Michael Bach1. 1. University Augenklinik Freiburg, Killianstr. 6, 79106 Freiburg, Germany. michael.bach@uni-freiburg.de
Abstract
BACKGROUND: The Freiburg Visual Acuity and Contrast Test (FrACT) has been further developed; it is now available for Macintosh and Windows free of charge at http://www.michaelbach.de/fract.html . The present study sought to reduce the test-retest variability of visual acuity on short runs (18 trials) by post-hoc re-analysis. METHODS: The FrACT employs advanced computer graphics to present Landolt Cs over the full range of visual acuity. The sequence of optotypes presented follows an adaptive staircase procedure, the Best-PEST algorithm. The Best-PEST threshold obtained after 18 trials was compared to the result of a post-hoc re-analysis of the acquired data, where both threshold and slope of the psychometric function were estimated via a maximum-likelihood fit. RESULTS: Testing time was 1.7 min per run on average. Test-retest reproducibility was +/-2 lines (or +/-0.2 logMAR) for a 95% confidence band (using 18 optotype presentations per test run). Post-hoc psychometric fitting reproduced the Best-PEST result within 1%, although the individual slopes varied widely; test-retest reproducibility was not improved. CONCLUSIONS: The FrACT offers advantages over traditional chart testing with respect to objectivity and reliability. The similarity between the results of the Best-PEST vs. post-hoc analysis, fitting both slope and threshold, suggest that there is no disadvantage to the constant slope assumed by Best PEST. Furthermore, since variability was not reduced by post-hoc analysis, for high reliability more trials should be employed than the 18 trials per run used here.
BACKGROUND: The Freiburg Visual Acuity and Contrast Test (FrACT) has been further developed; it is now available for Macintosh and Windows free of charge at http://www.michaelbach.de/fract.html . The present study sought to reduce the test-retest variability of visual acuity on short runs (18 trials) by post-hoc re-analysis. METHODS: The FrACT employs advanced computer graphics to present Landolt Cs over the full range of visual acuity. The sequence of optotypes presented follows an adaptive staircase procedure, the Best-PEST algorithm. The Best-PEST threshold obtained after 18 trials was compared to the result of a post-hoc re-analysis of the acquired data, where both threshold and slope of the psychometric function were estimated via a maximum-likelihood fit. RESULTS: Testing time was 1.7 min per run on average. Test-retest reproducibility was +/-2 lines (or +/-0.2 logMAR) for a 95% confidence band (using 18 optotype presentations per test run). Post-hoc psychometric fitting reproduced the Best-PEST result within 1%, although the individual slopes varied widely; test-retest reproducibility was not improved. CONCLUSIONS: The FrACT offers advantages over traditional chart testing with respect to objectivity and reliability. The similarity between the results of the Best-PEST vs. post-hoc analysis, fitting both slope and threshold, suggest that there is no disadvantage to the constant slope assumed by Best PEST. Furthermore, since variability was not reduced by post-hoc analysis, for high reliability more trials should be employed than the 18 trials per run used here.
Authors: Richard J Dennis; Jeremy M A Beer; J Bruce Baldwin; Douglas J Ivan; Frank J Lorusso; William T Thompson Journal: Optom Vis Sci Date: 2004-07 Impact factor: 1.973
Authors: Edith V Sullivan; Ty Brumback; Susan F Tapert; Rosemary Fama; Devin Prouty; Sandra A Brown; Kevin Cummins; Wesley K Thompson; Ian M Colrain; Fiona C Baker; Michael D De Bellis; Stephen R Hooper; Duncan B Clark; Tammy Chung; Bonnie J Nagel; B Nolan Nichols; Torsten Rohlfing; Weiwei Chu; Kilian M Pohl; Adolf Pfefferbaum Journal: Neuropsychology Date: 2016-01-11 Impact factor: 3.295
Authors: Lauren N Ayton; Joseph F Rizzo; Ian L Bailey; August Colenbrander; Gislin Dagnelie; Duane R Geruschat; Philip C Hessburg; Chris D McCarthy; Matthew A Petoe; Gary S Rubin; Philip R Troyk Journal: Transl Vis Sci Technol Date: 2020-07-16 Impact factor: 3.283