Literature DB >> 17197321

Delayed fracture of a ceramic insert with modern ceramic total hip replacement.

Byung-Woo Min1, Kwang-Soon Song, Chul-Hyung Kang, Ki-Cheol Bae, Ye-Yeon Won, Kwon-Yong Lee.   

Abstract

We report a case of ceramic liner fracture in a 34-year-old man that occurred 1 year 9 months after total hip arthroplasty with a BiCONTACT (Aesculap, Tuttlingen, Germany) ceramic-on-ceramic prosthesis. The ceramic liner was found within the metal shell in 4 large pieces and multiple small fragments in the peripheral portions. Its condition indicated that the possible mechanism of late ceramic liner chip fracture was repeated episodes of impingement between the prosthetic neck and the edge of the ceramic liner. Squatting, kneeling, and sitting cross-legged caused impingement. These positions are more common in Asian populations than in Western populations. After the joint was thoroughly irrigated, a new modular ceramic liner and a 28-mm ceramic head were implanted.

Entities:  

Mesh:

Year:  2006        PMID: 17197321     DOI: 10.1016/j.arth.2005.12.012

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  16 in total

1.  Clinical results of posterior cruciate ligament retaining TKA with alumina ceramic condylar prosthesis: comparison to Co-Cr alloy prosthesis.

Authors:  Tokifumi Majima; Kazunori Yasuda; Hidenobu Tago; Yoshimitu Aoki; Akio Minami
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-11-03       Impact factor: 4.342

Review 2.  Impingement and dislocation in total hip arthroplasty: mechanisms and consequences.

Authors:  Thomas D Brown; Jacob M Elkins; Douglas R Pedersen; John J Callaghan
Journal:  Iowa Orthop J       Date:  2014

3.  Mid-term clinical results of alumina medial pivot total knee arthroplasty.

Authors:  Takahiro Iida; Yukihide Minoda; Yoshinori Kadoya; Yoshio Matsui; Akio Kobayashi; Hiroyoshi Iwaki; Mitsuhiko Ikebuchi; Taku Yoshida; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-05       Impact factor: 4.342

4.  Imaging of ceramic liner fractures in total hip arthroplasty: the value of CT.

Authors:  Yoshimi Endo; Lisa Renner; Tom Schmidt-Braekling; Douglas N Mintz; Friedrich Boettner
Journal:  Skeletal Radiol       Date:  2015-03-07       Impact factor: 2.199

5.  Non-traumatic Ceramic Head Fracture in Total Hip Arthroplasty with Ceramic-on-Ceramic Articulation at Postoperative 16th Years.

Authors:  Onur Kocadal; Turhan Ozler; Alp Er Tunga Bolukbasi; Faik Altintas
Journal:  Hip Pelvis       Date:  2019-05-30

6.  Fracture propagation propensity of ceramic liners during impingement-subluxation: a finite element exploration.

Authors:  Jacob M Elkins; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  J Arthroplasty       Date:  2011-08-19       Impact factor: 4.757

7.  THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial.

Authors:  William G Hamilton; James P McAuley; Douglas A Dennis; Jeffrey A Murphy; Thomas J Blumenfeld; Joel Politi
Journal:  Clin Orthop Relat Res       Date:  2009-09-19       Impact factor: 4.176

8.  Do obesity and/or stripe wear increase ceramic liner fracture risk? An XFEM analysis.

Authors:  Jacob M Elkins; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

Review 9.  [The problem of fractures of ceramic heads. What should be done?].

Authors:  H R Dürr
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

Review 10.  Fracture of ceramic bearing surfaces following total hip replacement: a systematic review.

Authors:  Francesco Traina; Marcello De Fine; Alberto Di Martino; Cesare Faldini
Journal:  Biomed Res Int       Date:  2013-06-13       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.