Literature DB >> 17153413

X-ray spectrum optimization of full-field digital mammography: simulation and phantom study.

Philipp Bernhardt1, Thomas Mertelmeier, Martin Hoheisel.   

Abstract

In contrast to conventional analog screen-film mammography new flat detectors have a high dynamic range and a linear characteristic curve. Hence, the radiographic technique can be optimized independently of the receptor exposure. It can be exclusively focused on the improvement of the image quality and the reduction of the patient dose. In this paper we measure the image quality by a physical quantity, the signal difference-to-noise ratio (SDNR), and the patient risk by the average glandular dose (AGD). Using these quantities, we compare the following different setups through simulations and phantom studies regarding the detection of microcalcifications and tumors for different breast thicknesses and breast compositions: Monochromatic radiation, three different anode/filter combinations: Molybdenum/molybdenum (Mo/Mo), molybdenum/rhodium (Mo/Rh), and tungsten/rhodium (W/Rh), different filter thicknesses, use of anti-scatter grids, and different tube voltages. For a digital mammography system based on an amorphous selenium detector it turned out that, first, the W/Rh combination is the best choice for all detection tasks studied. Second, monochromatic radiation can further reduce the AGD by a factor of up to 2.3, maintaining the image quality in comparison with a real polychromatic spectrum of an x-ray tube. And, third, the use of an anti-scatter grid is only advantageous for breast thicknesses larger than approximately 5 cm.

Entities:  

Mesh:

Year:  2006        PMID: 17153413     DOI: 10.1118/1.2351951

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  17 in total

1.  A technique optimization protocol and the potential for dose reduction in digital mammography.

Authors:  Nicole T Ranger; Joseph Y Lo; Ehsan Samei
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

2.  Contrast-enhanced dual energy mammography with a novel anode/filter combination and artifact reduction: a feasibility study.

Authors:  Thomas Knogler; Peter Homolka; Mathias Hörnig; Robert Leithner; Georg Langs; Martin Waitzbauer; Katja Pinker-Domenig; Sabine Leitner; Thomas H Helbich
Journal:  Eur Radiol       Date:  2015-09-15       Impact factor: 5.315

3.  Tomosynthesis and contrast-enhanced digital mammography: recent advances in digital mammography.

Authors:  Felix Diekmann; Ulrich Bick
Journal:  Eur Radiol       Date:  2007-07-28       Impact factor: 5.315

4.  Dose reduction and its influence on diagnostic accuracy and radiation risk in digital mammography: an observer performance study using an anthropomorphic breast phantom.

Authors:  T Svahn; B Hemdal; M Ruschin; D P Chakraborty; I Andersson; A Tingberg; S Mattsson
Journal:  Br J Radiol       Date:  2007-07       Impact factor: 3.039

5.  Optimization of exposure parameters in full field digital mammography.

Authors:  Mark B Williams; Priya Raghunathan; Mitali J More; J Anthony Seibert; Alexander Kwan; Joseph Y Lo; Ehsan Samei; Nicole T Ranger; Laurie L Fajardo; Allen McGruder; Sandra M McGruder; Andrew D A Maidment; Martin J Yaffe; Aili Bloomquist; Gordon E Mawdsley
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

6.  Investigation of the effect of anode/filter materials on the dose and image quality of a digital mammography system based on an amorphous selenium flat panel detector.

Authors:  P Baldelli; N Phelan; G Egan
Journal:  Br J Radiol       Date:  2009-12-17       Impact factor: 3.039

7.  Clinical dose performance of full field digital mammography in a breast screening programme.

Authors:  J B McCullagh; P Baldelli; N Phelan
Journal:  Br J Radiol       Date:  2011-05-17       Impact factor: 3.039

8.  Modeling the effect of tilting, passive leg exercise, and functional electrical stimulation on the human cardiovascular system.

Authors:  Amirehsan Sarabadani Tafreshi; Jan Okle; Verena Klamroth-Marganska; Robert Riener
Journal:  Med Biol Eng Comput       Date:  2017-02-10       Impact factor: 2.602

9.  Towards standardization of x-ray beam filters in digital mammography and digital breast tomosynthesis: Monte Carlo simulations and analytical modelling.

Authors:  Suman Shrestha; Srinivasan Vedantham; Andrew Karellas
Journal:  Phys Med Biol       Date:  2017-01-11       Impact factor: 3.609

Review 10.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.