Literature DB >> 17982743

Clinical results of posterior cruciate ligament retaining TKA with alumina ceramic condylar prosthesis: comparison to Co-Cr alloy prosthesis.

Tokifumi Majima1, Kazunori Yasuda, Hidenobu Tago, Yoshimitu Aoki, Akio Minami.   

Abstract

In a prospective study, 194 knees undergoing total knee arthroplasty (110 knees with alumina ceramic prostheses; 84 knees with Co-Cr alloy prostheses) were clinically and radiologically evaluated. Average follow-up period was 66 months (36-124 months). Average age at the time of surgery was 66 years. In the ceramic prostheses, two revision surgeries were performed because of breakage of the tibial tray and late infection, whereas two revisions of the Co-Cr alloy prostheses were carried out due to loosening and late infection. In the other patients, there were no significant differences in clinical parameters (HSS knee score and range of motion) between the two prostheses. In radiological evaluation, we could not find any radiolucent lines around the femoral ceramic component while radiolucency was present in three knees (3.6%) around the Co-Cr femoral component. Beneath the tibial tray, three knees (2.7%) showed a radiolucent line around the former prosthesis while eight knees (9.5%) demonstrated a radiolucent line around the latter prosthesis. Chi-square tests showed a significant difference in the occurrence of radiolucent line around both of the femoral and tibial prosthesis. This study demonstrated that clinical results of the alumina ceramic PCL retaining total knee prosthesis are comparable to the standard Co-Cr alloy PCL retaining total knee prosthesis. Although we could not draw any conclusions regarding the superiority of the ceramic prosthesis with respect to UHMWPE wear and long-term survivorship, this report encouraged a long-term follow-up study on ceramic prostheses.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17982743     DOI: 10.1007/s00167-007-0435-4

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  17 in total

1.  The Kinemax total knee arthroplasty. Nine years' experience.

Authors:  D L Back; S R Cannon; A Hilton; M J Bankes; T W Briggs
Journal:  J Bone Joint Surg Br       Date:  2001-04

2.  The Bisurface total knee replacement: a unique design for flexion. Four-to-nine-year follow-up study.

Authors:  M Akagi; T Nakamura; Y Matsusue; T Ueo; K Nishijyo; E Ohnishi
Journal:  J Bone Joint Surg Am       Date:  2000-11       Impact factor: 5.284

Review 3.  The spectrum of prosthesis design for primary total knee arthroplasty.

Authors:  Michael A Mont; Robert E Booth; Richard S Laskin; James B Stiehl; Merrill A Ritter; Steven A Stuchin; Amar D Rajadhyaksha
Journal:  Instr Course Lect       Date:  2003

4.  Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis.

Authors:  R S Nizard; L Sedel; P Christel; A Meunier; M Soudry; J Witvoet
Journal:  Clin Orthop Relat Res       Date:  1992-09       Impact factor: 4.176

5.  Long-term effects of alumina components in total hip prostheses.

Authors:  J M Dorlot
Journal:  Clin Orthop Relat Res       Date:  1992-09       Impact factor: 4.176

6.  Delayed fracture of a ceramic insert with modern ceramic total hip replacement.

Authors:  Byung-Woo Min; Kwang-Soon Song; Chul-Hyung Kang; Ki-Cheol Bae; Ye-Yeon Won; Kwon-Yong Lee
Journal:  J Arthroplasty       Date:  2006-06-21       Impact factor: 4.757

7.  The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system.

Authors:  F C Ewald
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

8.  New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminium oxide ceramin/metal.

Authors:  M Semlitsch; M Lehmann; H Weber; E Doerre; H G Willert
Journal:  J Biomed Mater Res       Date:  1977-07

9.  Alumina versus polyethylene in total knee arthroplasty.

Authors:  H Oonishi; M Aono; N Murata; S Kushitani
Journal:  Clin Orthop Relat Res       Date:  1992-09       Impact factor: 4.176

Review 10.  Biocompatibility of surgical-grade dense polycrystalline alumina.

Authors:  P S Christel
Journal:  Clin Orthop Relat Res       Date:  1992-09       Impact factor: 4.176

View more
  11 in total

1.  Long-term survival analysis of posterior cruciate-retaining total knee arthroplasty.

Authors:  Lin Guo; Liu Yang; Jean Louis Briard; Xiao-jun Duan; Fu-you Wang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-10       Impact factor: 4.342

2.  [Total knee replacement with ceramic femoral components: a national prospective multicenter study of clinical and radiological outcomes].

Authors:  P Bergschmidt; C Lohmann; D Ganzer; R Bader; S Finze; G Kundt; C Hauzeur; C Lukas; W Rüther; W Mittelmeier
Journal:  Orthopade       Date:  2011-03       Impact factor: 1.087

3.  In-vivo kinematics of high-flex posterior-stabilized total knee prosthesis designed for Asian populations.

Authors:  Toshifumi Watanabe; Takeshi Muneta; Hideyuki Koga; Masafumi Horie; Tomomasa Nakamura; Koji Otabe; Yusuke Nakagawa; Mai Katakura; Ichiro Sekiya
Journal:  Int Orthop       Date:  2016-04-02       Impact factor: 3.075

4.  Mid-term clinical results of alumina medial pivot total knee arthroplasty.

Authors:  Takahiro Iida; Yukihide Minoda; Yoshinori Kadoya; Yoshio Matsui; Akio Kobayashi; Hiroyoshi Iwaki; Mitsuhiko Ikebuchi; Taku Yoshida; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-05       Impact factor: 4.342

5.  Total knee arthroplasty in patients with hypersensitivity to metals.

Authors:  Massimo Innocenti; Christian Carulli; Fabrizio Matassi; Anna Maria Carossino; Maria Luisa Brandi; Roberto Civinini
Journal:  Int Orthop       Date:  2014-01-04       Impact factor: 3.075

6.  A soluble factor (EMMPRIN) in exudate influences knee motion after total arthroplasty.

Authors:  Jun Onodera; Shin Onodera; Eiji Kondo; Tomoko Betsuyaku; Kazunori Yasuda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-12-17       Impact factor: 4.342

7.  Comparative Study of Clinical and Radiological Outcomes of Unconstrained Bicondylar Total Knee Endoprostheses with Anti-allergic Coating.

Authors:  Philipp Bergschmidt; Rainer Bader; Susanne Finze; Christoph Schulze; Guenther Kundt; Wolfram Mittelmeier
Journal:  Open Orthop J       Date:  2011-10-07

8.  First clinical study of a novel complete metal-free ceramic total knee replacement system.

Authors:  E Meier; K Gelse; K Trieb; M Pachowsky; F F Hennig; A Mauerer
Journal:  J Orthop Surg Res       Date:  2016-02-08       Impact factor: 2.359

9.  Ceramic femoral components in total knee arthroplasty - two year follow-up results of an international prospective multi-centre study.

Authors:  Philipp Bergschmidt; Rainer Bader; Dirk Ganzer; Christian Hauzeur; Christoph Lohmann; Wolfgang Rüther; Domenico Tigani; Nicola Rani; Fernando Lopez Prats; Claudio Zorzi; Vincenzo Madonna; Stefano Rigotti; Francesco Benazzo; Stefano Marco Paolo Rossi; Guenther Kundt; Hans Rudolf Bloch; Wolfram Mittelmeier
Journal:  Open Orthop J       Date:  2012-04-20

10.  Local Biological Reactions and Pseudotumor-Like Tissue Formation in relation to Metal Wear in a Murine In Vivo Model.

Authors:  Alexander C Paulus; Kathrin Ebinger; Xiangyun Cheng; Sandra Haßelt; Patrick Weber; J Philippe Kretzer; Rainer Bader; Sandra Utzschneider
Journal:  Biomed Res Int       Date:  2019-10-29       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.