A skew-slit collimator for small-animal SPECT.

Gengsheng L Zeng1.   

Abstract

UNLABELLED: The main objective of this work was the development of a skew-slit collimator for small-animal SPECT to replace the state-of-the-art multipinhole collimator.
METHODS: A pinhole forms a cone-beam imaging geometry. If the collimator rotates around the object in a circular orbit, the projection measurements acquired by the cone-beam imaging geometry are incomplete and not enough for artifact-free image reconstruction. The severity of the artifact is proportional to the cone angle of the pinhole in the direction of the axis of rotation. Multipinhole geometry can greatly reduce the data-insufficiency artifacts; however, image magnification is sacrificed. By transforming a pinhole into a pair of skewed slits, we are able to use a large cone angle in the transaxial direction to increase image magnification and a small cone angle in the direction of the axis of rotation to reduce data-insufficiency artifacts. This transformation is achieved by placing a vertical slit (i.e., the slit is parallel to the axis of rotation) close to the object and placing a horizontal slit farther out. Similar to the multipinhole collimator, we also propose a multiple-skew-slit collimator that has a single vertical slit and several horizontal slits.
RESULTS: Computer simulations were performed to verify the working principle of the skew-slit collimator. A prototype multiple-skew-slit collimator was fabricated, and phantom experiments were performed on a SPECT system. The smallest channels (of 0.75-mm diameter) in the phantom were clearly separated in the reconstructed image.
CONCLUSION: This study suggests a novel technology in small-animal SPECT to replace the multipinhole collimator, resulting in significantly reduced image artifacts and increased transaxial resolution. A physical multiple-skew-slit system was built and tested. Compared with the multipinhole system, the multiple-skew-slit system has a larger image magnification in the transaxial direction and thus has better image resolution.

Entities:  

Mesh:

Year:  2008        PMID: 19008286      PMCID: PMC2678834          DOI: 10.2967/jnmt.108.055582

Source DB:  PubMed          Journal:  J Nucl Med Technol        ISSN: 0091-4916


  10 in total

1.  Slit slat collimator optimization with respect to MTF.

Authors:  A Kamali-Asl; S Sarkar; M Shahriari; H Agha-Hosseini
Journal:  Appl Radiat Isot       Date:  2005-03       Impact factor: 1.513

2.  An analytical algorithm for skew-slit collimator SPECT with uniform attenuation correction.

Authors:  Qiulin Tang; Gengsheng L Zeng; Qiu Huang
Journal:  Phys Med Biol       Date:  2006-11-09       Impact factor: 3.609

3.  An analytical algorithm for skew-slit imaging geometry with nonuniform attenuation correction.

Authors:  Qiu Huang; Gengsheng L Zeng
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

4.  On-axis sensitivity and resolution of a slit-slat collimator.

Authors:  Scott D Metzler; Roberto Accorsi; John R Novak; Ahmet S Ayan; Ronald J Jaszczak
Journal:  J Nucl Med       Date:  2006-11       Impact factor: 10.057

5.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

6.  Verification of the sensitivity and resolution dependence on the incidence angle for slit-slat collimation.

Authors:  J R Novak; A S Ayan; R Accorsi; S D Metzler
Journal:  Phys Med Biol       Date:  2008-01-23       Impact factor: 3.609

7.  Derivation and validation of a sensitivity formula for slit-slat collimation.

Authors:  R Accorsi; J R Novak; A S Ayan; S D Metzler
Journal:  IEEE Trans Med Imaging       Date:  2008-05       Impact factor: 10.048

8.  U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice.

Authors:  Freek J Beekman; Frans van der Have; Brendan Vastenhouw; Annemarie J A van der Linden; Peter P van Rijk; J Peter H Burbach; Marten P Smidt
Journal:  J Nucl Med       Date:  2005-07       Impact factor: 10.057

9.  EM reconstruction algorithms for emission and transmission tomography.

Authors:  K Lange; R Carson
Journal:  J Comput Assist Tomogr       Date:  1984-04       Impact factor: 1.826

10.  Evaluation of novel whole-body high-resolution rodent SPECT (Linoview) based on direct acquisition of linogram projections.

Authors:  Stephan Walrand; François Jamar; Marion de Jong; Stanislas Pauwels
Journal:  J Nucl Med       Date:  2005-11       Impact factor: 10.057

  10 in total
  7 in total

1.  Analytic derivation of pinhole collimation sensitivity for a general source model using spherical harmonics.

Authors:  Yu-Sheng Li; James E Oldendick; Wei Chang
Journal:  Phys Med Biol       Date:  2010-04-19       Impact factor: 3.609

2.  High-Resolution Anamorphic SPECT Imaging.

Authors:  Heather L Durko; Harrison H Barrett; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2014-06       Impact factor: 1.679

3.  Adaptive SPECT imaging with crossed-slit apertures.

Authors:  Heather L Durko; Lars R Furenlid
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-08-17

4.  High-resolution, anamorphic, adaptive small-animal SPECT imaging with silicon double-sided strip detectors.

Authors:  Heather L Durko; Todd E Peterson; Harrison H Barrett; Lars R Furenlid
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011-08-21

Review 5.  Advances in pinhole and multi-pinhole collimators for single photon emission computed tomography imaging.

Authors:  Jalil Pirayesh Islamian; AhmadReza Azazrm; Babak Mahmoudian; Esmail Gharapapagh
Journal:  World J Nucl Med       Date:  2015 Jan-Apr

6.  Monte carlo study of the effect of collimator thickness on T-99m source response in single photon emission computed tomography.

Authors:  Jalil Pirayesh Islamian; Mohammad Taghi Bahreyni Toossi; Mahdi Momennezhad; Seyyed Rasoul Zakavi; Ramin Sadeghi; Michael Ljungberg
Journal:  World J Nucl Med       Date:  2012-05

7.  Design Study of an Ultrahigh Resolution Brain SPECT System Using a Synthetic Compound-Eye Camera Design With Micro-Slit and Micro-Ring Apertures.

Authors:  Elena Maria Zannoni; Can Yang; Ling-Jian Meng
Journal:  IEEE Trans Med Imaging       Date:  2021-11-30       Impact factor: 10.048

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.