H Burkhard Dick1.   

Abstract

PURPOSE OF REVIEW: The possibility of using a monofocal IOL with accommodative ability allows refractive cataract surgery with a clearly decreased potential of photic phenomena. Three IOLs of different designs and materials have demonstrated accommodative ability, but the degree of accommodative amplitude has been reported to different extents and variabilities. The plate-haptic CrystaLens has a hinged design that might permit forward movement of the optic as a result of pressure changes in the vitreous cavity. The 1CU has modified haptics that bend in the bag as the lens capsule contracts, which are supposed to cause anterior displacement of the lens optic. With the dual-optic one-piece Synchrony, springlike haptics separate a high-plus anterior lens from a posterior minus lens. With accommodative effort, the capsular bag expands and the springs express kinetic energy, which might allow the optics to separate as the anterior lens moves forward. RECENT
FINDINGS: This article seeks to clarify and distinguish the concepts of true accommodation and pseudo accommodation. Current designs of accommodative IOLs are supposed to work by the focus-shift principle to allow true pseudophakic accommodation. Studies that biometrically assessed optic shift found no or only low amplitudes of forward movement. The amount of forward movement, if present, was highly variable between patients. To date, most studies present psychophysical data for the proof of concept, which alone seems insufficient. Capsule bag performance and posterior capsule opacification with accommodative IOLs seem worse than those with standard intraocular lenses.
SUMMARY: The potential clinical benefits of accommodative IOL technology for both cataract patients and refractive patients may place accommodative IOLs in a competitive position with multifocal IOL technology.

Entities:  

Mesh:

Year:  2005        PMID: 15650575     DOI: 10.1097/00055735-200502000-00004

Source DB:  PubMed          Journal:  Curr Opin Ophthalmol        ISSN: 1040-8738            Impact factor:   3.761


  17 in total

1.  Paraxial analysis of the depth of field of a pseudophakic eye with accommodating intraocular lens.

Authors:  Jit B Ale; Fabrice Manns; Arthur Ho
Journal:  Optom Vis Sci       Date:  2011-07       Impact factor: 1.973

2.  [Presbyopia treatment using a femtosecond laser].

Authors:  M Blum; K Kunert; S Nolte; S Riehemann; M Palme; T Peschel; M Dick; H B Dick
Journal:  Ophthalmologe       Date:  2006-12       Impact factor: 1.059

Review 3.  Restoration of accommodation: surgical options for correction of presbyopia.

Authors:  Adrian Glasser
Journal:  Clin Exp Optom       Date:  2008-05       Impact factor: 2.742

4.  Prediction of accommodative optical response in prepresbyopic subjects using ultrasound biomicroscopy.

Authors:  Viswanathan Ramasubramanian; Adrian Glasser
Journal:  J Cataract Refract Surg       Date:  2015-05       Impact factor: 3.351

Review 5.  Clinical application of accommodating intraocular lens.

Authors:  You-Ling Liang; Song-Bai Jia
Journal:  Int J Ophthalmol       Date:  2018-06-18       Impact factor: 1.779

6.  Evaluation of the performance of accommodating IOLs using a paraxial optics analysis.

Authors:  Jit Ale; Fabrice Manns; Arthur Ho
Journal:  Ophthalmic Physiol Opt       Date:  2009-12-09       Impact factor: 3.117

Review 7.  Axial movement of the dual-optic accommodating intraocular lens for the correction of the presbyopia: optical performance and clinical outcomes.

Authors:  Javier Tomás-Juan; Ane Murueta-Goyena Larrañaga
Journal:  J Optom       Date:  2014-09-22

Review 8.  [Presbyopia correction using intraocular lenses].

Authors:  M P Holzer; T M Rabsilber; G U Auffarth
Journal:  Ophthalmologe       Date:  2006-08       Impact factor: 1.059

9.  [First results with a new aberration correcting bifocal intraocular lens].

Authors:  H Kaymak; U Mester
Journal:  Ophthalmologe       Date:  2007-12       Impact factor: 1.059

10.  Adaptive calibration of dynamic accommodation--implications for accommodating intraocular lenses.

Authors:  Clifton M Schor; Shrikant R Bharadwaj
Journal:  J Refract Surg       Date:  2008-11       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.