Literature DB >> 21855277

Fracture propagation propensity of ceramic liners during impingement-subluxation: a finite element exploration.

Jacob M Elkins1, Douglas R Pedersen, John J Callaghan, Thomas D Brown.   

Abstract

Although improvements in materials engineering have greatly reduced fracture rates in ceramic femoral heads, concerns still exist for liners. Ceramics are vulnerable to fracture due to impact and from stress concentrations (point and line loading) such as those associated with impingement-subluxation. Thus, ceramic cup fracture propensity is presumably very sensitive to surgical cup positioning. A novel fracture mechanics finite element formulation was developed to identify cup orientations most susceptible to liner fracture propagation for several impingement-prone patient maneuvers. Other factors being equal, increased cup inclination and increased anteversion were found to elevate fracture risk. Squatting, stooping, and leaning shoe-tie maneuvers were associated with the highest fracture risk. These results suggest that fracture risk can be reduced by surgeons' decreasing cup abduction and by patients' avoiding of specific activities. Copyright Â
© 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21855277      PMCID: PMC3246563          DOI: 10.1016/j.arth.2011.06.023

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  25 in total

1.  Mechanical performance of ceramic acetabular liners under impact conditions.

Authors:  Suzanne A Maher; Joseph D Lipman; Luke J Curley; Michael Gilchrist; Timothy M Wright
Journal:  J Arthroplasty       Date:  2003-10       Impact factor: 4.757

2.  Hard-on-hard total hip impingement causes extreme contact stress concentrations.

Authors:  Jacob M Elkins; Megan K O'Brien; Nicholas J Stroud; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

3.  [Fracture load of ceramic ball heads of hip joint prostheses].

Authors:  E Dörre; H G Richter; G Willmann
Journal:  Biomed Tech (Berl)       Date:  1991-12       Impact factor: 1.411

4.  Axisymmetric mechanical analysis of ceramic heads for total hip replacement.

Authors:  A O Andrisano; E Dragoni; A Strozzi
Journal:  Proc Inst Mech Eng H       Date:  1990       Impact factor: 1.617

5.  Fatigue behavior of zirconia hip joint heads: experimental results and finite element analysis.

Authors:  J M Drouin; B Cales; J Chevalier; G Fantozzi
Journal:  J Biomed Mater Res       Date:  1997-02

6.  Friction of total hip replacements with different bearings and loading conditions.

Authors:  Claire Brockett; Sophie Williams; Zhongmin Jin; Graham Isaac; John Fisher
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2007-05       Impact factor: 3.368

7.  Survival analysis of an uncemented ceramic acetabular component in total hip replacement.

Authors:  K Knahr; M Böhler; P Frank; H Plenk; M Salzer
Journal:  Arch Orthop Trauma Surg       Date:  1987

8.  [Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications].

Authors:  P Boutin
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1972 Apr-May

9.  Undetected fracture of an alumina ceramic on ceramic hip prosthesis.

Authors:  Elhadi Sariali; Todd Stewart; Patrick Mamoudy; Zhongmin Jin; John Fisher
Journal:  J Arthroplasty       Date:  2009-07-04       Impact factor: 4.757

10.  Fractures of ceramic bearings: history and present status.

Authors:  Didier Hannouche; Christophe Nich; Pascal Bizot; Alain Meunier; Rémi Nizard; Laurent Sedel
Journal:  Clin Orthop Relat Res       Date:  2003-12       Impact factor: 4.176

View more
  4 in total

Review 1.  Impingement and dislocation in total hip arthroplasty: mechanisms and consequences.

Authors:  Thomas D Brown; Jacob M Elkins; Douglas R Pedersen; John J Callaghan
Journal:  Iowa Orthop J       Date:  2014

2.  Do obesity and/or stripe wear increase ceramic liner fracture risk? An XFEM analysis.

Authors:  Jacob M Elkins; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

3.  Effect of microseparation on contact mechanics in metal-on-metal hip replacements-A finite element analysis.

Authors:  Feng Liu; Sophie Williams; John Fisher
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2014-11-05       Impact factor: 3.368

4.  Effect of an edge at cup rim on contact stress during micro-separation in ceramic-on-ceramic hip joints.

Authors:  Feng Liu; John Fisher
Journal:  Tribol Int       Date:  2017-09       Impact factor: 4.872

  4 in total